detailssystemx

systemx  时间:2021-03-28  阅读:()
IBMFlashSystem720andIBMFlashSystem8201IBMFlashSystem720andIBMFlashSystem820IBMRedbooksProductGuideIBMFlashSystem720andIBMFlashSystem820storagesystemsdeliverhighperformance,efficiency,andreliabilityforsharedenterprisestorageenvironments,helpingclientsaroundtheworldaddressperformanceissueswiththeirmostimportantapplicationsandinfrastructure.
Thesestoragesystemscaneithercomplementorreplacetraditionalharddrivearraysinmanyapplications,includingonlinetransactionprocessing(OLTP),businessintelligence(BI),onlineanalyticalprocessing(OLAP),virtualdesktopinfrastructures,high-performancecomputing,andcontentdeliverysolutions(suchascloudstorageandvideoondemand).
Asstandardsharedprimarydatastoragedevices,FlashSystem720andFlashSystem820storagesystemsdeliverperformancebeyondthatofmosttraditionalarrays,eventhosethatincorporateSSDsorotherflashtechnology.
ThesestoragesystemscanalsobeusedasthetoptierofstoragealongsidetraditionalarraysintieredstoragearchitecturessuchastheIBMEasyTierfunctionalityavailableinIBMSystemStorageSANVolumeControllerorIBMStorwizeV7000storagevirtualizationplatforms.
Basedonsinglelevelcell(SLC)flash,FlashSystem720istargetedtowrite-heavyenterpriseworkloads;enterprisemultilevelcell(eMLC)flash-basedFlashSystem820istargetedtoread-heavyworkloads,whereworkloadisdistributedacrossmultipleservers.
Figure1showsFlashSystem720andFlashSystem820.
Figure1.
FlashSystem720andFlashSystem820DidyouknowIBMFlashSystemstoragesystemsdeliverover500,000readIOPSandupto5GBpsbandwidthwithlessthan100microsecondslatency,whiletheyprovideupto24TBoftotalusablecapacityorupto20TBof2DFlashRAIDprotecteddatastoragejustin1Uofrackspace.
FlashSystem720andFlashSystem820featuremissioncriticalavailabilityandreliability,andmultiplelayersofdatacorrection,chipredundancy,andredundanthotswapcomponents.
IBMFlashSystem720andIBMFlashSystem8202KeyfeaturesIBMFlashSystemstoragesystemsdeliveradvancedperformance,scalability,reliability,security,andenergy-efficiencyfeatures.
FlashSystem720andFlashSystem820storagesystemsaretheappropriatechoiceformissioncriticalenterpriseenvironmentswiththefollowingcharacteristics:highstorageperformancerequirements,suchaslowlatency(microsecondsasopposedtomilliseconds),highbandwidth(gigabytespersecond),orhighIOPS(hundredsofthousandsofI/Ooperationspersecond).
ScalabilityandperformanceTheFlashSystemstoragesystemsoffernumerousfeaturestoboostperformanceandimprovescalability:FlashSystemstoragesystemscanprovidemorethan500,000IOPSandupto5GBpsbandwidthforzstorageI/O-intensiveenterpriseworkloads.
FlashSystem820canscaleupto24TBofstoragecapacity,whileFlashSystem720supportsuptoz12TB.
Asingle42Urackcontaining421UFlashSystemstoragesystemscanprovideupto840TBofzprotectedstoragewithmorethan20,000,000IOPSandupto210GBpsbandwidth.
FlashSystemstoragesystemsfeatureoneoftheindustry'shighestflashcapacitydensitymetricz(usableGBperrackspace)andperformancedensitymetrics(IOPSandbandwidthperrackspace).
FlashSystemstoragesystemssupportupto1,024logicalvolumes.
zFlashSystemstoragesystemsofferchoiceof8GbFibreChannelor40GbQDRInfiniBandzconnectivitytomatchtheperformanceofmostdemandingI/Ointensiveapplications.
AvailabilityandserviceabilityTheFlashSystemstoragesystemsprovidemanyfeaturestosimplifyserviceabilityandincreasesystemuptime:FlashSystemstoragesystemsuseoverprovisioningandadvancedwearlevelingtechniquestozdramaticallyimprovewriteenduranceoftheflashmodulestoextendtheirlifetime.
FlashSystem720andFlashSystem820offermultiplelayersofdataprotection(ECC,VariableStripzRAID,and2DFlashRAID)topreventanunplannedoutageincaseofaflashchipormodulefailure.
FlashSystem720andFlashSystem820supporthot-swapflashmoduleswhichallowstoreplacethezfailedmodulewithoutserviceinterruptiontoeliminateplanneddowntime.
FlashSystemstoragesystemsoffertworedundanthot-swappowersuppliesandeightdual-motorznon-hot-swapredundantfanstoprovidecost-efficientavailabilityforapplications.
Easy-to-readLCDdisplayindicatessystemerrorstoleadthetechniciantofailed(orfailing)zcomponents.
Thispanelsimplifiesservicingandspeedsupproblemresolution,helpingimprovesystemavailability.
ThreeN+1redundantbatterieshelppreventdatalossbybackingupdatainRAMbuffersallowingzthemtobewrittentoaflashmoduleincaseofpowerfailure.
Twobuilt-inredundantmanagementmodulesinanactive-passiveconfigurationcontinuouslymonitorzsystemparameters,triggersalerts,andperformsrecoveryactionsincaseoffailure,tominimizedowntime.
One-yearcustomerreplaceableunitandon-sitelimitedwarranty,nextbusinessday9x5.
Optionalzserviceupgradesavailable.
IBMFlashSystem720andIBMFlashSystem8203ManageabilityandsecurityPowerfulsystemsmanagementfeaturessimplifylocalandremotemanagementoftheFlashSystemstoragesystems:FlashSystemstoragesystemshaveabuilt-inLCDdisplayallowingtoperformbasicconfiguration,zmanagement,andmonitoringtasks,simplifyingadministration.
FlashSystemstoragesystemsincludeamanagementmoduletomonitorserveravailabilityandzperformremotemanagement.
Themanagementmoduleprovidesextensivesecurityfeatures,includingrole-baseduserzauthenticationandaccesscontrol,LDAPsupport,andSSHprotocolforsecureremotesystemsmanagement.
LUNmaskingfeatureallowstocontrolaccesstoalogicalvolumefromthehostsidetopreventzunauthorizeddataaccessandmodification.
EnergyefficiencyTheFlashSystemstoragesystemsofferthefollowingenergy-efficiencyfeaturestosaveenergy,reduceoperationalcosts,increaseenergyavailability,andcontributetoagreenenvironment:Energy-efficientflashcomponentshelploweroperationalcosts.
zFlashSystemstoragesystemsofferoneofindustry'sbestIOPSperwattratioenablinggreaterenergyzsavings.
FlashSystemstoragesystemsusehexagonalventilationholes,apartofIBMCalibratedVectoredzCoolingtechnology.
Hexagonalholescanbegroupedmoredenselythanroundholes,providingmoreefficientairflowthroughthesystem.
IBMFlashSystem720andIBMFlashSystem8204LocationsofkeycomponentsandconnectorsFigure2showstheinternalcomponentsoftheFlashSystemunit.
Figure2.
InternalviewoftheFlashSystemunitFigure3showstherearoftheFlashSystemunitwiththeFibreChannelinterfaces.
Figure3.
RearviewoftheFlashSystemunitwiththeFibreChannelinterfacesFigure4showstherearoftheFlashSystemunitwiththeInfiniBandinterfaces.
Figure4.
RearviewoftheFlashSystemunitwiththeInfiniBandinterfacesIBMFlashSystem720andIBMFlashSystem8205SpecificationsTable1liststhespecifications.
Table1.
SpecificationsSpecificationFlashSystem720FlashSystem820Formfactor1Urack-mountedunitFlashmodulequantity12(10+1+1)FlashmoduletypeSinglelevelcell(SLC)Enterprisemultilevelcell(eMLC)FlashmodulecapacitySingle-density(SD):500GBDouble-density(DD):1TBSingle-density(SD):1TBDouble-density(DD):2TBMaximumcapacityRAID0orJBOF:6TB(SD)or12TB(DD)RAID5:5TB(SD)or10TB(DD)RAID0orJBOF:12TB(SD)or24TB(DD)RAID5:10TB(SD)or20TB(DD)FlashmoduleprotectionOverprovisioning,wearleveling,CRCchecksum,ECC,andmodule-levelVariableStripeRAID(standard);2DFlashRAID(optional,pre-selected)RAIDsupportNoRAID(JBOFmode);RAID0acrossflashmodules;optionalRAID5withhotspareacrossflashmodules(2DFlashRAID)Hostinterfaces4x8GbFibreChannel(FC)or4x40GbQDRInfiniBandReadIOPS*525,000525,000WriteIOPS*400,000280,000Readbandwidth**3.
3GBps(FC);5GBps(InfiniBand)3.
3GBps(FC);5GBps(InfiniBand)Writebandwidth**3.
3GBps(FC);4GBps(InfiniBand)2.
8GBps(FC);2.
8GBps(InfiniBand)Readlatency100s110sWritelatency25s25sSystemsmanagementLCDdisplaywithfourcontrolbuttons;twomanagementmodulesCoolingEightredundantnon-hot-swapfans;eachfanhastwomotorsPowersupplyTworedundanthot-swap100-240Vacauto-sensingpowersuppliesInputpower350W300WHeatdissipation1194BTU/hr1023BTU/hrHot-swappartsFlashmodules,powersuppliesSecurityfeaturesRole-basedusersecurity,SSH,LDAP,andLUNmaskingPlatformssupportedIBMSystemx,IBMPowerSystems,non-IBMx86servers;Windows,Linux,IBMAIX,VIOSoperatingsystemsLimitedwarrantyOne-yearon-sitelimitedwarrantywith9x5nextbusinessdayresponseServiceandsupportOptionalwarrantyserviceupgradesandpost-warrantyservicesareavailable:on-sitewith24x72-hour,24x7or9x5sameday,or9x5nextbusinessdayresponseDimensionsHeight:44mm(1.
7in.
),width:432mm(17.
0in.
),depth:638mm(25.
1in.
)Weight12.
7kg(28lb)*4KBI/Oblocksize.
**256KBI/Oblocksize.
IBMFlashSystem720andIBMFlashSystem8206ModelsTable2liststheFlashSystem720andFlashSystem820models.
Table2.
ModelsDescriptionMachinetype-modelIBMFlashSystem7209831-AS2IBMFlashSystem8209831-AE2TheFlashSystem720andFlashSystem820storagesystemsareshippedwiththefollowingitems:StatementofLimitedWarrantyzQuickstartguidezDocumentationCDcontainingInstallationandUser'sGuidezRailkitzTwoIEC320-C13toC14rackPDUpowercordszTheFlashSystem720andFlashSystem820storagesystemsrequireinterfaceandflashmodulestobeorderedwiththebasemodel.
See"Interfacemodules"and"Flashmodules"sectionsfordetails.
InterfacemodulesFlashSystem720andFlashSystem820supporteither8GbFibreChannel(FC)or40GbpsInfiniBandconnectivitywiththeinterfacemodulesshowninTable3(onlyonefeaturecanbeselected).
Table3.
SupportedinterfacemodulesDescriptionFeaturecodeMaximumquantitysupported8GbFC4PortExtIntAF041IBQDR4PortExtIntAF051Eachinterfacemodulefeaturecodecontainstwodual-portcards(either8GbFibreChannelorQDRInfiniBand)foratotaloffourportsinthesystem.
FCinterfacemodulescomestandardwithfour(onepereachport)8GbFCshortwaveSFP+transceiverswithLCduplexconnector.
InfiniBandinterfacemoduleshaveQSFPreceptacles.
FCinterfacessupportFibreChannelProtocol(FCP)only,withpoint-to-point(FC-P2P),arbitratedloop(FC-AL),andswitchedfabric(FC-SW)topologies.
FCinterfacescanbeconfiguredasN_portorNL_porttypes.
InfiniBandinterfacessupportSCSIRDMAProtocol(SRP)only.
Dual-portinterfacemodulessupportfullactive-activeloadbalancingandfailovermulti-pathing,thoughhostsoftwaresupportforthisfunctioncanvary.
IBMFlashSystem720andIBMFlashSystem8207FlashmodulesFlashSystem720andFlashSystem820provideconfigurablecapacityandoptionalRAID5ProtectionfeaturewiththeflashmoduleslistedinTable4.
Table4.
SupportedflashmodulesDescriptionFeaturecodeMaximumquantitysupportedSLCflashmodulepacks(forFlashSystem720,onlyonepackcanbeordered)6TBSLCRAID0(12-pack)AF02112TBSLCRAID0(12-pack)AF031BaseeMLCflashmodulepacks(forFlashSystem820,onlyonepackcanbeordered)12TBeMLCRAID0(12-pack)AF0E124TBeMLCRAID0(12-pack)AF0F1RAID5protection(optional,pre-selected)RAID5ProtectionAF0K1FlashSystem720flashmodulesuse32nmSLCflashchips,nominallyratedfor100,000program/erase(P/E)cycles,andFlashSystem820flashmodulesuse32nmeMLCflashchips,nominallyratedfor30,000P/Ecycles.
FlashSystem720single-densityflashmodulehasarawcapacityofapproximately680GB,andausablecapacityofapproximately500GBafteroverprovisioningandVariableStripeRAIDoverhead.
FlashSystem720double-densityflashmodulehasarawcapacityofapproximately1.
36TB,andausablecapacityofapproximately1TBafteroverprovisioningandVariableStripeRAIDoverhead.
FlashSystem820single-densityflashmodulehasarawcapacityofapproximately1.
36TB,andausablecapacityofapproximately1TBafteroverprovisioningandVariableStripeRAIDoverhead.
FlashSystem820double-densityflashmodulehasarawcapacityofapproximately2.
72TB,andausablecapacityofapproximately2TBafteroverprovisioningandVariableStripeRAIDoverhead.
Important:Flashmoduletypescannotbemixedwithinasystem.
Thefollowingflashmoduleprotectiontechnologiesaresupported:Module-levelVariableStripeRAIDzErrorcorrectingcodes(ECC)toprovidereconstructionofdatafromflashchipszChecksumsanddataintegrityfieldsprotectingallinternaldatatransferswithinthesystemzOverprovisioningtoenhancewriteenduranceanddecreasewriteamplificationzWearlevelingalgorithmsthatbalancethenumberofwritesamongflashchipsthroughoutthesystemzSweeperalgorithmsthatensurealldatawithinthesystemisreadperiodicallytoavoiddatafadezissuesOptionalRAID5ProtectionfeaturewithhotspareflashmoduletoautomaticallyrebuilddatafromthezfailingorfailedmoduletorestoreafullyredundantstateInaddition,FlashSystem720andFlashSystem820includethreeN+1redundantbatteriesthatareusedtodestagelookuptablesanddatafromRAMbufferstotheflashstorageincaseofpowerfailure.
IBMFlashSystem720andIBMFlashSystem8208Threemodesofoperationaresupportedbythesystems:RAID0zJBOF(justabunchofflash)zRAID5withhotspare(optional)zDefinition:Acombinationofmodule-levelVariableStripeRAIDandRAID5withhotspareacrossflashmodulesiscalledtwo-dimensional(2D)FlashRAID.
InaRAID0mode,dataisstripedacrossallavailableflashmodulesinatraditionalRAID0layout(stripesize4KB).
JBOFmodeallowseachflashmoduletobetreatedseparatelywithoutstripingdataacrossthemodules.
InJBOFmode,eachflashmodulecorrespondstoasinglelogicalvolume.
InaRAID5mode,dataisstripedacross11flashmodules,withrotatingparityprotectionina10+1RAID5layout(stripesize4KB).
Inthismode,onemoduleisreservedasahotspare.
Capacityavailableforuserdataisequivalenttothesumofusablecapacitiesfor10flashmodules.
InaRAID0orRAIDmode,ypto1024logicalvolumes(sometimesreferredtoasLUNs)canbecreatedinthesystem,withaminimumsizeof1GBandamaximumsizeofthefullavailablesystemcapacity.
UnlikeRAID0andJBOFmode,RAID5protectionfeatureprovidescompleteredundancyfortheflashmodulestoavoiddatalossincaseofflashmodulefailure.
WithRAID5featureactivated,FlashSystem720andFlashSystem820offerfullhighavailabilityandprotectionformissioncriticaldata,withoutsinglepointoffailure.
Underthedirectionofthemanagementmodule,thesystemscancoordinatedatatransferbetweenmodules;forexample,torebuildasystem-levelRAID-5datalayoutincaseofaflashmodulefailure,ifRAID5Protectionfeatureisactivated.
Important:InRAID0orJBOFmode,failuresofasingleflashmodulecontainingdatawillmostlikelycompromisesystemdataintegrityforlogicalvolumesstoredonthoseflashmodules.
IfRAID0orJBOFmodeisused,datamustbereplicatedindependentlyofFlashSystem720andFlashSystem820storagesystemsforprotectionagainstcompleteflashmodulefailures.
IBMFlashSystem720andIBMFlashSystem8209NetworkcablesFlashSystem720andFlashSystem820supportnetworkcablesthatarelistedinTable5.
Table5.
SupportedcablesDescriptionFeaturecodeMaximumquantitysupportedFibreChannelcables(supportedonFibreChannelports)1mFiberCable(LC-LC)370045mFiberCable(LC-LC)37014InfiniBandcables(supportedonInfiniBandports)1mIBMQSFPCopIBA0RD43mIBMQSFPCopIBA0RE43mIBMQSFPOptQDRIB5989410mIBMQSFPOptQDRIB599041mMlnxQSFPCopFDR14IBA2YG43mMlnxQSFPCopFDR14IBA2YH43mMlnxQSFPOptFDR14IBA2YL410mMlnxQSFPOptFDR14IBA2YN4Networkmanagementportssupport1000BASE-TconnectivityandrequiresUTPCategory5,5E,or6cablewithRJ-45connector(upto100meters).
IBMFlashSystem720andIBMFlashSystem82010PowercordsFlashSystem720andFlashSystem820comestandardwithtwoIEC320-C13toC14rackPDUpowercords.
Optionally,country-specificlinecordscanbeorderedifneeded.
SeeTable6.
Table6.
SupportedlinecordsDescriptionFeaturecodeorpartnumberMaximumquantitysupportedLinecord-2.
8m(China)62102Linecord-2.
8m(AS/NZ)62112Linecord-2.
8m(Europe)62122Linecord-2.
8m(Denmark)62132Linecord-2.
8m(S.
Africa)62142Linecord-2.
8m(UK)62152Linecord-2.
8m(Swiss)62162Linecord-2.
8m(Ita/Chile)62172Linecord-2.
8m(Israel)62182Linecord-2.
8m(SKorea)62192Linecord-2.
8m(Argentina)62222Linecord-2.
8m(India)62692Linecord-2.
8m(Japan)63142Linecord-2.
8m120V(US)63132Linecord-2.
8m(Taiwan)63862Linecord-2.
8m(Brazil)65322IBMFlashSystem720andIBMFlashSystem82011SystemsmanagementFlashSystem720andFlashSystem820havebuilt-inLCDdisplay(seeFigure5)toperformbasicconfigurationandmonitoringtasks.
Figure5.
LCDdisplayandcontrolsThefollowingtaskscanbeperformedthroughtheLCDdisplay:ConfigureIPaddresseszReboot/shutdownthesystemzMonitorsystemstatuszFlashSystem720andFlashSystem820areshippedwithtwomanagementmoduleswhichrunahighlycustomizedLinux-basedoperatingsystemthatcoordinatesandmonitorsallsignificantfunctionsinthesystem.
EachmanagementmodulehasoneRJ-45GigabitEthernetportforremotemanagement.
Managementmodulesareconfiguredinanactive/passiveredundantpair.
Thefollowingremotemanagementmethodsaresupported:Java-basedgraphicaluserinterface(GUI)throughwebbrowserzCommand-lineinterface(CLI)throughTelnetandSecureShell(SSH)zSimplenetworkmanagementprotocol(SNMP)zThefollowingtaskscanbeperformedwiththemanagementmodule:DefiningtheuseraccountsandpasswordszConfiguringemailnotificationszMonitoringthestatusofthesystem:zEventlogzFanszTemperatureszPowerzManagingotherFlashSystemunitsinthenetworkfromthesinglewebconsolezIBMFlashSystem720andIBMFlashSystem82012ControllingtheFlashSystemunit:zPoweringon/offzUptadingfirmwarezConfiguringnetworksettingszChangingstoragemode(JBOForRAID0)zCreatinglogicalvolumes(LUNs)zConfiguringLUNmaskingzConfiguringhostinterfaceszConfiguringusersecurityzSettingthedateandtimezSupportedplatformsIBMFlashSystemsystemssupportawiderangeofoperatingsystems(WindowsServer2003and2008,Linux,andIBMAIX),hardwareplatforms(IBMSystemx,IBMPowerSystems,andx86serversnotfromIBM),HBAs,andSANfabrics.
Forspecificinformation,seetheSystemStorageInteroperationCenter(SSIC):http://ibm.
com/systems/support/storage/ssicPhysicalandelectricalspecificationsFlashSystem720andFlashSystem820havethefollowingphysical,electrical,andenvironmentalspecifications:Dimensionsandweight(approximate):zHeight:44mm(1.
7in.
)zWidth:432mm(17.
0in)zDepth:638mm(25.
1in)zWeight:12.
7kg(28lb)zOperatingenvironment:zTemperature:zOperating:10-35degreesC(50-95degreesF)at30.
5mbelowto3000mabovesealevelz(100ftbelowto9,840ftabovesealevel)Non-operating:-10-50degreesC(14-125degreesF)zHumidity:zOperating:20%-80%zNon-operating:10%-90%zSupportedelectricalinput:z100-240(nominal)Vac;50-60HzzInputelectricalpower(approximately):zFlashSystem720:350wattszFlashSystem820:300wattszBTUoutput:zFlashSystem720:1194BTU/hrzFlashSystem820:1023BTU/hrzAcoustical:zNoiseemission:8.
0belszIBMFlashSystem720andIBMFlashSystem82013WarrantyoptionsFlashSystem720andFlashSystem820havea1-yearon-sitewarrantywith9x5nextbusinessdayterms.
IBMoffersoptionalwarrantyandmaintenanceserviceupgradesforthesesystems:Warrantyserviceupgradesz24x7on-siterepairwith2-hourtargetresponsetimez24x7on-siterepairwithsamedaytargetresponsetimez9x5on-siterepairwithsamedaytargetresponsetimezMaintenance(post-warranty)serviceofferingsz24x7on-siterepairwith2-hourtargetresponsetimez24x7on-siterepairwithsamedaytargetresponsetimez9x5on-siterepairwithsamedaytargetresponsetimez9x5on-siterepairwithnextbusinessdaytargetresponsetimezTable7explainsthewarrantyserviceleveldefinitionsinmoredetail.
Table7.
WarrantyserviceleveldefinitionsTermDescriptionOn-siteserviceAservicetechniciancomestothemachine'slocationforequipmentrepair.
24x72-hourAservicetechnicianisscheduledtoarriveatmachine'slocationwithintwohoursafterremoteproblemdeterminationiscomplete,ifIBMdetermineson-siteserviceisrequired.
IBMprovides24-hourservice,everyday,includingIBMholidays.
24x7samedayAservicetechnicianisscheduledtoarriveatmachine'slocationwithinfourhoursafterremoteproblemdeterminationiscomplete,ifIBMdetermineson-siteserviceisrequired.
IBMprovides24-hourservice,everyday,includingIBMholidays.
9x5samedayAservicetechnicianisscheduledtoarriveatmachine'slocationwithinfourbusinesshoursafterremoteproblemdeterminationiscomplete,ifIBMdetermineson-siteserviceisrequired.
IBMprovidesservicefrom8:00a.
m.
to5:00p.
m.
intheclient'slocaltimezone,MondaythroughFriday,excludingIBMholidays.
Ifitisafter1:00p.
m.
,anditisdeterminedthaton-siteserviceisrequired,theclientcanexpecttheservicetechniciantoarrivethemorningofthefollowingbusinessday.
Fornoncriticalservicerequests,aservicetechnicianwillarrivebytheendofthefollowingbusinessday.
9x5nextbusinessdayAservicetechnicianisscheduledtoarriveatmachine'slocationonthebusinessdayafterwereceiveyourcall,followingremoteproblemdetermination,ifIBMdetermineson-siteserviceisrequired.
IBMprovidesservicefrom8:00a.
m.
to5:00p.
m.
intheclient'slocaltimezone,MondaythroughFriday,excludingIBMholidays.
RegulatorycomplianceFlashSystem720andFlashSystem820conformtothefollowingstandards:FCC-VerifiedtocomplywithPart15oftheFCCRules,ClassAzCanadaICES-003,issue4,ClassAzIEC/EN60950-1zCBCertificatezUL60950-1CAN/CSAC22.
2No.
60950-1zCEMarkzEN55022/CISPR22,ClassAzIBMFlashSystem720andIBMFlashSystem82014FibreChannelswitchesThesystemscanbeconnectedtoIBMSystemNetworkingFibreChannelswitchesthatarelistedTable8.
Important:Allpossibleconfigurationsmightnotbesupported.
End-to-endconfigurationsupportmustbeverifiedthroughtheSSICwebsite:http://ibm.
com/systems/support/storage/ssicTable8.
IBMSystemNetworking-FibreChannelswitchesMachinetype-modelDescriptionIBMSystemNetworking-EntrySANswitches2498-F24IBMSystemStorageSAN24B-5(upto2416GbFCports)2498-B24IBMSystemStorageSAN24B-4Express(upto248GbFCports)2053-424CiscoMDS9124ExpressforIBMSystemStorage(upto244GbFCports)IBMSystemNetworking-MidrangeSANswitches2498-F48IBMSystemStorageSAN48B-5(upto4816GbFCports)2498-B80IBMSystemStorageSAN80B-4(upto808GbFCports)2498-B40IBMSystemStorageSAN40B-4(upto408GbFCports)2417-C48CiscoMDS9148forIBMSystemStorage(upto488GbFCports)IBMSystemNetworking-EnterpriseSANdirectors2499-816IBMSystemStorageSAN768B-2(upto38416GbFCports)2499-416IBMSystemStorageSAN384B-2(upto19216GbFCports)2499-384IBMSystemStorageSAN768B(upto5128GbFCports)2499-192IBMSystemStorageSAN384B(upto2568GbFCports)2054-E11CiscoMDS9513forIBMSystemStorage(upto5248GbFCports)2054-E07CiscoMDS9509forIBMSystemStorage(upto3368GbFCports)2054-E04CiscoMDS9506forIBMSystemStorage(upto1928GbFCports)IBMFlashSystem720andIBMFlashSystem82015UninterruptiblepowersupplyunitsThesystemssupportattachmenttotheuninterruptiblepowersupply(UPS)unitslistedinTable9.
Table9.
UninterruptiblepowersupplyunitsPartnumberDescriptionRack-mountedUPS21303RXIBMUPS7500XHV21304RXIBMUPS10000XHV24195KXIBMUPS500053951AXIBM1500VALCD2URackUPS(100V/120V)53951KXIBM1500VALCD2URackUPS(230V)53952AXIBM2200VALCD2URackUPS(100V/120V)53952KXIBM2200VALCD2URackUPS(230V)53953AXIBM3000VALCD3URackUPS(100V/120V)53953JXIBM3000VALCD3URackUPS(200V/208V)53956AXIBM6000VALCD4URackUPS(200V/208V)53956KXIBM6000VALCD4URackUPS(230V)53959KXIBM11000VALCD5URackUPS(200V/208V/230V)Formoreinformation,seethefollowingIBMRedbooksProductGuides:IBM3000VALCD3URackUninterruptiblePowerSupplyzhttp://www.
redbooks.
ibm.
com/abstracts/tips0782.
htmlOpenIBM6000VALCD4URackUPSzhttp://www.
redbooks.
ibm.
com/abstracts/tips0793.
htmlOpenIBMFlashSystem720andIBMFlashSystem82016PowerdistributionunitsThesystemssupportattachmentstothepowerdistributionunits(PDUs)listedinTable10.
Table10.
Powerdistributionunits(part1)PartnumberDescriptionSwitchedandMonitoredPDUs46M4002IBM1U9C19/3C13ActiveEnergyManagerDPIPDU46M4003IBM1U9C19/3C13ActiveEnergyManager60A3PhasePDU46M4004IBM1U12C13ActiveEnergyManagerDPIPDU46M4005IBM1U12C13ActiveEnergyManager60A3PhasePDU46M4167IBM1U9C19/3C13SwitchedandMonitored30A3PhasePDU46M4116IBM0U24C13SwitchedandMonitored30APDU46M4119IBM0U24C13SwitchedandMonitored32APDU46M4134IBM0U12C19/12C13SwitchedandMonitored50A3PhasePDU46M4137IBM0U12C19/12C13SwitchedandMonitored32A3PhasePDUEnterprisePDUs71762MXIBMUltraDensityEnterprisePDUC19PDU+(WW)71762NXIBMUltraDensityEnterprisePDUC19PDU(WW)71763MUIBMUltraDensityEnterprisePDUC193Phase60APDU+(NA)71763NUIBMUltraDensityEnterprisePDUC193Phase60APDU(NA)39M2816IBMDPIC13EnterprisePDUwithoutlinecord39Y8923DPI60AThreePhaseC19EnterprisePDUwithIEC3093P+G(208V)fixedlinecord39Y8941DPISinglePhaseC13EnterprisePDUwithoutlinecord39Y8948DPISinglePhaseC19EnterprisePDUwithoutlinecordFront-endPDUs39Y8934DPI32amp/250VFront-endPDUwithIEC3092P+Gndconnector39Y8935DPI63amp/250VFront-endPDUwithIEC3092P+Gndconnector39Y893830amp/125VFront-endPDUwithNEMAL5-30Pconnector39Y893930amp/250VFront-endPDUwithNEMAL6-30Pconnector39Y894060amp/250VFront-endPDUwithIEC30960A2P+N+GndconnectorIBMFlashSystem720andIBMFlashSystem82017Table10.
Powerdistributionunits(part2)PartnumberDescriptionUniversalPDUs39Y8951DPIUniversalRackPDUwithUSLVandHVlinecords39Y8952DPIUniversalRackPDUwithCEE7-VIIEuropeLC39Y8953DPIUniversalRackPDUwithDenmarkLC39Y8954DPIUniversalRackPDUwithIsraelLC39Y8955DPIUniversalRackPDUwithItalyLC39Y8956DPIUniversalRackPDUwithSouthAfricaLC39Y8957DPIUniversalRackPDUwithUKLC39Y8958DPIUniversalRackPDUwithAS/NZLC39Y8959DPIUniversalRackPDUwithChinaLC39Y8962DPIUniversalRackPDU(Argentina)39Y8960DPIUniversalRackPDU(Brazil)39Y8961DPIUniversalRackPDU(India)0UBasicPDUs46M4122IBM0U24C1316A3PhasePDU46M4125IBM0U24C1330A3PhasePDU46M4128IBM0U24C1330APDU46M4131IBM0U24C1332APDU46M4140IBM0U12C19/12C1360A3PhasePDU46M4143IBM0U12C19/12C1332A3PhasePDUFormoreinformation,seethelistofIBMRedbooksProductGuidesinthePowerinfrastructurecategory:http://www.
redbooks.
ibm.
com/portals/systemxOpen&page=pg&cat=powerIBMFlashSystem720andIBMFlashSystem82018RackcabinetsThesystemssupporttherackcabinetslistedinTable11.
Table11.
RackcabinetsPartnumberDescription93072PXIBM25UStaticS2StandardRack93072RXIBM25UStandardRack93074RXIBM42UStandardRack93074XXIBM42UStandardRackExtension93084EXIBM42UEnterpriseExpansionRack93084PXIBM42UEnterpriseRack93604EXIBM42U1200mmDeepDynamicExpansionRack93604PXIBM42U1200mmDeepDynamicRack93614EXIBM42U1200mmDeepStaticExpansionRack93614PXIBM42U1200mmDeepStaticRack93624EXIBM47U1200mmDeepStaticExpansionRack93624PXIBM47U1200mmDeepStaticRack93634CXIBMPureFlexSystem42URack93634DXIBMPureFlexSystem42UExpansionRack93634EXIBM42U1100mmDynamicExpansionRack93634PXIBM42U1100mmDynamicRack99564RXIBMS242UDynamicStandardRack99564XXIBMS242UDynamicStandardExpansionRackFormoreinformation,seethelistofIBMRedbooksProductGuidesintheRackcabinetsandoptionscategory:http://www.
redbooks.
ibm.
com/portals/systemxOpen&page=pg&cat=rackIBMFlashSystem720andIBMFlashSystem82019IBMGlobalFinancingIBMGlobalFinancingcanhelpyouobtaintheITsolutionyouneedwhilepreservingfundingforotherstrategicinvestmentsandoptimizingcashflow.
OurFairMarketValue(FMV)leasehelpsensurethatyouhavethelatestIBMtechnology,andwithourmid-leaseupgradecapability,youcanincreasethecapacityofthesystemwithlittletonochangeinmonthlypayments.
Attheendofthelease,takeadvantageofourflexibleend-of-leaseoptionstofityourchangingbusinessneeds.
IBMGlobalFinancinghasthebreadthanddepthofofferings,longevity,provensuccess,andglobalreachtohelpyoudeveloparobustfinancingandassetmanagementstrategythatprovidesyoutheopportunitytousenewtechnologiesandturnyourambitiousvisionintoatangiblesolution.
HerearesomeotherreasonswhyworkingwithIBMmakessolidfinancialsense:Expandyourpurchasingpower:Affordablemonthlypaymentsallowyoutochangethetechnologyzacquisitiondiscussionfrom"whatcanIaffordnow"to"whatsolutionisreallyrightformybusiness.
"IBMGlobalFinancingallowsyoutoexpandyourpurchasingpowertogetyoutherightsolution.
Accelerateyourproject'scashflowbreak-evenpoint:AcquireyourIBMtechnologytodayandbegintozrealizeitsbenefitsnow.
AnFMVleasecanhelpyougetthesolutionyouneednow,withlowmonthlypaymentsthatbetteralignup-frontcostswiththeanticipatedreturnoninvestment(ROI)fromthetechnology.
Easytoacquirewithaffordablerates:Weofferone-stopshoppingforatotalITsolution,soyoucanzacquireIBMhardware,software,servicesandthefinancingyouneedfromoneITprovider.
Plus,weprovidesimple,easy-to-understandcontractsandquickapprovals.
Astheworld'slargestITfinancingprovider,withanassetbaseofUS$35.
8billionandover125,000customers,IBMGlobalFinancingoffershighlycompetitiveratesthatpromotelowtotalcostofownership(TCO)andlowmonthlypayments.
IBMGlobalFinancingoperatesinmorethan50countries.
Gotohttp://ibm.
com/financingforfinancingoptionsinyourcountryandtocontactalocalfinancingspecialist.
IBMGlobalFinancingofferingsareprovidedthroughIBMCreditLLCintheUnitedStatesandotherIBMsubsidiariesanddivisionsworldwidetoqualifiedcommercialandgovernmentclients.
Ratesandavailabilitysubjecttoclient'screditrating,financingterms,offeringtype,equipmentandproducttypeandoptions,andmightvarybycountry.
Non-hardwareitemsmustbeone-time,nonrecurringchargesandarefinancedbymeansofloans.
Otherrestrictionsmightapply.
Ratesandofferingsaresubjecttochange,extensionorwithdrawalwithoutnoticeandmightnotbeavailableinallcountries.
ContactyourlocalIBMGlobalFinancingrepresentativeforadditionaldetail.
IBMFlashSystem720andIBMFlashSystem82020RelatedpublicationsandlinksFormoreinformation,seetheseresources:USAnnouncementLetter-IBMFlashSystem720andIBMFlashSystem820zhttp://ibm.
com/common/ssi/cgi-bin/ssialiasinfotype=dd&subtype=ca&&htmlfid=897/ENUS113-047IBMFlashSystemfamilyproductpagezhttp://www.
ibm.
com/storage/flashIBMRedbooksSolutionGuidesforIBMFlashSystemfamily:zhttp://www.
redbooks.
ibm.
com/redbooks.
nsf/searchsiteSearchView&query=flashssIBMSupportPortalzhttp://ibm.
com/support/entry/portal/IBMSystemStorageInteroperationCenter(SSIC)zhttp://www.
ibm.
com/systems/support/storage/ssicIBMFlashSystem720andIBMFlashSystem82021NoticesThisinformationwasdevelopedforproductsandservicesofferedintheU.
S.
A.
IBMmaynotoffertheproducts,services,orfeaturesdiscussedinthisdocumentinothercountries.
ConsultyourlocalIBMrepresentativeforinformationontheproductsandservicescurrentlyavailableinyourarea.
AnyreferencetoanIBMproduct,program,orserviceisnotintendedtostateorimplythatonlythatIBMproduct,program,orservicemaybeused.
Anyfunctionallyequivalentproduct,program,orservicethatdoesnotinfringeanyIBMintellectualpropertyrightmaybeusedinstead.
However,itistheuser'sresponsibilitytoevaluateandverifytheoperationofanynon-IBMproduct,program,orservice.
IBMmayhavepatentsorpendingpatentapplicationscoveringsubjectmatterdescribedinthisdocument.
Thefurnishingofthisdocumentdoesnotgiveyouanylicensetothesepatents.
Youcansendlicenseinquiries,inwriting,to:IBMDirectorofLicensing,IBMCorporation,NorthCastleDrive,Armonk,NY10504-1785U.
S.
A.
ThefollowingparagraphdoesnotapplytotheUnitedKingdomoranyothercountrywheresuchprovisionsareinconsistentwithlocallaw:INTERNATIONALBUSINESSMACHINESCORPORATIONPROVIDESTHISPUBLICATION"ASIS"WITHOUTWARRANTYOFANYKIND,EITHEREXPRESSORIMPLIED,INCLUDING,BUTNOTLIMITEDTO,THEIMPLIEDWARRANTIESOFNON-INFRINGEMENT,MERCHANTABILITYORFITNESSFORAPARTICULARPURPOSE.
Somestatesdonotallowdisclaimerofexpressorimpliedwarrantiesincertaintransactions,therefore,thisstatementmaynotapplytoyou.
Thisinformationcouldincludetechnicalinaccuraciesortypographicalerrors.
Changesareperiodicallymadetotheinformationherein;thesechangeswillbeincorporatedinneweditionsofthepublication.
IBMmaymakeimprovementsand/orchangesintheproduct(s)and/ortheprogram(s)describedinthispublicationatanytimewithoutnotice.
Anyreferencesinthisinformationtonon-IBMWebsitesareprovidedforconvenienceonlyanddonotinanymannerserveasanendorsementofthoseWebsites.
ThematerialsatthoseWebsitesarenotpartofthematerialsforthisIBMproductanduseofthoseWebsitesisatyourownrisk.
IBMmayuseordistributeanyoftheinformationyousupplyinanywayitbelievesappropriatewithoutincurringanyobligationtoyou.
Informationconcerningnon-IBMproductswasobtainedfromthesuppliersofthoseproducts,theirpublishedannouncementsorotherpubliclyavailablesources.
IBMhasnottestedthoseproductsandcannotconfirmtheaccuracyofperformance,compatibilityoranyotherclaimsrelatedtonon-IBMproducts.
Questionsonthecapabilitiesofnon-IBMproductsshouldbeaddressedtothesuppliersofthoseproducts.
Thisinformationcontainsexamplesofdataandreportsusedindailybusinessoperations.
Toillustratethemascompletelyaspossible,theexamplesincludethenamesofindividuals,companies,brands,andproducts.
Allofthesenamesarefictitiousandanysimilaritytothenamesandaddressesusedbyanactualbusinessenterpriseisentirelycoincidental.
Anyperformancedatacontainedhereinwasdeterminedinacontrolledenvironment.
Therefore,theresultsobtainedinotheroperatingenvironmentsmayvarysignificantly.
Somemeasurementsmayhavebeenmadeondevelopment-levelsystemsandthereisnoguaranteethatthesemeasurementswillbethesameongenerallyavailablesystems.
Furthermore,somemeasurementmayhavebeenestimatedthroughextrapolation.
Actualresultsmayvary.
Usersofthisdocumentshouldverifytheapplicabledatafortheirspecificenvironment.
COPYRIGHTLICENSE:Thisinformationcontainssampleapplicationprogramsinsourcelanguage,whichillustrateprogrammingtechniquesonvariousoperatingplatforms.
Youmaycopy,modify,anddistributethesesampleprogramsinanyformwithoutpaymenttoIBM,forthepurposesofdeveloping,using,marketingordistributingapplicationprogramsconformingtotheapplicationprogramminginterfacefortheoperatingplatformforwhichthesampleprogramsarewritten.
Theseexampleshavenotbeenthoroughlytestedunderallconditions.
IBM,therefore,cannotguaranteeorimplyreliability,serviceability,orfunctionoftheseprograms.
CopyrightInternationalBusinessMachinesCorporation2013.
Allrightsreserved.
NotetoU.
S.
GovernmentUsersRestrictedRights--Use,duplicationordisclosurerestrictedbyGSAADPScheduleContractwithIBMCorp.
IBMFlashSystem720andIBMFlashSystem82022ThisdocumentwascreatedorupdatedonOctober13,2014.
Sendusyourcommentsinoneofthefollowingways:UsetheonlineContactusreviewformfoundat:zibm.
com/redbooksSendyourcommentsinane-mailto:zredbooks@us.
ibm.
comMailyourcommentsto:zIBMCorporation,InternationalTechnicalSupportOrganizationDept.
HYTDMailStationP0992455SouthRoadPoughkeepsie,NY12601-5400U.
S.
A.
Thisdocumentisavailableonlineathttp://www.
ibm.
com/redbooks/abstracts/tips1003.
html.
TrademarksIBM,theIBMlogo,andibm.
comaretrademarksorregisteredtrademarksofInternationalBusinessMachinesCorporationintheUnitedStates,othercountries,orboth.
TheseandotherIBMtrademarkedtermsaremarkedontheirfirstoccurrenceinthisinformationwiththeappropriatesymbol(or),indicatingUSregisteredorcommonlawtrademarksownedbyIBMatthetimethisinformationwaspublished.
Suchtrademarksmayalsoberegisteredorcommonlawtrademarksinothercountries.
AcurrentlistofIBMtrademarksisavailableontheWebathttp://www.
ibm.
com/legal/copytrade.
shtmlThefollowingtermsaretrademarksoftheInternationalBusinessMachinesCorporationintheUnitedStates,othercountries,orboth:AIXCalibratedVectoredCoolingEasyTierFlashSystemIBMIBMFlashSystemPowerSystemsPureFlexRedbooksRedbooks(logo)StorwizeSystemStorageSystemxThefollowingtermsaretrademarksofothercompanies:LinuxisatrademarkofLinusTorvaldsintheUnitedStates,othercountries,orboth.
Windows,andtheWindowslogoaretrademarksofMicrosoftCorporationintheUnitedStates,othercountries,orboth.
Othercompany,product,orservicenamesmaybetrademarksorservicemarksofothers.

香港CN2云服务器 1核 2G 35元/月 妮妮云

妮妮云的来历妮妮云是 789 陈总 张总 三方共同投资建立的网站 本着“良心 便宜 稳定”的初衷 为小白用户避免被坑妮妮云的市场定位妮妮云主要代理市场稳定速度的云服务器产品,避免新手购买云服务器的时候众多商家不知道如何选择,妮妮云就帮你选择好了产品,无需承担购买风险,不用担心出现被跑路 被诈骗的情况。妮妮云的售后保证妮妮云退款 通过于合作商的友好协商,云服务器提供2天内全额退款到网站余额,超过2天...

PhotonVPS:美国Linux VPS半价促销2.5美元/月起,可选美国洛杉矶/达拉斯/芝加哥/阿什本等四机房

photonvps怎么样?photonvps现在针对旗下美国vps推出半价促销优惠活动,2.5美元/月起,免费10Gbps DDoS防御,Linux系统,机房可选美国洛杉矶、达拉斯、芝加哥、阿什本。以前觉得老牌商家PhotonVPS贵的朋友可以先入手一个月PhotonVPS美国Linux VPS试试了。PhotonVPS允许合法大人内容,支持支付宝、paypal和信用卡,30天退款保证。Photo...

香港ceranetworks(69元/月) 2核2G 50G硬盘 20M 50M 100M 不限流量

香港ceranetworks提速啦是成立于2012年的十分老牌的一个商家这次给大家评测的是 香港ceranetworks 8核16G 100M 这款产品 提速啦老板真的是豪气每次都给高配我测试 不像别的商家每次就给1核1G,废话不多说开始跑脚本。香港ceranetworks 2核2G 50G硬盘20M 69元/月30M 99元/月50M 219元/月100M 519元/月香港ceranetwork...

systemx为你推荐
酒店回应名媛拼单泰国酒店写错入住人姓名有影响吗?怎么查询商标想要知道一个商标是否被注册,在哪里查到的比较权威?mathplayerjavascript 如何判断document.body.innerHTML是否为空bbs.99nets.com做一款即时通讯软件难吗 像hi qq这类的陈嘉垣大家觉得陈嘉桓漂亮还是钟嘉欣漂亮?8090lu.com8090lu.com怎么样了?工程有进展吗?www.55125.cn如何登录www.jbjy.cnm.2828dy.combabady为啥打不开了,大家帮我提供几个看电影的网址javbibi日文里的bibi是什么意思www.toutoulu.com老板强大的外包装还是被快递弄断了
香港服务器99idc z.com 网站挂马检测工具 湖南服务器托管 空间出租 北京双线机房 域名接入 cn3 中国电信测速网 优酷黄金会员账号共享 宏讯 国内域名 睿云 forwarder 认证机构 weblogic部署 香港打折信息 卡巴斯基免费版 万根云主机 电脑主机嗡嗡响 更多