DellOpenManagePowerCenter4.
1ReleaseNotesTopics:PriorityandrecommendationsCompatibilityNewinthisreleaseFixedissuesKnownissuesLimitationsInstallationinstructionsVersion4.
1Rev.
A00ReleasesummaryDellEMCOpenManagePowerCenter(OMPC)isapowermanagementsolutionforthedatacenter.
Itenablesyoutomonitorandmanagepowerconsumptionandtemperatureinyourdatacenterthroughthemanagementconsole.
PriorityandrecommendationsOPTIONAL:Dellrecommendsthecustomerreviewspecificsabouttheupdatetodetermineifitappliestoyoursystem.
Theupdatecontainschangesthatimpactonlycertainconfigurations,orprovidesnewfeaturesthatmay/maynotapplytoyourenvironment.
CompatibilityFollowingisthelistofsupportedDellplatforms,hardware,operatingsystems,andwebbrowsersinthisreleaseofPowerCenter:SupportedplatformsPowerEdgeR310ServerPowerEdgeR410ServerPowerEdgeR515ServerPowerEdgeR610ServerPowerEdgeR710ServerPowerEdgeR715ServerPowerEdgeR810ServerPowerEdgeR815ServerPowerEdgeR910ServerPowerEdgeM610ServerPowerEdgeM610xServerPowerEdgeM710ServerPowerEdgeM710HDServerPowerEdgeM910ServerPowerEdgeT610ServerPowerEdgeT710ServerRev.
A002018-09DellOpenManagePowerCenter4.
1ReleaseNotes1PowerEdgeFM120ServerPowerEdgeR320ServerPowerEdgeR420ServerPowerEdgeR520ServerPowerEdgeR620ServerPowerEdgeR720ServerPowerEdgeR720xdServerPowerEdgeR820ServerPowerEdgeR920ServerPowerEdgeM420ServerPowerEdgeM620ServerPowerEdgeM520ServerPowerEdgeT320ServerPowerEdgeT420ServerPowerEdgeT620ServerPowerEdgeR330ServerPowerEdgeR430ServerPowerEdgeR530ServerPowerEdgeR530XDServerPowerEdgeR630ServerPowerEdgeR730ServerPowerEdgeR730XdServerPowerEdgeR830ServerPowerEdgeR930ServerPowerEdgeR640ServerPowerEdgeR740ServerPowerEdgeR740XDServerPowerEdgeR840ServerPowerEdgeR940ServerPowerEdgeR940xaServerPowerEdgeM630ServerPowerEdgeM830ServerPowerEdgeT330ServerPowerEdgeT430ServerPowerEdgeT630ServerPowerEdgeFC430ServerPowerEdgeFC630ServerPowerEdgeFC830ServerPowerEdgeFD332ServerPowerEdgeC4130ServerPowerEdgeC6320ServerPowerEdgeC6420ServerPowerEdgeMX740CServerPowerEdgeMX840CServerPowerEdgeM1000eEnclosurePowerEdgeVRTXEnclosurePowerEdgeFX2/FX2sEnclosurePowerEdgeMX7000EnclosureSupportedhardware:Adual-coreprocessorof2.
6Ghzorhigher16GBRAM60GBfreespaceofharddriveGigabitbandwidthofnetworkinfrastructureSupportedoperatingsystems:MicrosoftWindowsServer2012R2EssentialsEditionMicrosoftWindowsServer2012R2StandardEdition2DellOpenManagePowerCenter4.
1ReleaseNotesMicrosoftWindowsServer2012R2DatacenterEditionMicrosoftWindowsServer2016StandardEditionMicrosoftWindowsServer2016DataCenterEditionMicrosoftWindows8.
1ProfessionalMicrosoftWindows8.
1EnterpriseMicrosoftWindows10ProfessionalRedHatEnterpriseLinux6.
9x86_64RedHatEnterpriseLinux7.
4RedHatEnterpriseLinux7.
5SUSELinuxEnterpriseServer11SP4x86_64SUSELinuxEnterpriseServer12SP3Supportedwebbrowsers:GoogleChrome63,64,and65MozillaFirefox57,58,and59MicrosoftInternetExplorer11MicrosoftEdgeNewinthisreleaseSupportfornewplatforms,operatingsystems,andbrowsers.
SupportforTripplitePDU.
Fordetailsonthepreviousrelease,seeOMPC4.
0ReleaseNotes.
FixedissuesIssue1:MisleadingerrormessageinPoweranalysispage.
Description:Whenyouselectagroupwithoutanyrackforpoweranalysis,theerrormessagedisplayedismisleading.
Rootcause:ThedifferenterrorcasesnotmappedtodifferenterrorcodesandOMPC4.
0cannotprovideerrorinformationindetailwhenthereisanunsupportedscenario.
Resolution:InOMPC4.
1,newerrormappingcodeisaddedandOMPCcanprovideclearerrorinfointhiscase.
KnownissuesIssue1:InconsistentpowerdataobservedforR640inIPMIandRedfishprotocol.
Description:ThereareminordifferencesintheR640dataobservedthroughtheIPMIandRedfishprotocols,asboththeprotocolsusedifferentsamplingintervalsforpowerreading.
Resolution:Itisrecommendedtouseoneprotocolatatimefordatacollectiontomaintainconsistencyindata.
LimitationsIssue1:Thepowergraphisblankwhileviewingthepower(ortemperature)history.
Description:Whenviewingthepowerhistory(ortemperature)ofaselectedgroupinthe15minute/1Hwindow,thegraphisblank.
Possiblecause:OpenManagePowerCenterhasjustbeeninstalledandhasnotcollectedenoughdatatoprovideapowerhistorygraph.
Resolutionorworkaround:ItisrecommendedtowaitasOpenManagePowerCentercollectsappropriatedatatopresentthegraph.
Issue2:ThoughIhaveeditedandsavedtheIPMIkey,thenexttimeIopenthesavedIPMIprofile,thekeyisonceagaindisplayedas0000….
Description:Thekeymighthavechanged,andtheyoumayhaveupdatedthevalue.
However,whilethedisplayshouldreadthevalueasxxxx…asthekeyisencrypted,theencryptedkeyisinsteaddisplayedas0000….
.
Thereisnodifferencebetweenthedisplay0000….
andxxxx….
Resolutionorworkaround:N/AIssue3:OMPCdoesnotprovideawarningwhenIdeletemyownLDAPaccount.
.
DellOpenManagePowerCenter4.
1ReleaseNotes3Description:IloggedintoOpenManagePowerCenterwithmyLDAPaccount,andthendeletedtheLDAPaccountintheusermanagementsettingsscreen,butOpenManagePowerCenterdidnotprovideawarningthatwasdeletingtheaccountIwasusingtologin.
Tobefixedinthesubsequentreleasewhichwillhaveawarningmessagetoensurethatyouawarethatyouaredeletingthecurrent-useraccount.
Resolutionorworkaround:LoginoraskpersonwithadminrightaccounttologintoOpenManagePowerCenterandcreatetheaccountifinfactyoumadeamistakeofdeletingtheaccount.
Issue4:ServercannoteditthepowerpolicyontheenclosureM1000e/VRTXfromstatictodynamic.
Description:OMPCsupportsstaticpowerpolicyforM1000e/VRTXatthechassislevel.
Duetothis,theoptionforselectingdynamicorstaticpowerpolicyisunavailable.
Resolutionorworkaround:SelectStaticpowerpolicyforM1000e/VRTX.
Issue5:Deviceselectionislostwhennavigatingtoanotherpage.
Description:ThisisaknownlimitationoftheOMPCUI.
TheUIonlyfocussesonthecurrentpage.
Anyactionssuchaseditordeleteneedtobetakenonthecurrentpagefortheselecteddevices.
Otherwise,theselectionwillbelostwhenyounavigatetothenextpage.
Resolutionorworkaround:Performtherecommendedtasksondevicesdisplayedonepageatatime.
Issue6:IgetanetworkexceptionerrorwhenIamtryingtologinwithanLDAPuseraccount.
Description:LDAPserverconfiguration(seeSettings>Directory)isrequiredtologinwithanLDAPuseraccount.
ThisissuecouldbecausedbythenetworkcommunicationbetweenLDAPandOMPCserverduringtheauthenticationprocess.
Resolutionorworkaround:ChecktheLDAPconfigurationinOpenManagePowerCentersettingtomakesuretheIPaddressofLDAPserveriscorrect.
Issue7:Thememorypowerisincorrectforsomedevicesinpowerhistorywindow.
Description:Thepowerhistorychartindevicepageshowsabnormalreading/spikesinmemorypower.
Resolutionorworkaround:UpdatetheiDRACfirmwaretolatesttosolvethisissue.
Issue8:PowercapabilitychangedfromMonitorandcappingtoNoneforT420ServerwhenweapplythetheiDRACfirmware2.
10.
10.
10.
Description:EventhoughT420serverhavethecappingcapability,itwillchangetoNoneifweapplyiDRACfirmware2.
10.
10.
10.
Resolutionorworkaround:UpdatetheiDRACfirmwaretolatesttosolvethisissue.
Issue9:SlotinfoofC6420isnotavailableifthedeviceisdiscoveredthroughRedfishprotocol.
Description:IfaC6420serverisaddedthroughRedfishprotocol,thereisnoRedfishcommandtogetitsslotnumberinchassis.
Resolutionorworkaround:Ifyouneedtoviewtheslotinformation,youcanremovethedeviceandre-discovertheserverthroughIPMIprotocol.
Issue10:Turningon"Lockdownmode"on14GserverswillimpactOMPCfunctionsofpowercappinganddevicelocationediting,iftheserverisdiscoveredbyRedfishprotocol.
Description:14thgenerationofPowerEdgeserversprovidedanewswitch"Lockdownmode"iniDRACconsole.
The"Lockdownmode"willlockdownallwriteoperationontheservers.
Turningon"Lockdownmode"on14GserverswillimpactOMPCfunctionsofpowercappinganddevicelocationediting.
TheseoperationsinOMPCwillfailwhenthe"Lockdownmode"isenabled.
Resolutionorworkaround:Turn-offthe"Lockdownmode"iniDRACconsoleifyouarediscoveringtheserverthroughRedfishprotocolorremovethedeviceandre-discovertheserverthroughIPMIprotocol.
Issue11:IfyouinstallOMPC4.
0orpriorversionswithapathdifferentfromthatofthedefaultpath(forexample,/opt/DELL/ompc)onLinuxoperatingsystemsandtrytorunthecommandrpm-UOpenManagePowerCenter.
rpmtoupgradetothelatestversion,anerrorisdisplayedandtheupgradeisnotsuccessful.
Description:Thisisalimitationintherpmtool.
Therpmtoolfails,ifthespecifiedpathisnotadefaultinstallationpathoftheolderversions.
Resolutionorworkaround:Itisrecommendedtoruntheinstall.
shtoupgradetoOMPC4.
1onLinuxoperatingsystemsoraddprefixparametertospecifythenon-defaultpathwhenusingrunrpm-Ucommand(forexample,rpm-UOpenManagePowerCenter.
rpm--prefix/opt/DELL/ompc1).
4DellOpenManagePowerCenter4.
1ReleaseNotesInstallationinstructionsInstallationprerequisitesDependenciesManagedserversmusthaveanIntegratedDellRemoteAccessController(iDRAC)6,7,or8.
Itisrecommendedtousethelatestversionfirmware.
PowerDistributionUnit(PDU)andUninterruptiblePowerSupply(UPS)devicesmustcomplywiththeManagementInformationBase(MIB)thevendorprovidesthroughSNMPinterface.
DevicesmustprovideexclusiveaccessforPowerCenterbecausethepoliciessetonthedevicesfromothermanagementsoftwareaffectthePowerCenterpowercontrolfunction.
TheBaseboardManagementController(BMC)user,throughwhichPowerCentercommunicateswithdevices,mustbealocaluseraccountwhoserolesincludeAdministrator.
ThedevicemustbeconfiguredtoallowtheAdministratortouseatleastoneoftheciphersuitelevels0–3,andenabletheIPMIoverLANsetting.
TheWSmanuser,throughwhichPowerCentercommunicateswiththechassis,mustbealocaluserwiththeAdministratorrole.
ThechassismustbeconfiguredtoenabletheWebServerservice.
Download1.
ClicktheDownloadFilelinktodownloadthefile.
2.
WhentheFileDownloadwindowappears,clickSavetosavethefiletoyourharddrive.
Extractfiles1.
Browsetothelocationwherethefileisdownloadedanddouble-clickthenewfiletounzipthedownloadedpackage.
2.
Specifythelocationtounzipthefiles.
3.
Clicktheunzipbuttontoextractthefiles.
InstallationBrowsetothelocationwherethefilesareunzippedandruntheapplication.
DellOpenManagePowerCenter4.
1ReleaseNotes5Notes,cautions,andwarningsNOTE:ANOTEindicatesimportantinformationthathelpsyoumakebetteruseofyourproduct.
CAUTION:ACAUTIONindicateseitherpotentialdamagetohardwareorlossofdataandtellsyouhowtoavoidtheproblem.
WARNING:AWARNINGindicatesapotentialforpropertydamage,personalinjury,ordeath.
2018DellInc.
oritssubsidiaries.
Allrightsreserved.
Dell,EMC,andothertrademarksaretrademarksofDellInc.
oritssubsidiaries.
Othertrademarksmaybetrademarksoftheirrespectiveowners.
2018-09Rev.
A00
弘速云元旦活动本公司所销售的弹性云服务器、虚拟专用服务器(VPS)、虚拟主机等涉及网站接入服务的云产品由具备相关资质的第三方合作服务商提供官方网站:https://www.hosuyun.com公司名:弘速科技有限公司香港沙田直营机房采用CTGNET高速回国线路弹性款8折起优惠码:hosu1-1 测试ip:69.165.77.50地区CPU内存硬盘带宽价格购买地址香港沙田2-8核1-16G20-...
Central美国独立日活动正在进行中,旗下美国达拉斯机房VPS 65折优惠,季付赠送双倍内存(需要发工单),Central租用的Hivelocity的机房,只支持信用卡和加密货币付款,不支持paypal,需要美国独服的可以谨慎入手试试。Central怎么样?Central便宜服务器,Central自称成立于2019年,主营美国达拉斯机房Linux vps、Windows vps、专用服务器和托管...
vpsdime怎么样?vpsdime是2013年注册的国外VPS主机商,实际上他还有一系列的其他域名站点如Winity.io, Backupsy,Cloudive, Virtora等等,母公司“Nodisto IT”相对来说还是很靠谱了的商家。VPSDime主要提供各种高配低价VPS套餐,其中Linux VPS和存储VPS基于OpenVZ架构,高级VPS基于KVM。VPSDime在上个季度的Low...
windowsserver2012为你推荐
海外虚拟主机请推荐下国外的虚拟主机?国内虚拟主机国内虚拟主机跟国外虚拟主机的区别?虚拟空间购买购买虚拟空间时怎么防止受骗域名服务商请问那些域名服务商是怎么捣鼓这么多域名的? 它们为什么可以做这个美国vps主机我用的美国VPS主机429元/月,感觉好贵,请问有比较便宜点的吗?香港虚拟空间最好的香港虚拟主机是哪家?免备案虚拟空间教你怎么看免备案虚拟主机空间php虚拟空间虚拟空间怎么修改php.ini配置深圳网站空间怎样申请免费网站空间虚拟主机管理系统如何用win虚拟主机管理系统搭建
网站空间价格 淘宝抢红包攻略 加勒比群岛 z.com gateone 鲜果阅读 阿里云代金券 论坛空间 主机合租 福建天翼加速 架设服务器 789电视网 国外代理服务器地址 联通网站 空间登录首页 万网空间管理 免费的asp空间 永久免费空间 成都主机托管 聚惠网 更多