i目录1设备管理·1-11.
1设备管理配置命令·1-11.
1.
1clockdatetime·1-11.
1.
2clockprotocol·1-21.
1.
3clocksummer-time·1-21.
1.
4clocktimezone1-41.
1.
5command·1-51.
1.
6copyright-infoenable1-61.
1.
7displayalarm1-71.
1.
8displayasset-info·1-81.
1.
9displayclock·1-91.
1.
10displaycopyright·1-101.
1.
11displaycpu-usage1-111.
1.
12displaycpu-usageconfiguration1-121.
1.
13displaycpu-usagehistory1-131.
1.
14displaydevice1-151.
1.
15displaydevicemanuinfo1-161.
1.
16displaydevicemanuinfochassis-only1-171.
1.
17displaydevicemanuinfopower1-171.
1.
18displaydiagnostic-information·1-181.
1.
19displayenvironment·1-201.
1.
20displayfan·1-211.
1.
21displayhardware-failure-detection1-231.
1.
22displayhardware-failure-protection1-241.
1.
23displaymemory1-251.
1.
24displaymemory-threshold1-271.
1.
25displaypower-supply1-291.
1.
26displayschedulerjob1-311.
1.
27displayschedulerlogfile1-311.
1.
28displayschedulerreboot·1-321.
1.
29displayschedulerschedule1-331.
1.
30displayswitch-modestatus1-341.
1.
31displaysystemstablestate1-37ii1.
1.
32displaysystem-working-mode·1-391.
1.
33displaytransceiveralarm1-391.
1.
34displaytransceiverdiagnosis1-411.
1.
35displaytransceiverinterface1-421.
1.
36displaytransceivermanuinfo1-431.
1.
37displayversion1-441.
1.
38displayversion-update-record·1-441.
1.
39displayxbar1-451.
1.
40fabricload-sharingmode1-461.
1.
41fabric-mode1-471.
1.
42forward-path-detectionenable·1-481.
1.
43hardware-failure-detection1-491.
1.
44hardware-failure-protectionaggregation·1-491.
1.
45hardware-failure-protectionauto-down·1-501.
1.
46header·1-511.
1.
47job1-521.
1.
48memory-threshold1-531.
1.
49memory-thresholdusage1-541.
1.
50monitorcpu-usageenable·1-551.
1.
51monitorcpu-usageinterval1-561.
1.
52monitorcpu-usagethreshold1-571.
1.
53monitorhandshake-timeoutdisable-port·1-581.
1.
54password-recoveryenable1-591.
1.
55reboot·1-601.
1.
56resetasset-info·1-611.
1.
57resetschedulerlogfile1-621.
1.
58resetversion-update-record1-631.
1.
59restorefactory-default1-631.
1.
60schedulerjob1-641.
1.
61schedulerlogfilesize1-651.
1.
62schedulerrebootat·1-651.
1.
63schedulerrebootdelay·1-661.
1.
64schedulerschedule1-671.
1.
65setasset-info1-681.
1.
66shutdown-interval·1-691.
1.
67switch-mode1-70iii1.
1.
68sysname1-721.
1.
69system-working-mode·1-731.
1.
70temperature-limit·1-741.
1.
71timeat1-751.
1.
72timeonce1-761.
1.
73timerepeating1-771.
1.
74transceiverphony-alarm-disable·1-791.
1.
75user-role1-791.
1.
76xbar1-801-11设备管理1.
1设备管理配置命令1.
1.
1clockdatetimeclockdatetime命令用来配置设备的系统时间.
【命令】clockdatetimetimedate【缺省情况】设备的UTC时间为出厂时间.
【视图】用户视图【缺省用户角色】network-adminmdc-admin【参数】time:配置的时间,格式为HH:MM:SS(小时:分钟:秒),HH取值范围为0~23,MM和SS取值范围为0~59.
如果要配置成整分,则可以不输入秒;如果要配置成整点,则可以不输入分和秒.
比如将time参数配置为0表示零点.
date:配置的日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日),MM的取值范围为1~12,DD的取值范围与月份有关,YYYY的取值范围为2000~2035.
【使用指导】为了保证与其它设备协调工作,为了更好的监控和维护设备,请确保设备的系统时间是准确的.
请先配置clockprotocolnone命令,再执行本命令.
clockdatetime命令中指定的时间会立即生效,作为当前的系统时间.
后续,设备使用内部晶体震荡器产生的时钟信号计时.
【举例】#配置设备的系统时间为2015年1月1日8时8分8秒.
clockdatetime8:8:81/1/2015#配置设备的系统时间为2015年1月1日8时10分.
clockdatetime8:102015/1/1【相关命令】clockprotocolclocksummer-timeclocktimezonedisplayclock1-21.
1.
2clockprotocolclockprotocol命令用来配置系统时间的获取方式.
undoclockprotocol命令用来恢复缺省情况.
【命令】clockprotocol{none|ntpmdcmdc-id}undoclockprotocol【缺省情况】从缺省MDC通过NTP协议获取时间.
【视图】系统视图【缺省用户角色】network-adminmdc-admin【参数】none:表示通过命令行配置系统时间.
ntp:表示通过NTP(NetworkTimeProtocol,网络时间协议)协议获取时间.
关于NTP的详细介绍和配置,请参见"网络管理和监控配置指导"中的"NTP".
mdcmdc-id:表示时钟的来源MDC编号,取值范围为1~5.
【使用指导】为了保证与其它设备协调工作,为了更好的监控和维护设备,请确保设备的系统时间是准确的.
系统时间的获取方式有:配置clockprotocolnone命令后,通过clockdatetime命令直接配置.
clockdatetime命令中指定的时间即为当前的系统时间.
后续,设备使用内部晶体震荡器产生的时钟信号计时.
配置clockprotocolntp命令后,通过NTP协议从网络中获取时间.
该方式下,设备会周期性的同步服务器的UTC(CoordinatedUniversalTime,国际协调时间)时间,并用同步得到的UTC时间和设备上配置的本地时区、夏令时参数运算,得出当前的系统时间.
该方式获取的时间比命令行配置的时间更精准,推荐使用.
多次执行本命令,最后一次执行的命令生效.
所有MDC的系统时间相同.
当设备从某个MDC获取时钟后,会同步给其它MDC.
【举例】#配置获取UTC时间的方式为通过命令行配置.
system-view[Sysname]clockprotocolnone1.
1.
3clocksummer-timeclocksummer-time命令用来配置夏令时.
1-3undoclocksummer-time命令用来恢复缺省情况.
【命令】clocksummer-timenamestart-timestart-dateend-timeend-dateadd-timeundoclocksummer-time【缺省情况】未配置夏令时.
【视图】系统视图【缺省用户角色】network-adminmdc-admin【参数】name:夏令时的名称,为1~32个字符的字符串,区分大小写.
start-time:开始时间,格式为HH:MM:SS,HH取值范围为0~23,MM和SS取值范围为0~59.
如果要配置成整分,则可以不输入秒;如果要配置成整点,则可以不输入分和秒.
start-date:开始日期,有两种输入方式:直接一次性输入月和日,参数格式为MM/DD,MM取值范围为1~12,DD的取值范围与月份有关.
分次输入月、日,各参数之间以键隔开.
首先输入开始的月份,取值如下:January、February、March、April、May、June、July、August、September、October、November或December;然后输入开始的星期,用当月的第几个星期表示,取值如下:first、second、third、fourth、fifth或last;最后输入起始日,取值为Sunday、Monday、Tuesday、Wednesday、Thursday、Friday或Saturday.
end-time:结束时间,格式为HH:MM:SS,HH取值范围为0~23,MM和SS取值范围为0~59.
如果要配置成整分,则可以不输入秒;如果要配置成整点,则可以不输入分和秒.
end-date:结束日期,有两种输入方式:直接一次性输入月日,参数格式为MM/DD,MM取值范围为1~12,DD的取值范围与月份有关.
分次输入月、日,各参数之间以键隔开.
首先输入开始的月份,取值如下:January、February、March、April、May、June、July、August、September、October、November或December;然后输入开始的星期,用当月的第几个星期表示,取值如下:first、second、third、fourth、fifth或last;最后输入起始日,取值为Sunday、Monday、Tuesday、Wednesday、Thursday、Friday或Saturday.
add-time:偏移时间,格式为HH:MM:SS,HH取值范围为0~23,MM和SS取值范围为0~59.
如果要配置成整分,则可以不输入秒;如果要配置成整点,则可以不输入分和秒.
【使用指导】为了保证与其它设备协调工作,为了更好的监控和维护设备,请确保设备的系统时间是准确的.
1-4配置该命令后,设备会自动重新计算当前的系统时间,计算后得到的系统时间可通过displayclock命令查看.
请将所有网络设备的夏令时和当地夏令时保持一致.
【举例】#配置夏令时PDT,从每年的8月1日的06:00:00开始,到9月1日的06:00:00结束,比当前设备标准时间增加1小时.
system-view[Sysname]clocksummer-timePDT608/01609/011【相关命令】clockdatetimeclocktimezonedisplayclock1.
1.
4clocktimezoneclocktimezone命令用来配置系统所在的时区.
undoclocktimezone命令用来恢复缺省情况.
【命令】clocktimezonezone-name{add|minus}zone-offsetundoclocktimezone【缺省情况】系统所在的时区为零时区,即设备采用UTC时间.
【视图】系统视图【缺省用户角色】network-adminmdc-admin【参数】zone-name:时区名称,为1~32个字符的字符串,区分大小写.
add:在UTC时间的基础上增加指定时间.
minus:在UTC时间的基础上减少指定时间.
zone-offset:与UTC的时间差,格式为HH:MM:SS,HH取值范围为0~23,MM和SS取值范围为0~59,如果要配置成整分,则可以不输入秒;如果要配置成整点,则可以不输入分和秒.
【使用指导】为了保证与其它设备协调工作,为了更好的监控和维护设备,请确保设备的系统时间是准确的.
设配置该命令后,设备会自动重新计算当前的系统时间,计算后得到的系统时间可通过displayclock命令查看.
请将所有网络设备的时区和当地地理时区保持一致.
1-5【举例】#配置本地时区名称为Z5,比UTC标准时间增加5小时.
system-view[Sysname]clocktimezoneZ5add5【相关命令】clockdatetimeclocksummer-timedisplayclock1.
1.
5commandcommand命令用来为Job分配命令.
undocommand命令用来取消为Job分配的命令.
【命令】commandidcommandundocommandid【缺省情况】没有为Job分配命令.
【视图】Job视图【缺省用户角色】network-adminmdc-admin【参数】id:命令编号,取值范围为0~4294967295.
该编号表示命令在Job中的执行顺序,编号小的命令优先执行.
command:为Job分配的命令.
【使用指导】多次输入command命令可以为当前Job分配多条命令,不同命令用编号来唯一区别.
如果新分配命令的编号和已分配的某命令的编号相同,则新分配的命令会覆盖已分配的命令.
通过command分配的命令行必须是设备上可成功执行的命令行,不包括telnet、ftp、ssh2和monitorprocess.
由用户保证配置的正确性,否则,命令行不能自动被执行.
如果需要分配的命令(假设为A)是用户视图下的命令,则直接使用command命令分配即可;如果需要分配的命令(假设为A)是非用户视图下的命令,则必须先分配进入A所在视图的命令(指定较小的id值),再分配A.
定时执行任务时,设备不会与用户交互信息.
当需要用户交互确认时,系统将自动输入"Y"或"Yes";当需要用户交互输入字符信息时,系统将自动输入缺省字符串,没有缺省字符串的将自动输入空字符串.
1-6【举例】#为名称为backupconfig的Job分配命令,以便将配置文件startup.
cfg备份到TFTP服务器192.
168.
100.
11.
system-view[Sysname]schedulerjobbackupconfig[Sysname-job-backupconfig]command2tftp192.
168.
100.
11putflash:/startup.
cfgbackup.
cfg#为Job(假设名称为shutdownGE)分配命令,以便将接口Ten-GigabitEthernet1/0/1关闭.
system-view[Sysname]schedulerjobshutdownGE[Sysname-job-shutdownGE]command1system-view[Sysname-job-shutdownGE]command2interfaceten-gigabitethernet1/0/1[Sysname-job-shutdownGE]command3shutdown【相关命令】schedulerjob1.
1.
6copyright-infoenablecopyright-infoenable命令用来开启版权信息显示功能.
undocopyright-infoenable命令用来关闭版权信息显示功能.
【命令】copyright-infoenableundocopyright-infoenable【缺省情况】版权信息显示功能处于开启状态.
【视图】系统视图【缺省用户角色】network-adminmdc-admin【举例】#开启版权信息显示功能.
system-view[Sysname]copyright-infoenable重新登录设备后,会显示如下信息:*Copyright(c)2004-2017NewH3CTechnologiesCo.
,Ltd.
Allrightsreserved.
**Withouttheowner'spriorwrittenconsent,**nodecompilingorreverse-engineeringshallbeallowed.
*1-71.
1.
7displayalarmdisplayalarm命令用来显示设备的告警信息.
【命令】(独立运行模式)displayalarm[slotslot-number](IRF模式)displayalarm[chassischassis-numberslotslot-number]【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【参数】slotslot-number:显示指定单板的告警信息.
slot-number表示单板所在的槽位号.
不指定该参数时,则表示所有单板.
(独立运行模式)chassischassis-numberslotslot-number:显示指定单板的告警信息.
chassis-number表示设备在IRF中的成员编号,slot-number表示单板所在的槽位号.
不指定该参数时,则表示IRF中的所有单板.
(IRF模式)【举例】#显示设备的告警信息.
(独立运行模式)displayalarmSlotCPULevelInfo10ERRORfaulty表1-1displayalarm命令显示信息描述表字段描述Slot产生告警的slot,显示为"-",表示产生告警的元件位于机框上CPU告警CPU的编号Level告警的级别,级别由高到低依次为ERROR、WARNING、NOTICE、INFOInfo告警的详细信息.
取值为:faulty:表示该slot处于faulty状态(该slot可能正在启动,或者当前处于故障状态)Fannisabsent:风扇n当前不在位Powernisabsent:电源n当前不在位Powernisfaulty:电源n处于异常状态Thetemperatureofsensornexceedsthelowerlimit:传感器n的温度低于低温门限Thetemperatureofsensornexceedstheupperlimit:传感器n的温度高于高温门限1-81.
1.
8displayasset-infodisplayasset-info命令用来显示设备的用户资产信息.
使用该命令,可以显示设备机箱、单板、风扇框或电源模块的资产信息.
【命令】(独立运行模式)displayasset-info{chassis|fanfan-id|powerpower-id|slotslot-number}[csn|custom|department|description|location|service-date|state](IRF模式)displayasset-infochassischassis-number{chassis|fanfan-id|powerpower-id|slotslot-number}[csn|custom|department|description|location|service-date|state]【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【参数】chassis:显示设备机箱的用户资产信息.
设备不支持配置本参数.
fanfan-id:显示指定风扇框的用户资产信息.
fan-id表示设备上风扇框的编号.
设备不支持配置本参数.
powerpower-id:显示指定电源模块的用户资产信息.
power-id表示设备上电源模块的编号.
设备不支持配置本参数.
slotslot-number:显示指定单板的用户资产信息.
slot-number表示设备上单板所在的槽位号.
csn:显示资产编号信息.
custom:显示用户自定义的资产信息.
department:显示资产的归属部门信息.
description:显示资产的描述信息.
location:显示资产的位置信息.
service-date:显示资产的启用时间信息.
state:显示资产的使用状态信息.
chassischassis-number:显示指定成员设备的用户资产信息.
chassis-number表示设备在IRF中的成员编号.
(IRF模式)【描述】当用户希望显示单板的具体信息项目(比如资产编号、资产描述信息等)时,只需要选择该信息项目对应的命令行参数;不选择具体信息项目对应的参数时,显示的是该单板的所有用户资产信息.
1-9使用该命令显示单板没有经过设置的具体信息项目时,该信息项目的内容显示为空.
【举例】#显示设备上0号单板的资产编号信息(该显示信息与用户的当前配置有关).
(独立运行模式)displayasset-infoslot0csnType:Slot0csn:123456#显示设备上0号单板的资产信息(该显示信息与用户的当前配置有关).
(独立运行模式)displayasset-infoslot0Type:Slot0csn:123456description:Slot0location:service-date:department:state:Normalcustom:1:789表1-2displayasset-info命令显示信息描述表字段描述Type资产类型,内容为指定的单板csn资产编号信息,内容为空表示用户没有进行设置description资产描述信息,内容为空表示用户没有进行设置location资产位置信息,内容为空表示用户没有进行设置service-date资产启用时间信息,内容为空表示用户没有进行设置department资产归属部门信息,内容为空表示用户没有进行设置state资产使用状态信息,内容为空表示用户没有进行设置custom用户自定义的资产信息,内容为空表示用户没有进行设置【相关命令】resetasset-infosetasset-info1.
1.
9displayclockdisplayclock命令用来显示系统当前的时间、日期、本地时区以及夏令时配置.
【命令】displayclock【视图】任意视图1-10【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【举例】#未配置本地时区时,显示系统当前日期和时间.
displayclock10:09:00UTCFri03/16/2015#配置了本地时区Z5后,显示系统当前日期和时间.
displayclock15:10:00Z5Fri03/16/2015TimeZone:Z5add05:00:00#配置了本地时区Z5和夏令时PDT后,显示系统当前日期和时间.
displayclock15:11:00Z5Fri03/16/2015TimeZone:Z5add05:00:00SummerTime:PDT06:00:0008/0106:00:0009/0101:00:00【相关命令】clockdatetimeclocktimezoneclocksummer-time1.
1.
10displaycopyrightdisplaycopyright命令用来显示设备的版权信息.
【命令】displaycopyright【视图】任意视图【缺省级别】network-adminnetwork-operatormdc-adminmdc-operator【举例】#显示设备的版权信息.
displaycopyright显示信息略…….
1-111.
1.
11displaycpu-usagedisplaycpu-usage命令用来显示CPU利用率的统计信息.
【命令】(独立运行模式)displaycpu-usage[summary][slotslot-number[cpucpu-number]](IRF模式)displaycpu-usage[summary][chassischassis-numberslotslot-number[cpucpu-number]]【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【参数】summary:以列表形式显示CPU利用率的统计信息.
不指定该参数时,以区段形式显示CPU利用率的统计信息.
slotslot-number:显示指定单板的CPU利用率的统计信息.
slot-number表示单板所在的槽位号.
不指定该参数时,显示的是所有单板的相应信息.
(独立运行模式)chassischassis-numberslotslot-number:显示指定成员设备指定单板的CPU利用率的统计信息.
chassis-number表示设备在IRF中的成员编号,slot-number表示单板所在的槽位号.
不指定该参数时,表示IRF中的所有单板.
(IRF模式)cpucpu-number:显示指定CPU的利用率统计信息.
cpu-number表示CPU的编号.
【使用指导】登录MDC后执行该命令,会显示该MDC可使用的CPU的利用率统计信息.
【举例】#以段的形式显示当前CPU利用率统计信息.
(独立运行模式)displaycpu-usageSlot1CPU0CPUusage:1%inlast5seconds1%inlast1minute1%inlast5minutes#以表的形式显示当前CPU利用率统计信息.
(独立运行模式)displaycpu-usagesummarySlotCPULast5secLast1minLast5min1017%29%28%1-12表1-3displaycpu-usage命令显示信息描述表字段描述1%inlast5seconds设备启动后,会以5秒为周期计算并记录一次该5秒内的CPU的平均利用率.
该字段显示的是最近一个5秒统计周期内CPU的平均利用率Last5sec设备启动后,会以5秒为周期计算并记录一次该5秒内的CPU的平均利用率.
该字段显示的是最近一个5秒统计周期内CPU的平均利用率1%inlast1minute设备启动后,会以1分钟为周期计算并记录一次该1分钟内的CPU的平均利用率.
该字段显示的是最近一个1分钟统计周期内CPU的平均利用率Last1min设备启动后,会以1分钟为周期计算并记录一次该1分钟内的CPU的平均利用率.
该字段显示的是最近一个1分钟统计周期内CPU的平均利用率1%inlast5minutes设备启动后,会以5分钟为周期计算并记录一次该5分钟内的CPU的平均利用率.
该字段显示的是最近一个5分钟统计周期内CPU的平均利用率Last5min设备启动后,会以5分钟为周期计算并记录一次该5分钟内的CPU的平均利用率.
该字段显示的是最近一个5分钟统计周期内CPU的平均利用率1.
1.
12displaycpu-usageconfigurationdisplaycpu-usageconfiguration命令用来显示CPU利用率历史信息记录功能的相关配置.
【命令】(独立运行模式)displaycpu-usageconfiguration[slotslot-number[cpucpu-number]](IRF模式)displaycpu-usageconfiguration[chassischassis-numberslotslot-number[cpucpu-number]]【视图】任意视图【缺省用户角色】network-adminmdc-admin【参数】slotslot-number:表示单板所在的槽位号.
不指定该参数时,显示的是主用主控板上的相应信息.
(独立运行模式)chassischassis-numberslotslot-number:表示指定成员设备上的指定单板.
不指定该参数时,显示的是全局主用主控板上的相应信息.
(IRF模式)cpucpu-number:表示CPU的编号.
【使用指导】登录MDC后执行该命令,会显示该MDC可使用的CPU的对应信息.
1-13【举例】#显示CPU利用率历史信息记录功能的相关配置.
displaycpu-usageconfigurationCPUusagemonitorisenabled.
Currentmonitorintervalis60seconds.
Currentmonitorthresholdis90%.
【相关命令】monitorcpu-usageenablemonitorcpu-usageintervalmonitorcpu-usagethreshold1.
1.
13displaycpu-usagehistorydisplaycpu-usagehistory命令用来以图表方式显示CPU利用率的历史信息.
【命令】(独立运行模式)displaycpu-usagehistory[jobjob-id][slotslot-number[cpucpu-number]](IRF模式)displaycpu-usagehistory[jobjob-id][chassischassis-numberslotslot-number[cpucpu-number]]【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【参数】jobjob-id:显示指定进程的CPU利用率的历史信息.
job-id表示进程的编号,取值范围为1~2147483647.
不指定该参数时,显示的是整个系统的相应信息(整个系统的CPU利用率等于所有进程CPU利用率之和).
可以使用displayprocess命令可以查看当前运行的进程的编号和名称,displayprocess命令的详细介绍请参见"网络管理与监控"中的"系统维护与调试".
slotslot-number:显示指定单板的CPU利用率的历史信息.
slot-number表示单板所在的槽位号.
当不指定job和该参数时,显示的是所有单板上所有进程的相应信息;当指定job参数,但不指定该参数时,显示的是主用主控板上指定进程的相应信息.
(独立运行模式)chassischassis-numberslotslot-number:显示指定成员设备上指定单板的CPU利用率的历史信息.
chassis-number表示设备在IRF中的成员编号,slot-number表示单板所在的槽位号.
当不指定job和该参数时,显示的是所有单板上所有进程的相应信息;当指定job参数,但不指定该参数时,显示的是全局主用主控板上指定进程的相应信息.
(IRF模式)1-14cpucpu-number:显示指定CPU的利用率的历史信息.
cpu-number表示CPU的编号.
当不指定job和该参数时,表示所有CPU.
当指定job参数,但不指定该参数时,表示默认CPU.
【使用指导】开启CPU利用率历史记录功能后,系统每隔一定时间(可通过monitorcpu-usageinterval命令配置)会对CPU的利用率进行采样,并把采样结果保存到历史记录区.
通过displaycpu-usagehistory命令可以查看到最近60个采样点的值.
结果以坐标的形式进行显示,显示信息中:纵坐标表示利用率,采用就近显示的原则.
比如,利用率的间隔为5%,则实际统计值53%将被显示成55%,实际统计值52%将被显示成50%.
横坐标表示时间,时间越靠左表示距离当前时间越近.
用连续的#号表示该时刻的利用率,某个时间点上最高处的#号对应的纵坐标值即为该时刻CPU的利用率.
登录MDC后执行该命令,会显示该MDC可使用的CPU的对应信息.
【举例】#以图表方式显示CPU利用率的历史记录.
(独立运行模式)displaycpu-usagehistory100%|95%|90%|85%|80%|75%|70%|65%|60%|55%|50%|45%|40%|35%|30%|25%|20%|15%|#10%|####5%102030405060(minutes)cpu-usage(Slot1CPU0)last60minutes(SYSTEM)以上显示信息表明系统(用"SYSTEM"表示,运行在Slot1CPU0上)在最近60分钟内CPU的利用率情况:12分钟前大约为5%,13分钟前大约为10%,14分钟前大约为15%,15分钟前大约为10%,16、17分钟前大约为5%,18分钟前大约为10%,19分钟前大约为5%,其它时间均小于或等于2%.
1-15【相关命令】monitorcpu-usageenablemonitorcpu-usageinterval1.
1.
14displaydevicedisplaydevice命令用来显示设备信息.
【命令】(独立运行模式)displaydevice[flash][slotslot-number|verbose](IRF模式)displaydevice[flash][chassischassis-number[slotslot-number]|verbose]【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【参数】flash:显示Flash的信息.
chassischassis-number:显示指定成员设备的详细信息.
chassis-number表示设备在IRF中的成员编号.
不指定该参数时,表示所有成员设备.
(IRF模式)slotslot-number:显示指定单板的信息.
slot-number表示单板所在的槽位号.
不指定该参数时,表示所有单板.
verbose:显示设备的详细信息.
不指定该参数时,显示设备的简要信息.
【使用指导】不指定flash参数时,显示单板的信息.
在缺省MDC和非缺省MDC下执行该命令,显示信息相同,且均显示物理设备的对应信息.
【举例】#显示设备信息.
(独立运行模式)displaydeviceSlotNo.
BrdTypeBrdStatusSubslotSftVerPatchVer0LSQM3MPUB0Master0S7500E-752102None1NONEAbsent0NONENone2LSQ1GP48EB0Normal0S7500E-752102None3NONEAbsent0NONENone4NONEAbsent0NONENone5NONEAbsent0NONENone6NONEAbsent0NONENone1-167NONEAbsent0NONENone表1-4displaydevice命令显示信息描述表(独立运行模式)字段描述SlotNo.
单板的槽位号BrdType单板的硬件类型BrdStatus单板状态:Standby表示该板是备用主控板Master表示该板是主用主控板Absent表示该槽位没有插入单板Fault表示该槽位单板出错,不能正常启动Normal表示该槽位单板是接口板并处于正常工作状态Subslot业务底板支持接口子卡的最大个数(暂不支持)SftVer当前单板上运行的软件版本PatchVer当前单板上运行的热补丁版本1.
1.
15displaydevicemanuinfodisplaydevicemanuinfo命令用来显示设备的电子标签信息.
【命令】(独立运行模式)displaydevicemanuinfo[slotslot-number](IRF模式)displaydevicemanuinfo[chassischassis-number[slotslot-number]]【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【参数】chassischassis-number:显示指定成员设备的电子标签信息.
chassis-number表示设备在IRF中的成员编号.
不输入该参数时,显示所有成员设备的相应信息.
(IRF模式)1-17slotslot-number:显示指定单板的电子标签信息.
slot-number表示单板所在的槽位号.
不输入该参数时,显示所有单板的相应信息.
【使用指导】电子标签信息也可以称为永久配置数据或档案信息等,在硬件的调测(调试、测试)过程中被写入到设备的存储器件中,包括硬件的名称、生产序列号、MAC地址、制造商等信息.
本命令仅缺省MDC支持.
【举例】#显示设备的电子标签信息.
displaydevicemanuinfo显示信息略…….
1.
1.
16displaydevicemanuinfochassis-onlydisplaydevicemanuinfochassis-only命令用来显示背板的电子标签信息.
【命令】(独立运行模式)displaydevicemanuinfochassis-only(IRF模式)displaydevicemanuinfochassischassis-numberchassis-only【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【参数】chassischassis-number:表示设备在IRF中的成员编号.
(IRF模式)【使用指导】本命令仅缺省MDC支持.
【举例】#显示机框背板的电子标签信息.
displaydevicemanuinfochassis-only显示信息略…….
1.
1.
17displaydevicemanuinfopowerdisplaydevicemanuinfopower命令用来显示电源的电子标签信息.
1-18【命令】(独立运行模式)displaydevicemanuinfopowerpower-id(IRF模式)displaydevicemanuinfochassischassis-numberpowerpower-id【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【参数】chassischassis-number:表示设备在IRF中的成员编号.
(IRF模式)power-id:表示设备上电源的ID编号.
【使用指导】本命令仅缺省MDC支持.
【举例】#显示指定电源的电子标签信息.
(独立运行模式)displaydevicemanuinfopower1显示信息略…….
【相关命令】1.
1.
18displaydiagnostic-informationdisplaydiagnostic-information命令用来收集诊断信息.
【命令】displaydiagnostic-information[hardware|infrastructure|l2|l3|service][key-info][filename]【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator1-19【参数】hardware:收集硬件相关的诊断信息.
infrastructure:收集基础模块的诊断信息.
l2:收集二层特性相关诊断信息.
l3:收集三层特性相关诊断信息.
service:收集上层业务模块相关诊断信息.
key-info:收集关键诊断信息.
当设备异常或者运行时间较长时,可能会产生较多诊断信息,此时,使用该关键字,即可以收集到关键的诊断信息,又可以缩短诊断信息的收集时间.
不指定该参数时,收集当前全部诊断信息.
filename:表示将收集到的诊断信息保存到指定文件.
filename表示文件的名称,后缀必须为".
tar.
gz".
不指定该参数时,用户可根据提示信息选择将诊断信息保存到指定文件或者是直接显示诊断信息.
【使用指导】在日常维护或系统出现故障时,为了便于问题定位,用户需要查看各个模块的诊断信息.
因为各个功能模块都有其对应的运行信息,所以一般情况下,用户需要逐条运行相应的display命令.
为便于一次性收集更多信息,用户可以在任意视图下执行displaydiagnostic-information命令,收集多个模块的诊断信息.
使用该命令,用户可以直接显示指定的诊断信息或者将诊断信息直接保存到指定文件,因为诊断信息较多,系统会自动将该文件压缩后保存,文件名后缀为".
tar.
gz".
如果要在设备上查看该文件的内容,请执行以下操作:(1)使用tarextract命令将文件XXXX.
tar.
gz解包成文件XXXX.
gz.
(2)使用gunzip命令将文件XXXX.
gz解包成文件XXXX.
(3)使用more命令查看文件XXXX的内容.
不指定filename参数执行displaydiagnostic-information命令时,系统会要求用户选择显示诊断信息还是将诊断信息保存到文件中.
如果用户选择保存诊断信息,且当系统提示用户输入文件名时直接回车,设备会自动将当前诊断信息保存到一个新文件,并使用设备名称和当前系统时间为该文件命名,以免和现有文件重名,导致现有文件被覆盖.
如果设备名称中包含"/"、"\"、":"、"*"、""、""、"|"、"""等特殊字符,在给诊断文件命名时,这些特殊字符会被转换为下划线"_".
比如设备的名称为A/B,设备会使用形如flash:/diag_A_B_20160101-000438.
tar.
gz的字符串为新生成的诊断文件命名.
未指定hardware、infrastructure、l2、l3和service参数时,将收集设备产生的所有诊断信息.
该命令不支持"|"、">"和">>"参数.
执行displaydiagnostic-information命令前,请使用displaycpu-usage、displaymemory命令查看CPU、内存使用率.
如果CPU使用率为100%,或者内存使用率超过90%,请暂时不要执行displaydiagnostic-information命令,等CPU和内存使用率回落后再执行.
执行本命令收集诊断信息时,请不要配置设备,以免影响收集结果.
【举例】#收集系统当前各个功能模块运行的统计信息.
displaydiagnostic-informationSaveordisplaydiagnosticinformation(Y=save,N=display)[Y/N]:n1-20displayclock=14:03:55UTCThu01/05/2015displayversion=显示信息略…….
#将收集到的诊断信息保存到缺省诊断文件.
displaydiagnostic-informationSaveordisplaydiagnosticinformation(Y=save,N=display)[Y/N]:yPleaseinputthefilename(*.
tar.
gz)[flash:/diag_Sysname_20160101-024601.
tar.
gz]:Diagnosticinformationisoutputtingtoflash:/diag_Sysname_20160101-024601.
tar.
gz.
Pleasewait.
.
.
Savesuccessfully.
请在"Pleaseinputthefilename"提示信息处,直接回车.
#将收集到的诊断信息保存到文件test.
tar.
gz.
displaydiagnostic-informationtest.
tar.
gzDiagnosticinformationisoutputtingtoflash:/test.
tar.
gz.
Pleasewait.
.
.
Savesuccessfully.
【相关命令】gunzip(基础配置命令参考/文件系统管理)more(基础配置命令参考/文件系统管理)tarextract(基础配置命令参考/文件系统管理)1.
1.
19displayenvironmentdisplayenvironment命令用来显示设备上温度传感器的温度信息.
【命令】(独立运行模式)displayenvironment[slotslot-number](IRF模式)displayenvironment[chassischassis-number[slotslot-number]]【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【参数】chassischassis-number:显示IRF中指定成员设备上温度传感器的温度信息.
chassis-number表示设备在IRF中的成员编号.
不指定该参数时,显示所有成员设备的对应信息.
(IRF模式)1-21slotslot-number:显示设备中指定单板上的温度传感器的温度信息.
slot-number表示单板所在的槽位号.
不指定该参数时,显示所有单板的对应信息.
【使用指导】不指定slot参数时,显示的是设备上所有温度传感器的温度信息.
(独立运行模式)不指定chassis参数时,显示的是IRF中所有温度传感器的温度信息;指定chassis但不指定slot参数时,显示的是指定成员设备上所有温度传感器的温度信息.
(IRF模式)本命令仅缺省MDC支持.
【举例】#显示设备上所有温度传感器的温度信息.
(独立运行模式)displayenvironmentSystemtemperatureinformation(degreecentigrade):SlotSensorTemperatureLowerWarningAlarmShutdown0inflow12806880NA0outflow13406880NA0hotspot144088100NA2hotspot135080971102hotspot241080971104hotspot13408097NA表1-5displayenvironment命令显示信息描述表字段描述SystemTemperatureinformation(degreecentigrade)系统温度信息,单位为摄氏度sensor温度传感器hotspot:表示热点温度传感器inflow:表示入风口温度传感器outflow:表示出风口温度传感器Slot当显示数字时表示指定slot上温度传感器的温度信息Temperature当前温度Lower低温告警门限.
当显示为NA时,表示不支持该门限Warning一般级(Warning)高温告警门限.
当显示为NA时,表示不支持该门限Alarm严重级(Alarm)高温告警门限.
当显示为NA时,表示不支持该门限Shutdown关断级(Shutdown)高温告警门限,当温度传感器的温度大于该门限时,设备会自动关闭.
当显示为NA时,表示不支持该门限1.
1.
20displayfandisplayfan命令用来显示风扇的工作状态.
1-22【命令】(独立运行模式)displayfan[fan-id](IRF模式)displayfan[chassischassis-number[fan-id]][verbose]【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【参数】chassischassis-number:表示设备在IRF中的成员编号.
不指定chassis参数时,表示所有风扇.
(IRF模式)fan-id:表示设备内置风扇的编号.
不指定该参数时,表示指定位置的所有风扇.
【使用指导】本命令仅缺省MDC支持.
【举例】#显示设备上所有风扇的工作状态.
displayfanFanFrame0State:Normal表1-6displayfan命令显示信息描述表字段描述FanFrame风扇框的编号State风扇状态:Absent:风扇不在位Normal:风扇正常工作Fault:风扇故障FanDirectionFault:用户期望的风道方向与风扇框的实际风道方向不一致AirflowDirection风扇模块的实际风道方向:Port-to-power:风扇从端口侧向电源侧抽风,即风向从前向后Power-to-port:风扇从电源侧向端口侧吹风,即风向从后向前PreferAirflowDirection用户期望的风扇模块的风道方向:Port-to-power:风扇从端口侧向电源侧抽风,即风向从前向后Power-to-port:风扇从电源侧向端口侧吹风,即风向从后向前1-231.
1.
21displayhardware-failure-detectiondisplayhardware-failure-detection命令用来显示设备的硬件故障检测和修复信息.
【命令】displayhardware-failure-detection【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【使用指导】displayhardware-failure-detection命令用来显示设备的硬件故障检测和修复信息,包括各种故障对应的修复操作,以及系统中每个单板最近十次故障修复的历史信息.
硬件故障检测和修复的历史信息保存在主用主控板上,即使某个槽位单板已拔出或者更换过,只要在主用主控板上已经保存,都可以通过displayhardware-failure-detection命令显示出来.
当主用主控板插拔或断电重启后,硬件故障检测和修复信息将会丢失.
(独立运行模式)硬件故障检测和修复的历史信息保存在本地主用主控板上,即使某个槽位单板已拔出或者更换过,只要在本地主用主控板上已经保存,都可以通过displayhardware-failure-detection命令显示出来.
当本地主用主控板插拔或断电重启后,硬件故障检测和修复信息将会丢失.
(IRF模式)本命令仅缺省MDC支持.
【举例】#查看设备的硬件故障检测和故障修复信息.
(独立运行模式)displayhardware-failure-detectionCurrentlevel:chip:isolateboard:isolateforwarding:warningRecentrecord:Slot0executedrecords:Thereisnorecord.
Slot0trappedrecords:Thereisnorecord.
表1-7displayhardware-failure-detection命令显示信息描述表字段说明Currentlevel当前故障检测对应的修复操作chip:器件类故障对应的修复操作board:单板类故障对应的修复操作1-24字段说明forwarding:转发类故障对应的修复操作Recentrecord:最近记录Slotnexecutedrecords:主控板n上记录的各个单板的历史操作记录(独立运行模式)Chassisn,Slotmexecutedrecords:成员设备n主控板m上记录的各个单板的历史操作记录(IRF模式)Slotntrappedrecords:主控板n上记录的各个单板的trap告警信息(独立运行模式)Chassisn,Slotmtrappedrecords:成员设备n主控板m上记录的各个单板的trap告警信息(IRF模式)1.
1.
22displayhardware-failure-protectiondisplayhardware-failure-protection命令用来显示设备上硬件故障保护的配置信息.
【命令】displayhardware-failure-protection[aggregation|port{auto-down|interface-typeinterface-number}]【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【参数】aggregation:显示聚合组的硬件故障保护配置信息.
port:显示端口硬件故障保护的配置信息.
auto-down:显示已配置端口硬件故障保护的端口列表.
interface-typeinterface-number:显示指定端口上硬件故障保护的配置信息.
【使用指导】如果不带参数,则显示设备上所有硬件故障保护的配置信息,包括是否配置了针对聚合组的硬件故障保护和所有配置了端口硬件故障保护的端口列表.
如要显示非缺省MDC下的以太网接口硬件故障保护的配置信息,需要登录对应的MDC,再执行此命令.
【举例】#显示设备上所有硬件故障保护的配置信息.
displayhardware-failure-protectionAggregation:on1-25Port:XGE1/0/1XGE1/0/2#显示配置了端口硬件故障保护的端口列表.
displayhardware-failure-protectionportauto-downPort:XGE1/0/1XGE1/0/2#显示端口XGE1/0/2是否配置了硬件故障保护.
displayhardware-failure-protectionportten-gigabitethernet1/0/2Auto-downisNOTallowedwhilehardware-failurehappened.
表1-8displayhardware-failure-protection命令显示信息描述表字段说明Aggregation显示是否配置了针对聚合组的硬件故障保护功能.
取值为:on:表示针对聚合组的硬件故障保护功能处于开启状态off:表示针对聚合组的硬件故障保护功能处于关闭状态Port:显示配置了端口硬件故障保护的端口列表1.
1.
23displaymemorydisplaymemory命令用来显示内存使用情况.
【命令】(独立运行模式)displaymemory[summary][slotslot-number[cpucpu-number]](IRF模式)displaymemory[summary][chassischassis-numberslotslot-number[cpucpu-number]]【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【参数】summary:显示内存使用情况的简要信息.
不指定该参数时,显示内存使用情况的详细信息.
slotslot-number:表示单板所在的槽位号,不指定时显示当前所有单板的内存使用情况.
(独立运行模式)chassischassis-numberslotslot-number:表示指定成员设备上的指定单板.
chassis-number表示设备在IRF中的成员编号,slot-number表示单板所在的槽位号.
不指定该参数时,表示所有主控板.
(IRF模式)cpucpu-number:表示CPU编号.
1-26【使用指导】登录MDC后执行该命令,会显示该MDC可使用的内存的使用情况.
【举例】#显示设备的内存使用情况的详细信息.
(独立运行模式)displaymemoryMemorystatisticsaremeasuredinKB:Slot1:TotalUsedFreeSharedBuffersCachedFreeRatioMem:984560456128528432044561653.
7%-/+Buffers/Cache:410508574052Swap:000LowMem:73982437555236427249.
2%HighMem:2447368057616416067.
1%#显示设备的内存使用情况的简要信息.
(独立运行模式)displaymemorysummarydismemorysummaryMemorystatisticsaremeasuredinKB:SlotCPUTotalUsedFreeBuffersCachesFreeRatio1098456045612852843244561653.
7%LowmemorystatisticsaremeasuredinKB:SlotCPUTotalUsedFreeBuffersCachesFreeRatio10739824375552364272----49.
2%HighmemorystatisticsaremeasuredinKB:SlotCPUTotalUsedFreeBuffersCachesFreeRatio1024473680576164160----67.
1%表1-9displaymemory命令显示信息描述表字段描述MemorystatisticsaremeasuredinKB:系统内存使用情况,以下统计信息均以KB为单位Mem内存使用信息Total系统可分配的物理内存的大小设备总物理内存分为不可分配物理内存和可分配物理内存.
其中,不可分配物理内存用于内核代码段存储、内核管理开销以及ISSU功能运行等;可分配物理内存用于支撑业务模块的运行、文件存储等操作.
不可分配内存的大小由设备根据系统运行需要自动计算划分,可分配物理内存的大小等于设备总物理内存减去不可分配内存的大小Used整个系统已用的物理内存大小Free整个系统可用的物理内存大小Shared多个进程共享的物理内存总额.
取值为"--"时,表示不支持统计该参数的值Buffers已使用的文件缓冲区的大小.
取值为"--"时,表示不支持统计该参数的值Cached高速缓冲寄存器已使用的内存大小.
取值为"--"时,表示不支持统计该参数的值1-27字段描述Caches高速缓冲寄存器已使用的内存大小FreeRatio整个系统物理内存的空闲率-/+buffers/cache-/+Buffers/Cache:used=Mem:Used–Mem:Buffers–Mem:Cached,表示应用程序已用的物理内存大小-/+Buffers/Cache:free=Mem:Free+Mem:Buffers+Mem:Cached,表示应用程序可用的物理内存大小Swap交换分区的使用信息LowMem低端内存使用信息HighMem高端内存使用信息1.
1.
24displaymemory-thresholddisplaymemory-threshold命令用来显示内存告警门限相关信息.
【命令】(独立运行模式)displaymemory-threshold[slotslot-number[cpucpu-number]](IRF模式)displaymemory-threshold[chassischassis-numberslotslot-number[cpucpu-number]]【视图】任意视图【缺省用户角色】network-adminmdc-admin【参数】slotslot-number:表示单板所在的槽位号.
不指定该参数时,表示主用主控板.
(独立运行模式)chassischassis-numberslotslot-number:表示指定成员设备上的指定单板.
chassis-number表示设备在IRF中的成员编号,slot-number表示单板所在的槽位号.
不指定该参数时,表示全局主用主控板.
(IRF模式)cpucpu-number:表示CPU编号.
【使用指导】当设备已经使用的物理内存大小超过内存某个告警门限阈值时,系统会认为发生了一次该类型内存异常,并记录第一次、最近一次发生异常的时间,以及这段时间内发生的该类异常的次数.
如果想了解该类异常的详细情况,请查看日志信息,可按日志摘要关键字"MEM_EXCEED_THRESHOLD"或"MEM_BELOW_THRESHOLD"进行搜索.
【举例】#显示内存告警门限相关信息.
1-28displaymemory-thresholdMemoryusagethreshold:100%Free-memorythresholds:Minor:96MSevere:64MCritical:48MNormal:128MEarly-warning:256MSecure:304MCurrentfree-memorystate:Normal(secure)Free-memoryeventstatistics:[Backtosecurestate]Firstnotification:0.
0Latestnotification:0.
0Totalnumberofnotificationssent:0[Enteredearly-warningstate]Firstnotificationat:0.
0Latestnotificationat:0.
0Totalnumberofnotificationssent:0[Backtonormalstate]Firstnotification:0.
0Latestnotification:0.
0Totalnumberofnotificationssent:0[Enteredminoralarmstate]Firstnotificationat:0.
0Latestnotificationat:0.
0Totalnumberofnotificationssent:0[Backtominoralarmstate]Firstnotificationat:0.
0Latestnotificationat:0.
0Totalnumberofnotificationssent:0[Enteredseverealarmstate]Firstnotificationat:0.
0Latestnotificationat:0.
0Totalnumberofnotificationssent:0[Backtoseverealarmstate]Firstnotificationat:0.
0Latestnotificationat:0.
0Totalnumberofnotificationssent:0[Enteredcriticalalarmstate]Firstnotificationat:0.
0Latestnotificationat:0.
0Totalnumberofnotificationssent:0表1-10displaymemory-threshold命令显示信息描述表字段描述Memoryusagethreshold内存利用率阈值1-29字段描述Free-memorythresholdsMinorSevereCriticalNormalEarly-warningSecure剩余内存门限阈值:Minor:一级告警门限,单位为MBSevere:二级告警门限,单位为MBCritical:三级告警门限,单位为MBNormal:恢复到正常状态的阈值,单位为MBCurrentfree-memorystate系统当前内存使用状态:Normal:正常状态Minor:一级告警门限状态Severe:二级告警门限状态Critical:三级告警门限状态Free-memoryeventstatistics:门限事件统计信息,事件分为:Backtonormalstate:内存恢复到正常状态Enteredminoralarmstate:进入一级告警门限状态Backtominoralarmstate:恢复到一级告警前的状态Enteredseverealarmstate:进入二级告警门限状态Backtoseverealarmstate:恢复到二级告警前的状态Enteredcriticalalarmstate:进入三级告警门限状态Firstnotificationat事件第一次发生的时间,格式yyyy-mm-ddhh:mm:ss.
msecLatestnotificationat事件最近一次发生的时间,格式yyyy-mm-ddhh:mm:ss.
msecTotalnumberofnotificationsend事件发生的总次数1.
1.
25displaypower-supplydisplaypower-supply命令用来显示设备电源的信息.
【命令】(独立运行模式)displaypower-supply[verbose](IRF模式)displaypower-supply[chassischassis-number][verbose]【视图】任意视图【缺省用户角色】network-adminnetwork-operator1-30【参数】chassischassis-number:显示指定成员设备上电源的信息.
chassis-number表示设备在IRF中的成员编号.
不指定该参数时,表示所有成员设备.
(IRF模式)verbose:显示电源的详细信息.
不指定该参数时,显示电源的简要信息.
【举例】#显示电源简要信息.
(独立运行模式)displaypower-supplyPower0State:AbsentPower1State:NormalPower2State:AbsentPower3State:Absent#显示电源详细信息.
displaypower-supplyverbosePowerinfo:DevicePower:2500WattsFanPower:240WattsSurpluspower:2020WattsSystempowerinfo:PowerNo.
PowerSizePower12500WattsSlotpowerinfo:SlotNo.
Power(Watts)050--ReservedforstandbyMPU.
150360780表1-11displaypower-supply命令显示信息描述表字段描述PowernState电源模块的状态:Normal:表示该槽位电源模块处于正常工作状态Absent:表示该槽位没有插入电源模块Error:表示该槽位电源模块出错,不能正常运行Powerinfo电源的信息DevicePower设备的系统总功率FanPower风扇的最大功率Surpluspower设备的剩余功率Systempowerinfo系统的电源信息PowerNo.
电源编号PowerSize电源功率大小1-31字段描述Slotpowerinfo单板的电源信息SlotNo.
单板的槽位号Power(Watts)单板的最大功率ReservedforstandbyMPU主控板的保留功率1.
1.
26displayschedulerjobdisplayschedulerjob命令用来显示Job的配置信息.
【命令】displayschedulerjob[job-name]【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【参数】job-name:Job的名称,为1~47个字符的字符串,区分大小写.
不指定该参数时,则显示所有Job的配置信息.
【举例】#查看所有Job的配置信息.
displayschedulerjobJobname:saveconfigcopystartup.
cfgbackup.
cfgJobname:backupconfigJobname:creat-VLAN100system-viewvlan100以上显示信息表明,设备当前配置了3个Job,分别显示了Job的名称,以及为Job分配的命令(如果没有为Job分配命令,则只显示Job的名称),不同Job间用空行分隔.
1.
1.
27displayschedulerlogfiledisplayschedulerlogfile命令用来显示Job的执行日志信息.
1-32【命令】displayschedulerlogfile【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【举例】#显示Schedule日志文件的相关信息.
displayschedulerlogfileLogfileSize:1902Bytes.
Jobname:shutdownSchedulename:shutdownExecutiontime:TueDec2710:44:422015Completiontime:TueDec2710:44:472015Joboutputsystem-viewSystemView:returntoUserViewwithCtrl+Z.
[Sysname]interfacerangten-gigabitethernet1/0/1toten-gigabitethernet1/0/3[Sysname-if-range]shutdown表1-12displayschedulerlogfile命令显示信息描述表字段描述LogfileSizeSchedule日志文件的大小,单位为字节JobnameJob的名称SchedulenameSchedule的名称Executiontime开始执行Job的时间CompletiontimeJob执行结束的时间(没有调度的或者没有分配命令的Job,均不会显示该信息)JoboutputJob中的命令执行时的输出信息【相关命令】resetschedulerlogfile1.
1.
28displayschedulerrebootdisplayschedulerreboot命令用来显示定时重启功能的相关配置.
1-33【命令】displayschedulerreboot【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【举例】#显示定时重启功能的相关配置.
displayschedulerrebootSystemwillrebootat16:32:0005/23/2015(in1hoursand39minutes).
【相关命令】schedulerrebootatschedulerrebootdelay1.
1.
29displayschedulerscheduledisplayschedulerschedule命令用来显示Schedule的相关信息.
【命令】displayschedulerschedule[schedule-name]【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【参数】schedule-name:Schedule的名称,为1~47个字符的字符串,区分大小写.
如果不指定该参数,则显示所有Schedule的信息.
【举例】#显示所有Schedule的信息.
displayschedulerscheduleSchedulename:shutdownScheduletype:Runonceafter0hours2minutesStarttime:TueDec2710:44:4220151-34Lastexecutiontime:TueDec2710:44:422015Lastcompletiontime:TueDec2710:44:472015Executioncounts:1JobnameLastexecutionstatusshutdownSuccessful表1-13displayschedulerschedule命令显示信息描述表字段描述SchedulenameSchedule的名称ScheduletypeSchedule的执行时间配置.
如果没有为Schedule配置执行时间,则不会显示该信息StarttimeSchedule第一次开始执行的时间.
如果没有为Schedule配置执行时间,则不会显示该信息LastexecutiontimeSchedule上一开始执行的时间如果没有为Schedule配置执行时间,则不会显示该信息如果还没有执行,则显示YettobeexecutedLastcompletiontimeSchedule上一次执行完成的时间.
如果没有为Schedule配置执行时间,则不会显示该信息ExecutioncountsSchedule已经执行的次数.
如果Schedule还没有执行,则不会显示该信息JobnameSchedule下关联的Job的名称LastexecutionstatusJob上一次被执行的状态(Job下分配的命令是否执行以及执行结果,请通过displayschedulerlogfile命令查看)Successful:表示执行成功Failed:表示执行失败Waiting:表示正在等待被执行Inprocess:表示正在执行-NA-:表示还没有到执行时间1.
1.
30displayswitch-modestatusdisplayswitch-modestatus用于查看所有单板当前的工作模式和代理模式以及单板配置的工作模式和代理模式.
【命令】(独立运行模式)displayswitch-modestatus(IRF模式)displayswitch-modestatuschassischassis-number【视图】任意视图1-35【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【参数】chassischassis-number:显示指定成员设备上所有单板当前的工作模式和代理模式以及单板配置的工作模式和代理模式.
chassis-number表示设备在IRF中的成员编号.
(IRF模式)【使用指导】使用undoswitch-mode命令将单板的工作模式和代理模式恢复到未配置状态(即Config显示为NONE),保存配置并重启该单板后,单板将以缺省的工作模式启动.
【举例】#查看交换机所有单板当前的工作模式和代理模式以及单板配置的工作模式和代理模式.
(独立运行模式)displayswitch-modestatusLPUswitchmodeandproxymode:SlotCurrentConfig0MIX[NONE]NONE[NONE]2NORMAL[NONE]NONE[NONE]3NONE[NONE]NONE[NONE]CurrentFabricMode:compatibleNextFabricMode:compatible表1-14displayswitch-modestatus显示信息描述表字段说明Slot单板槽位号LPUswitchmodeandproxymode单板的工作模式和代理模式1-36字段说明Current单板当前的工作模式或代理模式:NONE:不支持配置单板的工作模式或代理模式BALANCE:业务板当前的工作模式为均衡模式BRIDGING:单板当前的工作模式为MAC扩展模式ENHANCE-BRIDGING:业务板当前的工作模式为增强的MAC扩展模式NORMAL:单板当前的工作模式为普通模式ROUTING:单板当前的工作模式为路由扩展模式MIX:单板当前的工作模式为混合扩展模式IPv6:单板当前的工作模式为IPv6模式STANDARD-IPV6:单板当前的工作模式为IPv6标准模式ROUTE-HIGH:单板当前的代理模式为单板路由代理模式,即route-proxy-high模式ROUTE-LOW:单板当前的代理模式为单板路由被代理模式,即route-proxy-low模式ADJ-HIGH:单板当前的代理模式为ARP/ND代理模式,即adj-proxy-high模式ADJ-LOW:单板当前的代理模式为单板ARP/ND被代理模式,即adj-prxoy-low模式L3-HIGH:单板当前的代理模式为单板路由/ARP/ND代理模式,即l3-proxy-high模式Config单板配置的工作模式或代理模式:NONE:目前没有对单板配置工作模式或代理模式BALANCE:业务板配置的工作模式为均衡模式BRIDGING:单板配置的工作模式为MAC扩展模式ENHANCE-BRIDGING:业务板配置的工作模式为增强的MAC扩展模式NORMAL:单板配置的工作模式为普通模式ROUTING:单板配置的工作模式为路由扩展模式MIX:单板配置的工作模式为混合扩展模式IPv6:单板当前的工作模式为IPv6模式STANDARD-IPV6:单板配置的工作模式为IPv6标准模式ROUTE-HIGH:单板配置的代理模式为单板路由代理模式,即route-proxy-high模式ROUTE-LOW:单板配置的代理模式为单板路由被代理模式,即route-proxy-low模式ADJ-HIGH:单板配置的代理模式为ARP/ND代理模式,即adj-proxy-high模式ADJ-LOW:单板配置的代理模式为单板ARP/ND被代理模式,即adj-prxoy-low模式L3-HIGH:单板配置的代理模式为单板路由/ARP/ND代理模式,即l3-proxy-high模式*indicatesthemodeisnotsupported.
*表示插入某一槽位的单板不支持该槽位已配置的工作模式,单板将以缺省工作模式启动1-37字段说明CurrentFabricMode当前业务板槽位转发模式standard-mode:将业务板槽位转发模式设置为标准模式high-speed-mode:将业务板槽位转发模式设置为高速模式NextFabricMode下次业务板槽位转发模式standard-mode:将业务板槽位转发模式设置为标准模式high-speed-mode:将业务板槽位转发模式设置为高速模式【相关命令】switch-modefabric-mode1.
1.
31displaysystemstablestatedisplaysystemstablestate命令用来显示系统的稳定状态.
【命令】displaysystemstablestate[mdc{mdc-id|all}]【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【参数】mdc{mdc-id|all}:显示指定或所有MDC的系统稳定状态.
mdc-id表示MDC的编号,MDC的取值范围为1~5.
【使用指导】不指定mdc参数时,显示系统的稳定状态.
在进行ISSU升级或主备倒换前,请先执行该命令,检查设备是否处于稳定状态.
如果SystemState未处于Stable状态,不能进行ISSU升级;如果RedundancyStable未处于Stable状态,不能进行主备倒换.
设备/单板/MDC启动需要一定的时间,才能达到Stable状态.
如果设备/单板/MDC长时间未能进入Stable状态,可通过该命令的显示信息找出未稳定的设备/单板/MDC,根据其具体状态,采取进一步措施.
系统处于不稳定状态时,需要结合相关命令查看设备的具体情况.
例如:通过displaydevice命令查看设备是否处于故障状态.
通过displayhaservice-group命令查看HA服务组的状态,以找出未批备完成的模块.
1-38通过Probe视图下的displaysysteminternalprocessstate命令查看服务启动状态.
操作时,建议多次执行命令,以确认稳定状态的连续性.
【举例】#显示系统的稳定状态.
(独立运行模式)displaysystemstablestateSystemstate:StableRedundancystate:StableSlotCPURoleState00ActiveStable10StandbyStable30OtherStable150OtherStable表1-15displaysystemstablestate命令显示信息描述表字段描述Systemstate系统状态:Stable:稳定运行Notready:未稳定,此时不能进行ISSU升级Redundancystate主备状态:Stable:主备状态稳定,可以倒换Noredundance:系统无冗余,不能倒换Notready:未稳定,不可以倒换Role单板在系统中的身份:Active:主用主控板Standby:备用主控板,提供冗余备份Other:业务板State单板状态:Stable:单板稳定运行Boardinserted:单板插入Kernelinitiating:单板内核初始化Servicestarting:单板上的服务正在启动Servicestopping:单板上的服务正在关闭HABatchbackup:HA批量备份中Interfacedatabatchbackup:接口管理批量备份未完成MDCstarting:MDC正在启动MDCstopping:MDC正在关闭*当前对象处于未稳定状态【相关命令】displaydevice1-39displayhaservice-group(可靠性命令参考/进程分布优化)displaymdc(虚拟化技术命令参考/MDC)1.
1.
32displaysystem-working-modedisplaysystem-working-mode命令用来显示设备的工作模式.
【命令】displaysystem-working-mode【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【举例】#显示设备的工作模式.
displaysystem-working-modeThecurrentsystemworkingmodeisstandard.
Thesystemworkingmodefornextstartupisstandard.
1.
1.
33displaytransceiveralarmdisplaytransceiveralarm命令用来显示可插拔接口模块的当前故障告警信息.
【命令】displaytransceiveralarminterface[interface-typeinterface-number]【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【参数】interface[interface-typeinterface-number]:显示接口上插入的可插拔接口模块的当前故障告警信息.
interface-typeinterface-number表示接口类型和接口编号,如果不指定该参数,表示所有接口.
1-40【使用指导】目前,使用的可插拔接口模块可能出现的故障告警信息见"displaytransceiveralarm命令输出信息描述表".
如果没有故障,则显示为None.
表1-16SFP/SFP+的displaytransceiveralarm命令输出信息描述表字段描述RXlossofsignal接收信号丢失RXpowerhigh接收光功率高RXpowerlow接收光功率低TXfault发送错误TXbiashigh偏置电流高TXbiaslow偏置电流低TXpowerhigh发送光功率高TXpowerlow发送光功率低Temphigh温度高Templow温度低Voltagehigh电压高Voltagelow电压低TransceiverinfoI/Oerror模块信息读写错误Transceiverinfochecksumerror模块信息校验和错误Transceivertypeandportconfigurationmismatch模块类型和端口配置不匹配Transceivertypenotsupportedbyporthardware端口不支持该模块类型TECfaultTEC(ThermoelectricCooler,热点冷却器)错误.
仅HPEX13010GSFP+LCLH80tunableTransceiver(JL250A)光模块支持显示该信息Wavelengthunlocked光信号波长失锁.
仅HPEX13010GSFP+LCLH80tunableTransceiver(JL250A)光模块支持显示该信息Txisnotreadyduetotunning光信号波长改变时发射端处于准备过程状态告警.
仅HPEX13010GSFP+LCLH80tunableTransceiver(JL250A)光模块支持显示该信息表1-17QSFP+的displaytransceiveralarm命令输出信息描述表字段描述Temphigh温度高Templow温度低Voltagehigh电压高Voltagelow电压低1-41字段描述RXsignallossinchannelx通道x接收到的信号丢失TXfaultinchannelx通道x发送报文时出错TXsignallossinchannelx通道x发送的信号丢失RXpowerhighinchannelx通道x接收到的光的功率太高RXpowerlowinchannelx通道x接收到的光的功率太低TXbiashighinchannelx通道x的偏置电流高TXbiaslowinchannelx通道x的偏置电流低TransceiverinfoI/Oerror模块读写错误Transceiverinfochecksumerror模块信息校验和错误Transceivertypeandportconfigurationmismatched模块类型和端口配置不匹配Transceivertypenotsupported端口不支持该类型的模块【举例】#显示接口GigabitEthernet1/0/1上插入的可插拔接口模块的当前故障告警信息.
displaytransceiveralarminterfacegigabitethernet1/0/1GigabitEthernet1/0/1transceivercurrentalarminformation:RXlossofsignalRXpowerlow表1-18displaytransceiveralarm显示信息描述表字段描述transceivercurrentalarminformation接口光模块当前故障告警信息RXlossofsignal接收信号丢失RXpowerlow接收光功率低告警1.
1.
34displaytransceiverdiagnosisdisplaytransceiverdiagnosis命令用来显示可插拔光模块的数字诊断参数的当前测量值.
【命令】displaytransceiverdiagnosisinterface[interface-typeinterface-number]【视图】任意视图【缺省用户角色】network-adminnetwork-operator1-42mdc-adminmdc-operator【参数】interface[interface-typeinterface-number]:显示接口上插入的可插拔光模块的数字诊断参数的当前测量值.
interface-typeinterface-number表示接口类型和接口编号,如果不指定该参数,表示所有接口.
【举例】#显示接口GigabitEthernet1/0/1上插入的可插拔光模块的数字诊断参数的当前测量值.
displaytransceiverdiagnosisinterfacegigabitethernet1/0/1GigabitEthernet1/0/1transceiverdiagnosticinformation:Currentdiagnosticparameters:Temp(°C)Voltage(V)Bias(mA)RXpower(dBm)TXpower(dBm)363.
316.
13-35.
64-5.
19Alarmthresholds:Temp(℃)Voltage(V)Bias(mA)RXpower(dBM)TXpower(dBM)High503.
551.
44-10.
005.
00Low303.
011.
01-30.
000.
00表1-19displaytransceiverdiagnosis显示信息描述表字段描述transceiverdiagnosticinformation接口插入的光模块的数字诊断信息Currentdiagnosticparameters当前的诊断参数Wave.
er(nm)波长偏移,单位为nm,精确到0.
001nm.
仅HPEX13010GSFP+LCLH80tunableTransceiver(JL250A)光模块支持显示该字段Freq.
er(GHz)频率偏移,单位为GHZ,精确到0.
1GHZ.
仅HPEX13010GSFP+LCLH80tunableTransceiver(JL250A)光模块支持显示该字段Temp.
(°C)数字诊断参数——温度,单位为°C,精确到1°CVoltage(V)数字诊断参数——电压,单位为V,精确到0.
01VBias(mA)数字诊断参数——偏置电流,单位为mA,精确到0.
01mARXpower(dBm)数字诊断参数——接收光功率,单位为dBm,精确到0.
01dBmTXpower(dBm)数字诊断参数——发送光功率,单位为dBm,精确到0.
01dBmAlarmthresholds告警门限High高告警门限Low低告警门限1.
1.
35displaytransceiverinterfacedisplaytransceiverinterface命令用来显示可插拔接口模块的主要特征参数.
1-43【命令】displaytransceiverinterface[interface-typeinterface-number]【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【参数】interface-typeinterface-number:显示接口上插入的可插拔接口模块的主要特征参数.
interface-typeinterface-number表示接口类型和接口编号,如果不指定该参数,表示所有接口.
【举例】#显示接口Ten-GigabitEthernet3/0/45上插入的可插拔接口模块的主要特征参数.
displaytransceiverinterfaceten-gigabitethernet3/0/45Ten-GigabitEthernet3/0/45transceiverinformation:TransceiverType:10G_BASE_SR_SFPConnectorType:LCWavelength(nm):850TransferDistance(m):80(OM2),20(OM1),300(OM3)DigitalDiagnosticMonitoring:YESVendorName:FINISARCORP.
1.
1.
36displaytransceivermanuinfodisplaytransceivermanuinfo命令用于显示可插拔接口模块的电子标签信息.
【命令】displaytransceivermanuinfointerface[interface-typeinterface-number]【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【参数】interface[interface-typeinterface-number]:显示接口上插入的可插拔接口模块的部分电子标签信息.
interface-typeinterface-number表示接口类型和接口编号,如果不指定该参数,表示所有接口.
1-44【举例】#显示接口GigabitEthernet1/0/1上插入的可插拔接口模块的电子标签信息.
displaytransceivermanuinfointerfacegigabitethernet1/0/1显示信息略…….
1.
1.
37displayversiondisplayversion命令用来显示系统版本信息.
【命令】displayversion【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【举例】#查看系统版本信息.
displayversion显示信息略…….
1.
1.
38displayversion-update-recorddisplayversion-update-record命令用来显示启动软件包版本更新操作的记录.
【命令】displayversion-update-record【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【使用指导】设备启动时会记录当前使用的启动软件包版本信息,如果在运行过程中进行启动软件包版本更新操作,系统会记录该次更新的简要信息,包括升级时间和版本,以便管理员了解相关信息.
设备重启这些记录也不会被删除.
1-45【举例】#显示设备启动软件包版本更新操作的记录.
displayversion-update-recordRecord1(updatedonApr182015at06:23:54):*Name:simware-cmw710-boot.
binVersion:7.
1.
070Test0001Compiletime:Mar25201515:52:43*Name:simware-cmw710-system.
binVersion:7.
1.
070Test0001Compiletime:Mar25201515:52:43表1-20displayversion-update-record命令显示信息描述表字段描述Recordn(updatedonApr182014at06:23:54)最近的第n次更新的时间,Record1为最新的一次更新*Name软件包的名称.
带*符号,表示软件包的版本和升级前的版本有变化;不带*符号,表示版本没有变化Version软件包的版本号Compiletime版本编译时间【相关命令】resetversion-update-record1.
1.
39displayxbardisplayxbar命令用来显示主控板的负载模式.
【命令】(独立运行模式)displayxbar(IRF模式)displayxbar[chassischassis-number]【视图】任意视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator1-46【参数】chassischassis-number:用来显示指定成员设备上主用主控板和备用主控板的负载模式.
chassis-number表示设备在IRF中的成员编号.
不指定该参数时,显示所有成员设备的对应信息.
(IRF模式)【使用指导】配置的负载模式和当前运行的负载模式不一定相同.
只有主用主控板和备用主控板同时在位时,配置的负载分担模式才会生效;否则,即便配置了负载分担模式,主用主控板也会自动切换到独立负载模式.
S7502E、S7503E-M设备不支持本命令.
【举例】#显示设备主用主控板和备用主控板的负载模式.
(独立运行模式)displayxbarTheconfiguredsystemHAxbarloadmodeisBALANCETheactivatedsystemHAxbarloadmodeisSINGLE以上显示信息表明:当前系统配置的负载模式为负载分担模式,但实际生效的是独立负载模式.
【相关命令】xbar1.
1.
40fabricload-sharingmodefabricload-sharingmode命令用来配置业务板的负载分担类型.
undofabricload-sharingmode命令用来恢复缺省情况.
【命令】(独立运行模式)fabricload-sharingmode{{destination-ip|destination-mac|ingress-port|source-ip|source-mac}*|flexible}slotslot-numberundofabricload-sharingmodeslotslot-number(IRF模式)fabricload-sharingmode{{destination-ip|destination-mac|ingress-port|source-ip|source-mac}*|flexible}chassischassis-numberslotslot-numberundofabricload-sharingmodechassischassis-numberslotslot-number【缺省情况】本命令的缺省情况请参见"基础配置指导"中的"设备管理".
【视图】系统视图【缺省用户角色】network-adminmdc-admin1-47【参数】destination-ip:表示按报文的目的IP地址进行负载分担.
destination-mac:表示按报文的目的MAC地址进行负载分担.
ingress-port:表示按报文的入端口进行负载分担.
source-ip:表示按报文的源IP地址进行负载分担.
source-mac:表示按报文的源MAC地址进行负载分担.
flexible:表示按报文类型(如二层、IPv4等)自动选择负载分担的类型.
slotslot-number:单板所在的槽位号.
(独立运行模式)chassischassis-numberslotslot-number:chassis-number表示设备在IRF中的成员编号,slot-number为单板所在的槽位号.
(IRF模式)【使用指导】如果多次执行本命令,最后一次执行的命令生效.
【举例】#配置指定slot按照报文目的MAC地址进行负载分担.
(独立运行模式)system-view[Sysname]fabricload-sharingmodedestination-macslot21.
1.
41fabric-modefabric-mode命令用来配置业务板槽位上的转发模式.
undofabric-mode命令用来恢复缺省情况.
【命令】(独立运行模式)fabric-mode{high-speed-mode|standard-mode}undofabric-mode(IRF模式)fabric-mode{high-speed-mode|standard-mode}chassischassis-numberundofabric-modechassischassis-number【缺省情况】设备工作在标准模式.
【视图】系统视图【缺省用户角色】network-adminmdc-admin【参数】standard-mode:将业务板槽位上的转发模式设置为标准模式.
high-speed-mode:将业务板槽位上的转发模式设置为高速模式.
1-48chassischassis-number:设置指定成员设备的业务板槽位上的转发模式.
chassis-number表示设备在IRF中的成员编号.
(IRF模式)【使用指导】仅安装了LSQM2MPUC0主控板的S7510E设备支持该命令.
不同模式下,S7510E业务板槽位支持的单板类型和槽位最大带宽不同,详细介绍请参见"基础配置指导"中的"设备管理".
要使修改的业务板槽位上的转发模式生效,必须重启设备.
本命令仅在缺省MDC下支持.
有关MDC的详细介绍,请参见"虚拟化技术配置指导"中的"MDC".
【举例】#将业务板槽位上的转发模式配置为标准模式.
system-view[Sysname]fabric-modestandard-modeThiscommandmayneedrebootthedevice.
Continue[Y/N]:yProcessOK.
【相关命令】displayswitch-modestatusreboot1.
1.
42forward-path-detectionenableforward-path-detectionenable命令用来开启转发通道自动检测功能.
undoforward-path-detectionenable命令用来关闭转发通道自动检测功能.
【命令】forward-path-detectionenableundoforward-path-detectionenable【缺省情况】转发通道自动检测功能处于开启状态.
【视图】系统视图【缺省用户角色】network-adminmdc-admin【使用指导】转发通道自动检测功能可以检测设备中的数据转发通道是否正常.
如果不正常,会打印日志信息提醒用户.
本命令仅缺省MDC支持.
【举例】#开启转发通道自动检测功能.
1-49system-view[Sysname]forward-path-detectionenable1.
1.
43hardware-failure-detectionhardware-failure-detection命令用来配置当系统检测到硬件故障时自动采取的修复操作.
undohardware-failure-detection命令用来恢复缺省情况.
【命令】hardware-failure-detection{board|chip|forwarding}{isolate|off|reset|warning}undohardware-failure-detection{board|chip|forwarding}【缺省情况】当系统检测到器件(chip)、单板(board)和转发(forwarding)的硬件故障时,修复操作均为warning.
【视图】系统视图【缺省用户角色】network-adminmdc-admin【参数】board:对单板故障进行在线检测,包括控制通道检测.
chip:对器件故障进行在线检测,包括单板上各种器件(比如芯片、电容、电阻等)的检测.
forwarding:对转发层面的故障进行在线检测,包括业务自动检测和其他转发相关的检测.
isolate:检测到故障时,设备会自动关闭端口、隔离单板、禁止单板加载或给单板下电,从而尽量减小故障的影响.
off:检测到故障时,设备不进行任何操作.
reset:检测到故障时,设备会自动重启器件/单板以尝试修复故障.
warning:检测到故障时,设备发送Trap信息,不会修复故障.
【使用指导】设备启动后,系统会持续自动检测器件、单板和转发的硬件故障.
【举例】#配置系统检测到器件故障时自动告警.
system-view[Sysname]hardware-failure-detectionchipwarning1.
1.
44hardware-failure-protectionaggregationhardware-failure-protectionaggregation命令用来开启针对聚合组的硬件故障保护功能.
undohardware-failure-protectionaggregation命令用来关闭针对聚合组的硬件故障保护功能.
【命令】hardware-failure-protectionaggregation1-50undohardware-failure-protectionaggregation【缺省情况】针对聚合组的硬件故障保护功能处于关闭状态.
【视图】系统视图【缺省用户角色】network-adminmdc-admin【使用指导】只有配置hardware-failure-detectionforwardingisolate命令后,该命令才生效.
配置该命令后,当系统检测到硬件故障时,会按顺序遵循如下原则处理:如果聚合组成员端口配置undohardware-failure-protectionauto-down命令,而且该端口不是聚合组中最后一个UP状态的端口,则该端口会被自动关闭;如果聚合组成员端口配置undohardware-failure-protectionauto-down命令,而该端口是聚合组中最后一个UP状态的端口,则该端口不会被关闭;如果聚合组成员端口配置了hardware-failure-protectionauto-down命令,则不管该端口是不是聚合组中最后一个UP状态的端口,该端口都会被关闭.
出现以下任意一种情况时,hardware-failure-protectionaggregation命令会对聚合组中的该成员端口失效:端口下配置了以太网接口环回测试功能,即loopback{external|internal}命令;端口下配置了以太网接口的强制开启功能,即portup-mode命令;该端口配置为IRF物理端口.
本命令仅缺省MDC支持.
【举例】#开启针对聚合组的硬件故障保护功能.
system-view[Sysname]hardware-failure-protectionaggregation【相关命令】hardware-failure-detectionhardware-failure-protectionauto-down1.
1.
45hardware-failure-protectionauto-downhardware-failure-protectionauto-down命令用来开启针对端口的硬件故障保护功能.
undohardware-failure-protectionauto-down命令用来关闭针对端口的硬件故障保护功能.
【命令】hardware-failure-protectionauto-downundohardware-failure-protectionauto-down1-51【缺省情况】针对端口的硬件故障保护功能处于开启状态.
【视图】以太网接口视图【缺省用户角色】network-adminmdc-admin【使用指导】在端口上配置该命令前,请确保该端口存在备份的链路,以免造成业务中断.
在端口上配置hardware-failure-protectionauto-down命令后,当系统检测到硬件故障时,会自动关闭该端口.
此时使用displayinterface命令可看到该端口状态为ProtectDOWN.
端口硬件故障解除后,请在接口下执行undoshutdown命令来恢复端口状态.
配置了hardware-failure-detectionforwardingisolate后,本命令才会生效.
出现以下任意一种情况时,hardware-failure-protectionauto-down命令会对该端口失效:端口下配置了以太网接口环回测试功能,即loopback{external|internal}命令;端口下配置了以太网接口的强制开启功能,即portup-mode命令;该端口配置为IRF物理端口.
【举例】#对端口配置硬件故障保护.
system-view[Sysname]interfaceten-gigabitethernet1/0/1[Sysname-Ten-GigabitEthernet1/0/1]hardware-failure-protectionauto-down1.
1.
46headerheader命令用来配置欢迎信息.
undoheader命令用来取消配置的欢迎信息.
【命令】header{incoming|legal|login|motd|shell}textundoheader{incoming|legal|login|motd|shell}【缺省情况】未配置欢迎信息.
【视图】系统视图【缺省用户角色】network-adminmdc-admin1-52【参数】incoming:配置Modem登录用户登录进入用户视图时的欢迎信息.
如果要求认证,则欢迎信息在通过认证后输出.
暂不支持通过Modem登录.
legal:配置登录终端界面前的授权信息,在输入认证用户名和密码前输出.
login:配置登录验证时的欢迎信息.
motd:配置登录终端界面前的欢迎信息.
shell:配置非Modem登录用户登录进入用户视图时的欢迎信息.
text:欢迎信息的内容.
内容的输入支持单行和多行两种方式,具体输入规则请参见"基础配置指导"中的"设备管理".
【举例】#配置legal欢迎信息.
system-view[Sysname]headerlegalPleaseinputbannercontent,andquitwiththecharacter'%'.
Welcometousethelegalbanner%1.
1.
47jobjob命令用来为Schedule分配Job.
undojob命令用来将Job从Schedule中删除.
【命令】jobjob-nameundojobjob-name【缺省情况】未为Schedule分配Job.
【视图】Schedule视图【缺省用户角色】network-adminmdc-admin【参数】job-name:Job的名称,为1~47个字符的字符串,区分大小写.
【使用指导】多次执行该命令,可以为Schedule分配多个Job.
多个Job在Schedule指定的时间同时执行,没有先后顺序.
分配的Job必须是设备上已经创建的Job,否则不能分配.
Job可以通过schedulerjob命令来创建.
1-53【举例】#为Schedule分配一个名称为save-job的Job.
system-view[Sysname]schedulerschedulesaveconfig[Sysname-schedule-saveconfig]jobsave-job【相关命令】schedulerjobschedulerschedule1.
1.
48memory-thresholdmemory-threshold命令用来配置空闲内存告警的门限值.
undomemory-threshold命令用来恢复缺省情况.
【命令】(独立运行模式)memory-threshold[slotslot-number[cpucpu-number]][ratio]minorminor-valueseveresevere-valuecriticalcritical-valuenormalnormal-valueundomemory-threshold[slotslot-number[cpucpu-number]](IRF模式)memory-threshold[chassischassis-numberslotslot-number[cpucpu-number]][ratio]minorminor-valueseveresevere-valuecriticalcritical-valuenormalnormal-valueundomemory-threshold[chassischassis-numberslotslot-number[cpucpu-number]]【缺省情况】一级告警门限为96MB,二级告警门限为64MB,三级告警门限为48MB,系统恢复到正常的内存门限为128MB.
【视图】系统视图【缺省用户角色】network-adminmdc-admin【参数】ratio:表示以百分比形式配置门限.
不指定该参数时,表示配置的是门限的大小,单位为MB.
minorminor-value:一级告警门限.
输入该参数的值时可通过输入,来获取该参数的取值范围.
取值为0时,表示关闭该级门限告警功能.
severesevere-value:二级告警门限.
输入该参数的值时可通过输入,来获取该参数的取值范围.
取值为0时,表示关闭该级门限告警功能.
criticalcritical-value:三级告警门限.
输入该参数的值时可通过输入,来获取该参数的取值范围.
取值为0时,表示关闭该级门限告警功能.
1-54normalnormal-value:系统内存恢复正常状态时的内存大小.
输入该参数的值时可通过输入,来获取该参数的取值范围.
slotslot-number:表示单板所在的槽位号.
不指定该参数时,表示主用主控板.
(独立运行模式)chassischassis-numberslotslot-number:表示指定成员设备上的指定单板.
chassis-number表示设备在IRF中的成员编号,slot-number表示单板所在的槽位号.
不指定该参数时,表示全局主用主控板.
(IRF模式)cpucpu-number:表示CPU编号.
【使用指导】系统实时监控系统剩余空闲内存大小,当条件达到一级、二级、三级告警门限或者恢复正常状态门限时,就产生相应的告警/告警解除通知,通知关联的业务模块/进程采取相应的措施,以便最大限度的利用内存,又能保证设备的正常运行.
关于告警门限的详细介绍请参见"基础配置指导"中的"设备管理".
【举例】#配置一级、二级、三级告警门限分别为64MB、48MB、32MB,当系统剩余空闲内存大于96MB时,恢复到正常状态.
system-view[Sysname]memory-thresholdminor64severe48critical32normal96#配置一级、二级、三级告警门限分别为设备总内存的3%、2%、1%,当系统剩余空闲内存大于设备总内存的5%时,恢复到正常状态.
system-view[Sysname]memory-thresholdratiominor3severe2critical1normal5【相关命令】displaymemory-threshold1.
1.
49memory-thresholdusagememory-thresholdusage命令用来配置内存利用率阈值.
undomemory-thresholdusage命令用来恢复缺省情况.
【命令】(独立运行模式)memory-threshold[slotslot-number[cpucpu-number]]usagememory-thresholdundomemory-threshold[slotslot-number[cpucpu-number]]usage(IRF模式)memory-threshold[chassischassis-numberslotslot-number[cpucpu-number]]usagememory-thresholdundomemory-threshold[chassischassis-numberslotslot-number[cpucpu-number]]usage【缺省情况】内存利用率阈值为100%.
1-55【视图】系统视图【缺省用户角色】network-adminmdc-admin【参数】slotslot-number:表示单板所在的槽位号,不指定该参数时,表示主用主控板.
(独立运行模式)chassischassis-numberslotslot-number:表示指定成员设备上的指定单板.
chassis-number表示设备在IRF中的成员编号,slot-number表示单板所在的槽位号.
不指定该参数时,表示全局主用主控板.
(IRF模式)cpucpu-number:表示CPU的编号.
memory-threshold:内存利用率阈值百分比,取值范围为0~100.
【使用指导】系统每隔1分钟会对内存利用率进行采样,并将采样值和用户配置的内存利用率阈值比较.
当采样值大时,则认为内存利用率过高,设备会发送Trap报文.
【举例】#配置内存利用率阈值为80%.
system-view[Sysname]memory-thresholdusage80【相关命令】displaymemory-threshold1.
1.
50monitorcpu-usageenablemonitorcpu-usageenable命令用来开启CPU利用率历史记录功能.
undomonitorcpu-usageenable命令用来关闭CPU利用率历史记录功能.
【命令】(独立运行模式)monitorcpu-usageenable[slotslot-number[cpucpu-number]]undomonitorcpu-usageenable[slotslot-number[cpucpu-number]](IRF模式)monitorcpu-usageenable[chassischassis-numberslotslot-number[cpucpu-number]]undomonitorcpu-usageenable[chassischassis-numberslotslot-number[cpucpu-number]]【缺省情况】CPU利用率历史记录功能处于开启状态.
【视图】系统视图1-56【缺省用户角色】network-adminmdc-admin【参数】slotslot-number:表示单板所在的槽位号,不指定表示主用主控板.
(独立运行模式)chassischassis-numberslotslot-number:表示指定成员设备上的指定单板.
chassis-number表示设备在IRF中的成员编号,slot-number表示单板所在的槽位号.
不指定该参数时,表示全局主用主控板.
(IRF模式)cpucpu-number:表示CPU的编号.
【使用指导】开启CPU利用率历史记录功能后,系统会每隔一定时间(可通过monitorcpu-usageinterval命令配置)对CPU的利用率进行采样,并把采样结果保存到历史记录区.
这些记录可通过displaycpu-usagehistory命令查看,以便用户监控设备近期的运行情况.
【举例】#打开CPU利用率历史记录功能.
system-view[Sysname]monitorcpu-usageenable【相关命令】displaycpu-usageconfigurationdisplaycpu-usagehistorymonitorcpu-usageinterval1.
1.
51monitorcpu-usageintervalmonitorcpu-usageinterval命令用来配置CPU利用率历史记录的采样周期.
【命令】(独立运行模式)monitorcpu-usageintervalinterval[slotslot-number[cpucpu-number]](IRF模式)monitorcpu-usageintervalinterval[chassischassis-numberslotslot-number[cpucpu-number]]【缺省情况】CPU利用率历史记录采样周期为1分钟.
【视图】系统视图【缺省用户角色】network-adminmdc-admin1-57【参数】interval:CPU利用率历史记录采用周期,取值为5Sec、1Min或者5Min,不区分大小写.
输入该参数时,请完整输入,否则,系统会提示参数错误.
slotslot-number:表示单板所在的槽位号.
不指定该参数时,表示主用主控板.
(独立运行模式)chassischassis-numberslotslot-number:表示指定成员设备上的指定单板.
chassis-number表示设备在IRF中的成员编号,slot-number表示单板所在的槽位号.
不指定该参数时,表示全局主用主控板.
(IRF模式)cpucpu-number:表示CPU的编号.
【使用指导】开启CPU利用率历史记录功能后,系统会每隔一定时间(可通过monitorcpu-usageinterval命令配置)对CPU的利用率进行采样,并把采样结果保存到历史记录区.
这些记录可通过displaycpu-usagehistory命令查看,以便用户监控设备近期的运行情况.
【举例】#配置CPU利用率历史记录的采样周期为5秒.
system-view[Sysname]monitorcpu-usageinterval5Sec【相关命令】displaycpu-usageconfigurationdisplaycpu-usagehistorymonitorcpu-usageenable1.
1.
52monitorcpu-usagethresholdmonitorcpu-usagethreshold命令用来配置CPU利用率阈值.
undomonitorcpu-usagethreshold命令用来恢复缺省情况.
【命令】(独立运行模式)monitorcpu-usagethresholdcpu-threshold[slotslot-number[cpucpu-number]]undomonitorcpu-usagethreshold[slotslot-number[cpucpu-number]](IRF模式)monitorcpu-usagethresholdcpu-threshold[chassischassis-numberslotslot-number[cpucpu-number]]undomonitorcpu-usagethreshold[chassischassis-numberslotslot-number[cpucpu-number]]【缺省情况】CPU利用率阈值为99%.
【视图】系统视图1-58【缺省用户角色】network-adminmdc-admin【参数】cpu-threshold:CPU利用率阈值百分比,取值范围为0~100.
slotslot-number:表示单板所在的槽位号.
不指定该参数时,表示主用主控板.
(独立运行模式)chassischassis-numberslotslot-number:表示指定成员设备上的指定单板.
chassis-number表示设备在IRF中的成员编号,slot-number表示单板所在的槽位号.
不指定该参数时,表示全局主用主控板.
(IRF模式)cpucpu-number:表示CPU的编号.
【使用指导】系统每隔1分钟会对CPU的利用率进行采样,并将采样值和用户配置的CPU利用率阈值比较.
当采样值大时,则认为CPU利用率过高,设备会发送Trap报文.
【举例】#配置CPU利用率阈值为80%.
system-view[Sysname]monitorcpu-usagethreshold80【相关命令】displaycpu-usageconfiguration1.
1.
53monitorhandshake-timeoutdisable-portmonitorhandshake-timeoutdisable-port命令用于全局开启PortDown功能.
undomonitorhandshake-timeoutdisable-port命令用于全局关闭PortDown功能.
【命令】monitorhandshake-timeoutdisable-portundomonitorhandshake-timeoutdisable-port【缺省情况】缺省情况下,PortDown功能处于开启状态.
【视图】系统视图【缺省用户角色】network-adminmdc-admin【描述】本功能常用于以主备方式提供网络可靠性的双机环境中(例如VRRP).
开启本功能后,当主设备的主控板被拔出或异常重启时,系统将立即关闭主设备上的所有业务口,使业务快速切换到备用设备上.
1-59该功能配置成功后,只有当当前设备上已没有可用的主控板时才生效.
【举例】#全局开启PortDown功能.
system-viewSystemView:returntoUserViewwithCtrl+Z.
[Sysname]monitorhandshake-timeoutdisable-portSetsuccessful!
1.
1.
54password-recoveryenablepassword-recoveryenable命令用来开启密码恢复功能.
undopassword-recoveryenable命令用来关闭密码恢复功能.
【命令】password-recoveryenableundopassword-recoveryenable【缺省情况】密码恢复功能处于开启状态.
【视图】系统视图【缺省用户角色】network-adminmdc-admin【使用指导】配置密码恢复功能后,当用户忘记Console口认证密码或者登录认证失败,导致无法使用命令行操作设备时,可通过BootWare菜单清除该认证密码,再继续使用设备;关闭密码恢复功能后,设备将处于一个安全性更高的状态,即当出现上述情况时,若想继续使用Console口对设备进行命令行操作,只能通过BootWare菜单选择将设备恢复为出厂配置之后方可继续操作,这样可以有效地防止非法用户获取启动配置文件.
BootWare菜单中支持配置的选项与密码恢复功能的配置有关,详见"基础配置指导"中的"BootWare管理配置".
【举例】#关闭密码恢复功能.
system-view[Sysname]undopassword-recoveryenable1-601.
1.
55rebootreboot命令用来重启设备.
【命令】(独立运行模式)reboot[slotslot-number][force](IRF模式)reboot[chassischassis-number[slotslot-number]][force]【视图】用户视图【缺省用户角色】network-adminmdc-admin【参数】chassischassis-number:表示设备在IRF中的成员编号.
(IRF模式)slotslot-number:表示单板所在的槽位号.
force:强制重启:不指定该参数时,重启设备,系统会做一些保护性检查(如启动文件是否存在,是否正在写磁盘等),若检查不通过则退出处理,不会重启设备;指定该参数时,系统将不进行任何检查,直接执行重启操作.
【使用指导】重新启动可能会导致业务中断,请谨慎使用该命令.
使用force参数时,系统在重启时不会做任何保护性措施.
重启后,可能导致文件系统损坏,请谨慎使用该参数.
建议在系统故障或无法正常重启时,才使用该参数.
如果主用启动文件损坏或者不存在,则不能通过reboot命令重启设备.
此时,可以通过指定新的主用启动文件再重启.
如果设备在准备重启时,用户正在进行文件操作,为了安全起见,系统将不会执行此次重启操作.
(独立运行模式)不指定slot参数,会重启整个设备.
指定slot参数,会重启指定单板.
重启主用主控板时,如果备用主控板不存在,会重启整个系统;如果备用主控板存在并稳定运行,会引起主备倒换.
当系统中有单板处于非稳定状态时,请不要使用reboot命令来触发主备倒换,以免影响系统和单板的运行.
可使用displaysystemstablestate命令来显示系统的稳定状态.
(IRF模式)不指定chassis和slot参数,则会重启所有成员设备.
1-61只指定chassis不指定slot参数,则会重启IRF中指定的成员设备.
同时指定chassis和slot参数,则会重启IRF中指定的单板.
重启全局主用主控板时,如果全局备用主控板不存在,会重启整个IRF;如果全局备用主控板存在并稳定运行,会引起主备倒换.
当系统中有单板处于非稳定状态时,请不要使用reboot命令来触发主备倒换,以免影响IRF和单板的运行.
可使用displaysystemstablestate命令来显示IRF的稳定状态.
【举例】#重启设备,并保存配置文件.
rebootStarttocheckconfigurationwithnextstartupconfigurationfile,pleasewait.
DONE!
Currentconfigurationwillbelostafterthereboot,savecurrentconfiguration[Y/N]:yPleaseinputthefilename(*.
cfg)[flash:/startup.
cfg](Toleavetheexistingfilenameunchanged,presstheenterkey):flash:/startup.
cfgexists,overwrite[Y/N]:yValidatingfile.
Pleasewait.
.
.
Configurationissavedtoflashsuccessfully.
Thiscommandwillrebootthedevice.
Continue[Y/N]:yNowrebooting,pleasewait.
.
.
#强制重启设备.
rebootforceAforcedrebootmightcausethestoragemediumtobecorrupted.
Continue[Y/N]:yNowrebooting,pleasewait.
.
.
【相关命令】displaysystemstablestate1.
1.
56resetasset-inforesetasset-info命令用来清除设备的用户资产信息.
使用该命令,用户可以清除设备机箱、单板、风扇框或电源模块的资产信息.
【命令】(独立运行模式)resetasset-info{chassis|fanfan-id|powerpower-id|slotslot-number}{csn|custom|department|description|location|service-date|state}(IRF模式)resetasset-infochassischassis-number{chassis|fanfan-id|powerpower-id|slotslot-number}{csn|custom|department|description|location|service-date|state}【视图】系统视图【缺省用户角色】network-adminnetwork-operator1-62mdc-adminmdc-operator【参数】chassis:清除设备机箱的用户资产信息.
设备不支持配置本参数.
fanfan-id:清除指定风扇框的用户资产信息.
fan-id表示设备上风扇框的编号.
设备不支持配置本参数.
powerpower-id:清除指定电源模块的用户资产信息.
power-id表示设备上电源模块的编号.
设备不支持配置本参数.
slotslot-number:清除指定单板的用户资产信息.
slot-number表示设备上单板所在的槽位号.
csn:清除资产编号信息.
custom:清除用户自定义的资产信息.
department:清除资产的归属部门信息.
description:清除资产的描述信息.
location:清除资产的位置信息.
service-date:清除资产的启用时间信息.
state:清除资产的使用状态信息.
chassischassis-number:清除指定成员设备的用户资产信息.
chassis-number表示设备在IRF中的成员编号.
(IRF模式)【描述】resetasset-info命令用来清除设备的用户资产信息.
使用该命令,用户可以清除单板的资产信息.
当用户希望清除单板的具体信息项目(比如资产编号、资产描述信息等)时,只需要选择该信息项目对应的命令行参数;不选择具体信息项目对应的参数时,清除的是该单板的所有用户资产信息.
【举例】#清除设备上0号单板的资产编号信息.
(独立运行模式)system-view[Sysname]resetasset-infoslot0csn【相关命令】displayasset-infosetasset-info1.
1.
57resetschedulerlogfileresetschedulerlogfile命令用来清除Schedule日志文件的相关信息.
【命令】resetschedulerlogfile【视图】用户视图1-63【缺省用户角色】network-adminmdc-admin【举例】#清除Schedule日志文件的相关信息.
resetschedulerlogfile【相关命令】displayschedulerlogfile1.
1.
58resetversion-update-recordresetversion-update-record命令用来清除启动软件包版本更新操作的记录.
【命令】resetversion-update-record【视图】系统视图【缺省用户角色】network-adminmdc-admin【举例】#清除设备启动软件包版本更新操作的记录.
system-view[Sysname]resetversion-update-recordThiscommandwilldeleteallrecordsofversionupdate.
Continue[Y/N]:y【相关命令】displayversion-update-record1.
1.
59restorefactory-defaultrestorefactory-default命令用来将设备恢复到出厂状态.
【命令】restorefactory-default【视图】用户视图【缺省用户角色】network-adminmdc-admin1-64【使用指导】请谨慎使用该命令.
当设备使用场景更改,或者设备出现故障时,可以使用本命令来将设备恢复到出厂状态.
【举例】#将设备恢复到出厂状态.
restorefactory-defaultThiscommandwillrestorethesystemtothefactorydefaultconfigurationandcleartheoperationdata.
Continue[Y/N]:yRestoringthefactorydefaultconfiguration.
Thisprocessmighttakeafewminutes.
Pleasewait.
Done.
Pleaserebootthesystemtoplacethefactorydefaultconfigurationintoeffect.
【相关命令】reboot1.
1.
60schedulerjobschedulerjob命令用来创建Job,并进入Job视图.
如果指定的Job已存在,则直接进入Job视图.
undoschedulerjob命令用来删除已创建的Job.
【命令】schedulerjobjob-nameundoschedulerjobjob-name【缺省情况】不存在Job.
【视图】系统视图【缺省级别】network-adminmdc-admin【参数】job-name:Job的名称,为1~47个字符的字符串,区分大小写.
【使用指导】一个Job可以被多个Schedule引用.
Job视图下用户可以通过command命令为Job分配命令.
【举例】#创建名称为backupconfig的Job并进入Job视图.
system-view[Sysname]schedulerjobbackupconfig[Sysname-job-backupconfig]1-65【相关命令】commandschedulerschedule1.
1.
61schedulerlogfilesizeschedulerlogfilesize命令用来配置Schedule日志文件的大小.
【命令】schedulerlogfilesizevalue【缺省情况】Schedule日志文件的大小为16KB.
【视图】系统视图【缺省用户角色】network-adminmdc-admin【参数】value:Schedule日志文件的大小,取值范围为16~1024,单位是KB.
【使用指导】Schedule日志文件用来记录Job下命令行的执行结果.
如果该文件的大小超过了用户配置值,则系统会把老的记录删除,用来记录新的记录.
如果要记录的日志信息超长,超过了日志文件的大小,则该日志超出的部分不会记录.
【举例】#配置Schedule日志文件的大小为32KB.
system-view[Sysname]schedulerlogfilesize32【相关命令】displayschedulerlogfile1.
1.
62schedulerrebootatschedulerrebootat命令用来配置设备重启的具体时间和日期.
undoschedulerreboot命令用来取消定时重启配置.
【命令】schedulerrebootattime[date]undoschedulerreboot【缺省情况】未配置设备重启的具体时间和日期.
1-66【视图】用户视图【缺省用户角色】network-adminmdc-admin【参数】time:设备重启的时间,格式为HH:MM.
HH代表小时,取值范围为0~23,MM代表分钟,取值范围为0~59.
date:设备重启的日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日).
YYYY的取值范围为2000~2035;MM的取值范围为1~12;DD的取值范围与具体月份有关.
【使用指导】该命令会使设备在将来的某个时间点重新启动,从而导致业务中断,请谨慎使用.
如果没有指定date参数,并且:配置的时间点在当前时间之后,则设备将在当天的该时间点重启;配置的时间点在当前时间之前,则设备将在第二天的该时间点重启.
多次配置schedulerrebootat、schedulerrebootdelay命令,最后一次执行的命令生效.
如果设备在准备重启时,用户正在进行文件操作,为了安全起见,系统将不会执行此次重启操作.
【举例】#假设系统的当前时间为2015年6月6日11:43,配置设备在当天中午12:00重启.
schedulerrebootat12:00Rebootsystemat12:00:0006/06/2015(in0hoursand16minutes).
Confirm[Y/N]:【相关命令】schedulerrebootdelay1.
1.
63schedulerrebootdelayschedulerrebootdelay命令用来配置重启设备的延迟时间.
undoschedulerreboot命令用来取消定时重启配置.
【命令】schedulerrebootdelaytimeundoschedulerreboot【缺省情况】未配置重启设备的延迟时间.
【视图】用户视图1-67【缺省用户角色】network-adminmdc-admin【参数】time:设备重启的等待时延,格式为HH:MM(小时:分钟)或MM(分钟).
使用HH:MM格式时,MM的取值范围为0~59,HH:MM的最大长度为6个字符.
使用MM格式时,最大长度为6个字符.
【使用指导】该命令会使设备在将来的某个时间点重新启动,从而导致业务中断,请谨慎使用.
多次配置schedulerrebootat、schedulerrebootdelay命令,最后一次执行的命令生效.
如果设备在准备重启时,用户正在进行文件操作,为了安全起见,系统将不会执行此次重启操作.
【举例】#假设系统的当前时间为2015年6月6日11:48,配置设备在88分钟后重启.
schedulerrebootdelay88Rebootsystemat13:1606/06/2015(in1hoursand28minutes).
Confirm[Y/N]:1.
1.
64schedulerscheduleschedulerschedule命令用来创建Schedule,并进入相应的Schedule视图.
如果指定的Schedule已存在,则直接进入Schedule视图.
undoschedulerschedule命令用来删除指定Schedule.
【命令】schedulerscheduleschedule-nameundoschedulerscheduleschedule-name【缺省情况】不存在Schedule.
【视图】系统视图【缺省用户角色】network-adminmdc-admin【参数】schedule-name:Schedule的名称,为1~47个字符的字符串,区分大小写.
【使用指导】使用schedulerschedule命令可以配置定时执行任务,让设备在指定时间执行指定命令.
配置步骤如下:(1)使用schedulerjob命令创建Job.
1-68(2)在Job视图下,使用command命令配置需要执行的命令.
(3)使用schedulerschedule命令创建Schedule.
(4)在Schedule视图下,使用job命令为Schedule分配Job.
一个Schedule下可以分配多个Job,但必须是已创建的Job,否则分配失败.
(5)在Schedule视图下,使用user-role命令为Schedule配置用户角色.
一个Schedule下最多可以分配64个角色.
(6)在Schedule视图下,使用timeat、timeonce或者timerepeating命令来配置任务执行的时间.
一个Schedule下只能配置一个执行时间.
【举例】#创建名为saveconfig的Schedule.
system-view[Sysname]schedulerschedulesaveconfig【相关命令】jobtimeattimeonce1.
1.
65setasset-infosetasset-info命令用来设置设备的用户资产信息.
使用该命令,用户可以根据自定义的规则为设备机箱、单板、风扇框及电源模块设置资产信息.
【命令】(独立运行模式)setasset-info{chassis|fanfan-id|powerpower-id|slotslot-number}{csncsn-number|customnamevalue|departmentdepartment|descriptiondescription|locationlocation|service-datedate|statestate}(IRF模式)setasset-infochassischassis-number{chassis|fanfan-id|powerpower-id|slotslot-number}{csncsn-number|customnamevalue|departmentdepartment|descriptiondescription|locationlocation|service-datedate|statestate}【视图】系统视图【缺省用户角色】network-adminnetwork-operatormdc-adminmdc-operator【参数】chassis:设置设备机箱的用户资产信息.
设备不支持配置本参数.
1-69fanfan-id:设置指定风扇框的用户资产信息.
fan-id表示设备上风扇框的编号.
设备不支持配置本参数.
powerpower-id:设置指定电源模块的用户资产信息.
power-id表示设备上电源模块的编号.
设备不支持配置本参数.
slotslot-number:设置指定单板的用户资产信息.
slot-number表示设备上单板所在的槽位号.
csncsn-number:设置资产编号信息.
csn-number表示用户设置的资产编号信息,为1~64字节的字符串.
customnamevalue:设置用户自定义的资产信息.
name表示用户自定义的资产信息名称,value表示用户设置的资产信息内容.
departmentdepartment:设置资产的归属部门信息.
department表示用户设置的资产归属部门,为1~64字节的字符串.
descriptiondescription:设置资产的描述信息.
description表示用户设置的资产描述信息,为1~64字节的字符串.
locationlocation:设置资产的位置信息.
location表示用户设置的资产位置信息,为1~64字节的字符串.
service-datedate:设置资产的启用时间信息.
date表示用户设置的资产启用时间,为1~25字节的字符串.
statestate:设置资产的使用状态信息.
state表示用户设置的资产使用状态,为1~64字节的字符串.
chassischassis-number:设置指定成员设备的用户资产信息.
chassis-number表示设备在IRF中的成员编号.
(IRF模式)【举例】#设置设备上0号单板的资产编号为123456.
(独立运行模式)system-view[Sysname]setasset-infoslot0csn123456【相关命令】displayasset-inforesetasset-info产品特有举例-setserial-no1.
1.
66shutdown-intervalshutdown-interval命令用来配置端口状态检测定时器的时长.
undoshutdown-interval命令用来恢复缺省情况.
【命令】shutdown-intervalintervalundoshutdown-interval【缺省情况】端口状态检测定时器的时长为30秒.
1-70【视图】系统视图【缺省用户角色】network-adminmdc-admin【参数】interval:端口状态检测定时器的时长,取值范围为0~300,单位为秒.
取值为0时,表示不进行定时检测.
【使用指导】某些协议模块在特定情况下会自动关闭某个端口,比如当开启了BPDU保护功能的端口收到配置消息时,MSTP协议模块将自动关闭该端口.
同时,系统会启动一个检测定时器,如果直到定时器超时(即经过time秒之后),该端口仍处于关闭状态,协议模块则自动激活该端口,令其恢复到真实的物理状态.
如果用户在端口定时检测过程中将检测时间间隔修改为T1,修改时刻距协议关闭端口时间间隔为T.
若T=T1,则被关闭的端口会立即恢复.
例如当前time配置为30,当端口被协议模块关闭2秒(T=2)后,修改time为10(T1=10),则该接口会再经过8秒后被恢复;如果当前time为30,端口被协议模块关闭10秒后,修改time为2,则该端口会立即恢复.
【举例】#配置端口状态检测定时器的时长为100秒.
system-view[Sysname]shutdown-interval1001.
1.
67switch-modeswitch-mode命令用于配置交换机单板工作模式和代理模式.
undoswitch-mode命令用于恢复单板工作模式和代理模式为未配置状态.
【命令】(独立运行模式)switch-mode{balance|bridging|enhance-bridging|ipv6|routing|mix-bridging-routing|normal|standard-ipv6}[adj-proxy-high|adj-proxy-low|l3-proxy-high|route-proxy-high|route-proxy-low]slotslot-numberundoswitch-modeslotslot-number(IRF模式)switch-mode{balance|bridging|enhance-bridging|ipv6|routing|mix-bridging-routing|normal|standard-ipv6}[adj-proxy-high|adj-proxy-low|l3-proxy-high|route-proxy-high|route-proxy-low]chassischassis-numberslotslot-number1-71undoswitch-modechassischassis-numberslotslot-number【缺省情况】单板工作模式的缺省情况请参见"基础配置指导"中的"设备管理".
单板的缺省代理模式为未配置状态,即既不作为代理单板也不作为被代理单板.
【视图】系统视图【缺省用户角色】network-adminmdc-admin【参数】balance:单板工作模式为均衡模式.
ipv6:单板工作模式为IPv6模式.
bridging:单板工作模式为MAC扩展模式.
enhance-bridging:单板工作模式为增强的MAC扩展模式.
normal:单板工作模式为普通模式.
routing:单板工作模式为路由扩展模式.
mix-bridging-routing:单板工作模式为混合扩展模式.
standard-ipv6:单板工作模式为IPv6标准模式.
route-proxy-high:单板的代理模式为路由代理模式.
route-proxy-low:单板的代理模式为路由被代理模式.
adj-prxoy-high:单板的代理模式为ARP/ND代理模式.
adj-proxy-low:单板的代理模式为ARP/ND被代理模式.
l3-proxy-high:单板的代理模式为路由/ARP/ND代理模式.
slotslot-number:单板所在槽位号.
chassischassis-number:表示IRF中设备的成员编号.
(IRF模式)【使用指导】单板工作模式和代理模式配置完毕后需保存配置并重启该单板,所做配置才会生效.
单板工作模式和代理模式支持情况请参见"基础配置指导"中的"设备管理".
当单板的路由、ARP或ND表项大小不够,无法满足需求时,可配置单板的单板代理模式.
单板代理模式是在本设备上将路由、ARP或ND表项较小的单板作为被代理单板,路由、ARP或ND表项较大的单板作为代理单板.
当配置成ARP/ND或路由代理模式后,被代理单板上收到需要转发的流量时,会将这些流量重定向到代理单板,在代理单板上查找转发表项,进行转发.
当配置单板路由代理/被代理模式时,需要注意的是:请确保同一台设备上至少各有一块单板被配置成被代理单板或代理单板,否则可能导致代理功能不生效.
例如,一台设备上有一块单板配置成route-proxy-low模式后,必须有一块单板配置成route-proxy-high或l3-proxy-high模式.
1-72请不要在配置为单板路由被代理模式的单板上终结隧道报文和MPLS报文.
隧道和MPLS的详细介绍,请分别参见"三层技术-IP业务配置指导"中的"隧道"和"MPLS配置指导"中的"MPLS基础".
对于配置了route-proxy-low模式的单板,如果应用的策略路由中有applydefault-next-hop命令,那么,applydefault-next-hop命令将不生效.
有关策略路由的详细介绍,请参见"三层技术-IP路由配置指导"中的"策略路由".
配置了route-proxy-low模式的单板的路由接口不支持转发VPN报文.
VPN的详细介绍,请参见"MPLS配置指导"中的"MPLSL3VPN".
对于组播报文,代理模式配置后不生效.
组播的详细介绍,请参见"IP组播配置指导"中的"组播路由与转发".
对于FD系列接口板、FE系列接口板和SG系列接口板,配置route-proxy-low模式后,不支持转发VXLAN网络的三层流量.
VXLAN的详细介绍,请参见"VXLAN配置指导".
当配置单板工作模式时,需要注意的是:当交换机中存在多块SD或EB系列接口板时,建议配置一致的工作模式.
对SD或EB系列接口板进行初次模式切换或者模式切换后初次升级软件版本时,接口板可能会因为系统优化自动重启1~2次,需要6~10分钟.
【举例】#配置设备2号槽位单板的工作模式为IPv6标准模式(standard-ipv6).
(独立运行模式)system-view[Sysname]switch-modestandard-ipv6slot2#配置设备2号槽位单板的工作模式为MAC扩展模式(bridging),单板的代理模式为路由被代理模式(route-proxy-low).
(独立运行模式)system-view[Sysname]swtich-modebridgingroute-proxy-lowslot2【相关命令】displayswitch-modestatus1.
1.
68sysnamesysname命令用来配置设备的名称.
undosysname用来恢复缺省情况.
【命令】sysnamesysnameundosysname【缺省情况】设备的名称为H3C.
【视图】系统视图【缺省用户角色】network-admin1-73mdc-admin【参数】sysname:设备名称,为1~64个字符的字符串.
【使用指导】设备的名称对应于命令行接口的提示符,如设备的名称为Sysname,则用户视图的提示符为.
【举例】#配置设备的名称为R2000.
system-view[Sysname]sysnameR2000[R2000]1.
1.
69system-working-modesystem-working-mode命令用来配置设备的工作模式.
undosystem-working-mode命令用来恢复缺省情况.
【命令】system-working-mode{advance|standard}undosystem-working-mode【缺省情况】设备工作在标准模式.
【视图】系统视图【缺省用户角色】network-adminmdc-admin【参数】advance:将设备的工作模式配置为高级模式.
standard:将设备的工作模式配置为标准模式.
【使用指导】不同模式下设备支持的特性不同,或者相同的特性支持的规格不同,详细描述请参见"基础配置指导"中的"设备管理".
要使修改的工作模式生效,必须重启设备.
【举例】#将设备工作模式配置为高级模式.
system-view[Sysname]system-working-modeadvanceDoyouwanttochangethesystemworkingmode[Y/N]:y1-74Systemworkingmodechanged.
Forthechangetotakeeffect,savetherunningconfigurationandrebootthedevice.
1.
1.
70temperature-limittemperature-limit命令用于配置设备的温度告警门限.
undotemperature-limit命令用来恢复缺省情况.
【命令】(独立运行模式)temperature-limitslotslot-number{hotspot|inflow|outflow}sensor-numberlowlimitwarninglimit[alarmlimit]undotemperature-limitslotslot-number{hotspot|inflow|outflow}sensor-number(IRF模式)temperature-limitchassischassis-numberslotslot-number{hotspot|inflow|outflow}sensor-numberlowlimitwarninglimit[alarmlimit]undotemperature-limitchassischassis-numberslotslot-number{hotspot|inflow|outflow}sensor-number【缺省情况】不同温度传感器的温度门限可能不同,请先使用undotemperature-limit命令恢复缺省情况后,再通过displayenvironment命令查看设备的缺省温度告警门限.
【视图】系统视图【缺省用户角色】network-adminmdc-admin【参数】chassischassis-number:表示设备在IRF中的成员编号.
(IRF模式)slotslot-number:配置指定单板上温度传感器的温度门限.
slot-number表示单板所在的槽位号.
hotspot:配置热点传感器的温度门限.
热点传感器一般置于发热量较大的芯片附近,监测芯片温度.
inflow:配置入风传感器的温度门限.
入风传感器一般置于入风口附近,监测环境温度.
outflow:配置出风传感器的温度门限.
出风传感器一般置于出风口附近,监测设备温度.
sensor-number:温度传感器的编号,输入该参数的值时可通过输入,来获取该参数的取值范围.
lowlimit:低温告警门限,单位为摄氏度.
不同温度传感器的低温告警门限取值范围不同,输入该参数的值时可通过输入,来获取该参数的取值范围.
warninglimit:一般级高温告警门限,单位为摄氏度,必须大于低温告警门限.
输入该参数的值时可通过输入,来获取该参数的取值范围.
alarmlimit:严重级高温告警门限,单位为摄氏度,必须大于一般级高温告警门限.
输入该参数的值时可通过输入,来获取该参数的取值范围.
1-75【使用指导】如果温度低于低温告警门限、高于一般级或严重级高温门限,系统均会生成相应的日志信息和告警信息提示用户,并通过设备面板上的指示灯来告警,以便用户及时进行处理.
本命令仅缺省MDC支持.
【举例】#配置指定slot上热点1号温度传感器,低温门限为-10摄氏度,一般级高温门限为50摄氏度,严重级高温门限为60摄氏度.
(独立运行模式)system-view[sysname]temperature-limitslot1hotspot1-105060【相关命令】displayenvironment1.
1.
71timeattimeat命令用来配置在指定时刻执行Schedule.
undotime命令用来为Schedule取消执行时间配置.
【命令】timeattimedateundotime【缺省情况】未为Schedule配置执行时间.
【视图】Schedule视图【缺省用户角色】network-adminmdc-admin【参数】time:Schedule的执行时间,格式为HH:MM(小时:分钟).
HH取值范围为0~23,MM取值范围为0~59.
date:Schedule执行的日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日).
YYYY的取值范围为2000~2035;MM的取值范围为1~12;DD的取值范围与具体月份有关.
【使用指导】配置的时间点必须晚于系统当前时间点,否则配置失败.
一个Schedule只能配置一个执行时间.
因此,同一Schedule视图下,多次执行timeat、timeonce或timerepeating命令时,最后一次执行的命令生效.
1-76【举例】#配置2015年5月11日1点1分执行名称为saveconfig的Schedule.
system-view[Sysname]schedulerschedulesaveconfig[Sysname-schedule-saveconfig]timeat1:12015/05/11【相关命令】schedulerschedule1.
1.
72timeoncetimeonce命令用来为Schedule配置执行时间.
undotime命令用来为Schedule取消执行时间配置.
【命令】timeonceattime[month-datemonth-day|week-dayweek-day&]timeoncedelaytimeundotime【缺省情况】未为Schedule配置执行时间.
【视图】Schedule视图【缺省用户角色】network-adminmdc-admin【参数】attime:Schedule的执行时间,格式为HH:MM(小时:分钟).
HH取值范围为0~23,MM取值范围为0~59.
month-datemonth-day:Schedule在一个月中的哪天被执行.
month-day表示日期,取值范围为1~31.
如果指定了一个本月不存在的日期,则实际生效的时间为下一个月的该日期,比如,二月没有30号,则实际生效的时间为三月的30号.
week-dayweek-day&:Schedule在一周中的哪(些)天被执行.
week-day&表示一周中任一天或几天的组合,week-day取值为:Mon、Tue、Wed、Thu、Fri、Sat、Sun,&表示前面的参数最多可以输入7次.
配置多天时,字符串之间用空格分开.
delaytime:指定Schedule延迟执行的时间.
格式为HH:MM(小时:分钟)或MM(分钟).
使用HH:MM格式时,MM的取值范围为0~59,HH:MM最大长度为6个字符.
使用MM格式时,最大长度为6个字符.
【使用指导】配置该命令后,Schedule在该设定时间点到达时执行,若当天/本月/本周该时间点已过去,则顺延到第二天/下月/下周.
执行后下次再到达该时间点时Schedule不再执行.
1-77一个Schedule只能配置一个执行时间.
因此,同一Schedule视图下,多次执行timeat、timeonce或timerepeating命令时,最后一次执行的命令生效.
【举例】#当天的15点执行名称为saveconfig的Schedule.
system-view[Sysname]schedulerschedulesaveconfig[Sysname-schedule-saveconfig]timeonceat15:00#最近到达的15号的15点执行名称为saveconfig的Schedule.
system-view[Sysname]schedulerschedulesaveconfig[Sysname-schedule-saveconfig]timeonceat15:00month-date15#最近一个周一和周五的12点整执行名称为saveconfig的Schedule.
system-view[Sysname]schedulerschedulesaveconfig[Sysname-schedule-saveconfig]timeonceat12:00week-daymonfri#延迟10分钟执行名称为saveconfig的Schedule.
system-view[Sysname]schedulerschedulesaveconfig[Sysname-schedule-saveconfig]timeoncedelay10【相关命令】schedulerschedule1.
1.
73timerepeatingtimerepeating命令用来配置重复执行Schedule的时间.
undotime命令用来为Schedule取消执行时间配置.
【命令】timerepeating[attime[date]]intervalintervaltimerepeatingattime[month-date[month-day|last]|week-dayweek-day&]undotime【缺省情况】未配置重复执行Schedule的时间.
【视图】Schedule视图【缺省用户角色】network-adminmdc-admin【参数】attime:表示重复执行的时间,格式为HH:MM(小时:分钟).
HH取值范围为0~23,MM取值范围为0~59.
不指定该参数时,表示从现在开始.
1-78date:指定Schedule重复执行的开始日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日).
不指定该参数时,表示将来第一次到达time的时间点的日期.
YYYY的取值范围为2000~2035;MM的取值范围为1~12;DD的取值范围与具体月份有关.
intervalinterval:指定重复执行的时间间隔.
格式为HH:MM(小时:分钟)或MM(分钟).
使用HH:MM格式时,MM的取值范围为0~59,最大长度为6个字符.
使用MM格式时,取值的最小值为1,最大长度为6个字符.
month-date[month-day|last]:表示每月中的某一天.
其中,month-day表示日期,取值范围为1~31.
如果指定了一个本月不存在的日期,则实际生效的时间为下一个月的该日期,比如,二月没有30号,则实际生效的时间为三月的30号.
last表示每月的最后一天.
week-dayweek-day&:表示每周中的某(些)天.
week-day&表示一周中任一天或几天的组合,week-day取值为:Mon、Tue、Wed、Thu、Fri、Sat、Sun,&表示前面的参数最多可以输入7次.
配置多天时,字符串之间用空格分开.
【使用指导】timerepeating[attime[date]]intervalinterval表示从指定时间开始,周期性执行Schedule.
timerepeatingattime[month-date[month-day|last]|week-dayweek-day&]表示每月/每周的某(些)天重复执行Schedule.
一个Schedule只能配置一个执行时间.
因此,同一Schedule视图下,多次执行timeat、timeonce或timerepeating命令时,最后一次执行的命令生效.
【举例】#配置从早上八点开始,每隔1小时执行一次名称为saveconfig的Schedule.
system-view[Sysname]schedulerschedulesaveconfig[Sysname-schedule-saveconfig]timerepeatingat8:00interval60#配置从现在开始每天的12:00执行名称为saveconfig的Schedule.
system-view[Sysname]schedulerschedulesaveconfig[Sysname-schedule-saveconfig]timerepeatingat12:00#配置从现在开始每个月5号的上午8点执行名称为saveconfig的Schedule.
system-view[Sysname]schedulerschedulesaveconfig[Sysname-schedule-saveconfig]timerepeatingat8:00month-date5#配置从现在开始每个月的最后一天8点执行名称为saveconfig的Schedule.
system-view[Sysname]schedulerschedulesaveconfig[Sysname-schedule-saveconfig]timerepeatingat8:00month-datelast#配置从现在开始每个周五和周六的上午8点执行名称为saveconfig的Schedule.
system-view[Sysname]schedulerschedulesaveconfig[Sysname-schedule-saveconfig]timerepeatingat8:00week-dayfrisat1-79【相关命令】schedulerschedule1.
1.
74transceiverphony-alarm-disabletransceiverphony-alarm-disable命令用来关闭可插拔接口模块告警信息开关.
undotransceiverphony-alarm-disable命令用来恢复缺省情况.
【命令】transceiverphony-alarm-disableundotransceiverphony-alarm-disable【缺省情况】可插拔接口模块告警信息开关处于开启状态.
【视图】系统视图【缺省用户角色】network-adminmdc-admin【使用指导】设备根据光模块中记录的厂商信息来判断对应接口上插入的光模块的厂商是不是H3C.
如果不是H3C,则会输出Trap和Log信息提醒用户,要求用户更换成H3C的光模块,以便管理和维护光模块.
用户可使用displaytransceivermanuinfo命令查看光模块的厂商信息.
而H3C早期销售的光模块,可能没有记录厂商信息,为了保护用户投资,这样的光模块还能继续正常使用,但仍会输出Trap和Log信息.
此时,可使用本命令,停止输出相关信息.
【举例】#关闭可插拔接口模块告警信息开关.
system-view[Sysname]transceiverphony-alarm-disable【相关命令】displaytransceivermanuinfo1.
1.
75user-roleuser-role命令用来配置执行Schedule时使用的用户角色.
undouser-role命令用来将已经配置的用户角色从Schedule中删除.
【命令】user-rolerole-nameundouser-rolerole-name【缺省情况】执行Schedule时使用的用户角色,为创建该Schedule的用户的用户角色.
1-80【视图】Schedule视图【缺省用户角色】network-adminmdc-admin【参数】role-name:用户角色的名称,为1~63个字符的字符串,区分大小写.
可以是系统预定义的角色名称,包括network-admin、network-operator、mdc-admin、mdc-operator、level-0~level-15,也可以是自定义的用户角色名称.
【使用指导】设备支持的每条命令执行时都需要相应的用户角色.
只有本命令中配置的用户角色具有权限,Schedule中的command命令中指定的命令行才能执行.
关于用户角色的详细描述请参见"基础配置指导"中的"RBAC".
同一Schedule最多可配置64个用户角色,超过该上限后,新配置会执行失败.
【举例】#配置执行定时任务test时使用的用户角色为rolename.
system-view[Sysname]schedulerscheduletest[Sysname-schedule-test]user-rolerolename【相关命令】commandschedulerschedule1.
1.
76xbarxbar命令用来配置主控板的负载模式.
【命令】(独立运行模式)xbar{load-balance|load-single}(IRF模式)xbarchassischassis-number{load-balance|load-single}【缺省情况】主控板的负载模式为load-balance.
【视图】系统视图【缺省用户角色】network-adminmdc-admin1-81【参数】chassischassis-number:用来配置指定成员设备上主用主控板和备用主控板的负载模式.
chassis-number表示设备在IRF中的成员编号.
(IRF模式)load-balance:设备的主用主控板和备用主控板共同参与报文的处理和转发.
load-single:只有主用主控板能处理和转发报文,备用主控板仅备份主用主控板的数据、监控主用主控板的状态.
【使用指导】当设备上只有一块主控板时,只支持load-single模式,即便配置了load-balance模式,主控板也会自动切换到load-single模式.
S7502E、S7503E-M设备不支持本命令.
对于安装了LSQM1SRP8X2QE0和LSQM2MPUD0主控板的设备,本命令配置后不生效.
【举例】#配置主用主控板和备用主控板的负载模式为load-balance.
(独立运行模式)system-view[Sysname]xbarload-balance【相关命令】displayxbar

百星数据(60元/月,600元/年)日本/韩国/香港cn2 gia云服务器,2核2G/40G/5M带宽

百星数据(baixidc),2012年开始运作至今,主要提供境外自营云服务器和独立服务器出租业务,根据网络线路的不同划分为:美国cera 9929、美国cn2 gia、香港cn2 gia、韩国cn2 gia、日本cn2 gia等云服务器及物理服务器业务。目前,百星数据 推出的日本、韩国、香港cn2 gia云服务器,2核2G/40G/5M带宽低至60元/月,600元/年。百星数据优惠码:优惠码:30...

Ftech:越南vps,2核/2G/20G SSD/1Gbps不限流量/可安装Windows系统,$12.5月

ftech怎么样?ftech是一家越南本土的主机商,成立于2011年,比较低调,国内知道的人比较少。FTECH.VN以极低的成本提供高质量服务的领先提供商之一。主营虚拟主机、VPS、独立服务器、域名等传统的IDC业务,数据中心分布在河内和胡志明市。其中,VPS提供1G的共享带宽,且不限流量,还可以安装Windows server2003/2008的系统。Ftech支持信用卡、Paypal等付款,但...

老用户专享福利 腾讯云 免费领取轻量云2核4G服务器一年

感恩一年有你!免费领取2核4G套餐!2核4G轻量应用服务器2核 CPU 4GB内存 60G SSD云硬盘 6Mbps带宽领取地址:https://cloud.tencent.com/act/pro/lighthousethankyou活动规则活动时间2021年9月23日 ~ 2021年10月23日活动对象腾讯云官网已注册且完成实名认证的国内站用户(协作者与子用户账号除外),且符合以下活动条件:账号...

系统空闲进程为你推荐
蓝色骨头手机谁有崔健执导的电影《蓝色的骨头》。李子柒年入1.6亿新晋网红李子柒是不是背后有团队是摆拍、炒作为的是人气、流量?www.4411b.com难道那www真的4411B坏了,还是4411b梗换com鑫域明了比肩工场比肩之意是什么意思长尾关键词挖掘工具大家是怎么挖掘长尾关键词的?haokandianyingwang谁给个好看的电影网站看看。mole.61.com摩尔庄园RK的秘密是什么?杨丽晓博客杨丽晓是怎么 出道的16668.com香港最快开奖现场直播今晚开www.hyyan.com请问我是HY了吗?在线等
免费域名注册 日本软银 荷兰服务器 香港主机 最好看的qq空间 京东商城0元抢购 qingyun adroit 1美金 电信托管 双线机房 空间登入 网页提速 便宜空间 海外空间 监控服务器 湖南idc 贵阳电信测速 畅行云 云销售系统 更多