DellOpenManagePowerCenter4.
1ReleaseNotesTopics:PriorityandrecommendationsCompatibilityNewinthisreleaseFixedissuesKnownissuesLimitationsInstallationinstructionsVersion4.
1Rev.
A00ReleasesummaryDellEMCOpenManagePowerCenter(OMPC)isapowermanagementsolutionforthedatacenter.
Itenablesyoutomonitorandmanagepowerconsumptionandtemperatureinyourdatacenterthroughthemanagementconsole.
PriorityandrecommendationsOPTIONAL:Dellrecommendsthecustomerreviewspecificsabouttheupdatetodetermineifitappliestoyoursystem.
Theupdatecontainschangesthatimpactonlycertainconfigurations,orprovidesnewfeaturesthatmay/maynotapplytoyourenvironment.
CompatibilityFollowingisthelistofsupportedDellplatforms,hardware,operatingsystems,andwebbrowsersinthisreleaseofPowerCenter:SupportedplatformsPowerEdgeR310ServerPowerEdgeR410ServerPowerEdgeR515ServerPowerEdgeR610ServerPowerEdgeR710ServerPowerEdgeR715ServerPowerEdgeR810ServerPowerEdgeR815ServerPowerEdgeR910ServerPowerEdgeM610ServerPowerEdgeM610xServerPowerEdgeM710ServerPowerEdgeM710HDServerPowerEdgeM910ServerPowerEdgeT610ServerPowerEdgeT710ServerRev.
A002018-09DellOpenManagePowerCenter4.
1ReleaseNotes1PowerEdgeFM120ServerPowerEdgeR320ServerPowerEdgeR420ServerPowerEdgeR520ServerPowerEdgeR620ServerPowerEdgeR720ServerPowerEdgeR720xdServerPowerEdgeR820ServerPowerEdgeR920ServerPowerEdgeM420ServerPowerEdgeM620ServerPowerEdgeM520ServerPowerEdgeT320ServerPowerEdgeT420ServerPowerEdgeT620ServerPowerEdgeR330ServerPowerEdgeR430ServerPowerEdgeR530ServerPowerEdgeR530XDServerPowerEdgeR630ServerPowerEdgeR730ServerPowerEdgeR730XdServerPowerEdgeR830ServerPowerEdgeR930ServerPowerEdgeR640ServerPowerEdgeR740ServerPowerEdgeR740XDServerPowerEdgeR840ServerPowerEdgeR940ServerPowerEdgeR940xaServerPowerEdgeM630ServerPowerEdgeM830ServerPowerEdgeT330ServerPowerEdgeT430ServerPowerEdgeT630ServerPowerEdgeFC430ServerPowerEdgeFC630ServerPowerEdgeFC830ServerPowerEdgeFD332ServerPowerEdgeC4130ServerPowerEdgeC6320ServerPowerEdgeC6420ServerPowerEdgeMX740CServerPowerEdgeMX840CServerPowerEdgeM1000eEnclosurePowerEdgeVRTXEnclosurePowerEdgeFX2/FX2sEnclosurePowerEdgeMX7000EnclosureSupportedhardware:Adual-coreprocessorof2.
6Ghzorhigher16GBRAM60GBfreespaceofharddriveGigabitbandwidthofnetworkinfrastructureSupportedoperatingsystems:MicrosoftWindowsServer2012R2EssentialsEditionMicrosoftWindowsServer2012R2StandardEdition2DellOpenManagePowerCenter4.
1ReleaseNotesMicrosoftWindowsServer2012R2DatacenterEditionMicrosoftWindowsServer2016StandardEditionMicrosoftWindowsServer2016DataCenterEditionMicrosoftWindows8.
1ProfessionalMicrosoftWindows8.
1EnterpriseMicrosoftWindows10ProfessionalRedHatEnterpriseLinux6.
9x86_64RedHatEnterpriseLinux7.
4RedHatEnterpriseLinux7.
5SUSELinuxEnterpriseServer11SP4x86_64SUSELinuxEnterpriseServer12SP3Supportedwebbrowsers:GoogleChrome63,64,and65MozillaFirefox57,58,and59MicrosoftInternetExplorer11MicrosoftEdgeNewinthisreleaseSupportfornewplatforms,operatingsystems,andbrowsers.
SupportforTripplitePDU.
Fordetailsonthepreviousrelease,seeOMPC4.
0ReleaseNotes.
FixedissuesIssue1:MisleadingerrormessageinPoweranalysispage.
Description:Whenyouselectagroupwithoutanyrackforpoweranalysis,theerrormessagedisplayedismisleading.
Rootcause:ThedifferenterrorcasesnotmappedtodifferenterrorcodesandOMPC4.
0cannotprovideerrorinformationindetailwhenthereisanunsupportedscenario.
Resolution:InOMPC4.
1,newerrormappingcodeisaddedandOMPCcanprovideclearerrorinfointhiscase.
KnownissuesIssue1:InconsistentpowerdataobservedforR640inIPMIandRedfishprotocol.
Description:ThereareminordifferencesintheR640dataobservedthroughtheIPMIandRedfishprotocols,asboththeprotocolsusedifferentsamplingintervalsforpowerreading.
Resolution:Itisrecommendedtouseoneprotocolatatimefordatacollectiontomaintainconsistencyindata.
LimitationsIssue1:Thepowergraphisblankwhileviewingthepower(ortemperature)history.
Description:Whenviewingthepowerhistory(ortemperature)ofaselectedgroupinthe15minute/1Hwindow,thegraphisblank.
Possiblecause:OpenManagePowerCenterhasjustbeeninstalledandhasnotcollectedenoughdatatoprovideapowerhistorygraph.
Resolutionorworkaround:ItisrecommendedtowaitasOpenManagePowerCentercollectsappropriatedatatopresentthegraph.
Issue2:ThoughIhaveeditedandsavedtheIPMIkey,thenexttimeIopenthesavedIPMIprofile,thekeyisonceagaindisplayedas0000….
Description:Thekeymighthavechanged,andtheyoumayhaveupdatedthevalue.
However,whilethedisplayshouldreadthevalueasxxxx…asthekeyisencrypted,theencryptedkeyisinsteaddisplayedas0000….
.
Thereisnodifferencebetweenthedisplay0000….
andxxxx….
Resolutionorworkaround:N/AIssue3:OMPCdoesnotprovideawarningwhenIdeletemyownLDAPaccount.
.
DellOpenManagePowerCenter4.
1ReleaseNotes3Description:IloggedintoOpenManagePowerCenterwithmyLDAPaccount,andthendeletedtheLDAPaccountintheusermanagementsettingsscreen,butOpenManagePowerCenterdidnotprovideawarningthatwasdeletingtheaccountIwasusingtologin.
Tobefixedinthesubsequentreleasewhichwillhaveawarningmessagetoensurethatyouawarethatyouaredeletingthecurrent-useraccount.
Resolutionorworkaround:LoginoraskpersonwithadminrightaccounttologintoOpenManagePowerCenterandcreatetheaccountifinfactyoumadeamistakeofdeletingtheaccount.
Issue4:ServercannoteditthepowerpolicyontheenclosureM1000e/VRTXfromstatictodynamic.
Description:OMPCsupportsstaticpowerpolicyforM1000e/VRTXatthechassislevel.
Duetothis,theoptionforselectingdynamicorstaticpowerpolicyisunavailable.
Resolutionorworkaround:SelectStaticpowerpolicyforM1000e/VRTX.
Issue5:Deviceselectionislostwhennavigatingtoanotherpage.
Description:ThisisaknownlimitationoftheOMPCUI.
TheUIonlyfocussesonthecurrentpage.
Anyactionssuchaseditordeleteneedtobetakenonthecurrentpagefortheselecteddevices.
Otherwise,theselectionwillbelostwhenyounavigatetothenextpage.
Resolutionorworkaround:Performtherecommendedtasksondevicesdisplayedonepageatatime.
Issue6:IgetanetworkexceptionerrorwhenIamtryingtologinwithanLDAPuseraccount.
Description:LDAPserverconfiguration(seeSettings>Directory)isrequiredtologinwithanLDAPuseraccount.
ThisissuecouldbecausedbythenetworkcommunicationbetweenLDAPandOMPCserverduringtheauthenticationprocess.
Resolutionorworkaround:ChecktheLDAPconfigurationinOpenManagePowerCentersettingtomakesuretheIPaddressofLDAPserveriscorrect.
Issue7:Thememorypowerisincorrectforsomedevicesinpowerhistorywindow.
Description:Thepowerhistorychartindevicepageshowsabnormalreading/spikesinmemorypower.
Resolutionorworkaround:UpdatetheiDRACfirmwaretolatesttosolvethisissue.
Issue8:PowercapabilitychangedfromMonitorandcappingtoNoneforT420ServerwhenweapplythetheiDRACfirmware2.
10.
10.
10.
Description:EventhoughT420serverhavethecappingcapability,itwillchangetoNoneifweapplyiDRACfirmware2.
10.
10.
10.
Resolutionorworkaround:UpdatetheiDRACfirmwaretolatesttosolvethisissue.
Issue9:SlotinfoofC6420isnotavailableifthedeviceisdiscoveredthroughRedfishprotocol.
Description:IfaC6420serverisaddedthroughRedfishprotocol,thereisnoRedfishcommandtogetitsslotnumberinchassis.
Resolutionorworkaround:Ifyouneedtoviewtheslotinformation,youcanremovethedeviceandre-discovertheserverthroughIPMIprotocol.
Issue10:Turningon"Lockdownmode"on14GserverswillimpactOMPCfunctionsofpowercappinganddevicelocationediting,iftheserverisdiscoveredbyRedfishprotocol.
Description:14thgenerationofPowerEdgeserversprovidedanewswitch"Lockdownmode"iniDRACconsole.
The"Lockdownmode"willlockdownallwriteoperationontheservers.
Turningon"Lockdownmode"on14GserverswillimpactOMPCfunctionsofpowercappinganddevicelocationediting.
TheseoperationsinOMPCwillfailwhenthe"Lockdownmode"isenabled.
Resolutionorworkaround:Turn-offthe"Lockdownmode"iniDRACconsoleifyouarediscoveringtheserverthroughRedfishprotocolorremovethedeviceandre-discovertheserverthroughIPMIprotocol.
Issue11:IfyouinstallOMPC4.
0orpriorversionswithapathdifferentfromthatofthedefaultpath(forexample,/opt/DELL/ompc)onLinuxoperatingsystemsandtrytorunthecommandrpm-UOpenManagePowerCenter.
rpmtoupgradetothelatestversion,anerrorisdisplayedandtheupgradeisnotsuccessful.
Description:Thisisalimitationintherpmtool.
Therpmtoolfails,ifthespecifiedpathisnotadefaultinstallationpathoftheolderversions.
Resolutionorworkaround:Itisrecommendedtoruntheinstall.
shtoupgradetoOMPC4.
1onLinuxoperatingsystemsoraddprefixparametertospecifythenon-defaultpathwhenusingrunrpm-Ucommand(forexample,rpm-UOpenManagePowerCenter.
rpm--prefix/opt/DELL/ompc1).
4DellOpenManagePowerCenter4.
1ReleaseNotesInstallationinstructionsInstallationprerequisitesDependenciesManagedserversmusthaveanIntegratedDellRemoteAccessController(iDRAC)6,7,or8.
Itisrecommendedtousethelatestversionfirmware.
PowerDistributionUnit(PDU)andUninterruptiblePowerSupply(UPS)devicesmustcomplywiththeManagementInformationBase(MIB)thevendorprovidesthroughSNMPinterface.
DevicesmustprovideexclusiveaccessforPowerCenterbecausethepoliciessetonthedevicesfromothermanagementsoftwareaffectthePowerCenterpowercontrolfunction.
TheBaseboardManagementController(BMC)user,throughwhichPowerCentercommunicateswithdevices,mustbealocaluseraccountwhoserolesincludeAdministrator.
ThedevicemustbeconfiguredtoallowtheAdministratortouseatleastoneoftheciphersuitelevels0–3,andenabletheIPMIoverLANsetting.
TheWSmanuser,throughwhichPowerCentercommunicateswiththechassis,mustbealocaluserwiththeAdministratorrole.
ThechassismustbeconfiguredtoenabletheWebServerservice.
Download1.
ClicktheDownloadFilelinktodownloadthefile.
2.
WhentheFileDownloadwindowappears,clickSavetosavethefiletoyourharddrive.
Extractfiles1.
Browsetothelocationwherethefileisdownloadedanddouble-clickthenewfiletounzipthedownloadedpackage.
2.
Specifythelocationtounzipthefiles.
3.
Clicktheunzipbuttontoextractthefiles.
InstallationBrowsetothelocationwherethefilesareunzippedandruntheapplication.
DellOpenManagePowerCenter4.
1ReleaseNotes5Notes,cautions,andwarningsNOTE:ANOTEindicatesimportantinformationthathelpsyoumakebetteruseofyourproduct.
CAUTION:ACAUTIONindicateseitherpotentialdamagetohardwareorlossofdataandtellsyouhowtoavoidtheproblem.
WARNING:AWARNINGindicatesapotentialforpropertydamage,personalinjury,ordeath.
2018DellInc.
oritssubsidiaries.
Allrightsreserved.
Dell,EMC,andothertrademarksaretrademarksofDellInc.
oritssubsidiaries.
Othertrademarksmaybetrademarksoftheirrespectiveowners.
2018-09Rev.
A00
青云互联怎么样?青云互联是一家成立于2020年的主机服务商,致力于为用户提供高性价比稳定快速的主机托管服务,目前提供有美国免费主机、香港主机、韩国服务器、香港服务器、美国云服务器,香港安畅cn2弹性云限时首月五折,15元/月起;可选Windows/可自定义配置,让您的网站高速、稳定运行。点击进入:青云互联官方网站地址青云互联优惠码:八折优惠码:ltY8sHMh (续费同价)青云互联香港云服务器活动...
官方网站:点击访问90IDC官方网站优惠码:云八五折优惠劵:90IDCHK85,仅适用于香港CLOUD主机含特惠型。活动方案:年付特惠服务器:CPU均为Intel Xeon两颗,纯CN2永不混线,让您的网站更快一步。香港大浦CN2測速網址: http://194.105.63.191美国三网CN2測速網址: http://154.7.13.95香港购买地址:https://www.90idc.ne...
俄罗斯vps速度怎么样?俄罗斯vps云主机节点是欧洲十大节点之一,地处俄罗斯首都莫斯科,网络带宽辐射周边欧洲大陆,10G专线连通德国法兰克福、法国巴黎、意大利米兰等,向外连接全球。俄罗斯vps云主机速度快吗、延迟多少?由于俄罗斯数据中心出口带宽充足,俄罗斯vps云主机到全球各地的延迟、速度相对来说都不错。今天,云服务器网(yuntue.com)小编介绍一下俄罗斯vps速度及俄罗斯vps主机推荐!俄...
windowsserver2012为你推荐
vps虚拟主机请通俗解析一下虚拟主机,VPS和云主机?它们各有什么用途?免费云主机永久免费的云主机哎或者空间或者vps免费网站域名申请怎么免费上传我的网站呀和免费申请域名查询ip怎样查别人的ip地址?网站空间域名网站制作 域名和空间域名申请申请域名需要什么条件?具体点!急!急!!!网站空间商网站空间商怎么查询asp网站空间什么是ASP空间?网站空间价格1M网站空间是多少钱韩国虚拟主机香港和韩国的虚拟主机哪个比较好?
网站域名备案 免费com域名申请 godaddy域名解析 如何注册中文域名 七牛优惠码 google镜像 主机测评网 bluevm godaddy续费优惠码 美国十次啦服务器 合租空间 东莞数据中心 中国电信宽带测速网 免费网页申请 电信托管 银盘服务 独享主机 云服务是什么意思 双11促销 windowssever2008 更多