服务器DIY机柜选购服务器机柜导购Server cabinet purchasing server cabinet guide

If you follow the following check order, you can choose not only conforms to the installation of your priorities, including safety, durability, compatibility and easy to loading and unloading) , cabinets and not beyond your budget. . .

To telecom data center rental cabinets or just rent space cabinet intermediate 1 u, 2 u, believe everyone understand better how one thing, however, some of the telecom room not only provide cabinets leasing service, even can also provide room rent, is part of the user to sign the room space, rooms ISP to provide users with access lines and power supply, refrigeration facilities condition, this kind of business is generally to large users, customers only need to tell room operators, the specific requirements for operator, tailored, can be flexible wiring, and network configuration for the client, good nature is charging flexible, let customers don't need to spend big self-built room can enjoy top equipment room is comfortable and smooth, the placement of the most important still is the customer free cabinets and equipment needed for yourself!However, if your choice of network cabinet is not appropriate,install the most valuable part of the installation--the server will be installed in the cabinet, and you will find that there is little room left for the cabinet. On the contrary, if you follow the following check order, you can choose not only conforms to the installation of your priorities, including safety, durability, compatibility and easy to loading and unloading) , cabinets and not beyond your budget. The first

consideration should be security. Putting IT equipment into a locked cabinet will make IT easier for network administrators to limit the number of people who can open the cabinet.Physical requirement

List all the equipment installed in the cabinet and their complete measurements: high, long, wide and heavy. The total height of these devices will ultimately determine how much equipment can be loaded into the cabinet. Obviously, high cabinets can fit into more equipment and are more efficient.Of course, use the height of the cabinet is not the only consideration, the rear of the cabinet also has a lot of place to use. That' s why you're measuring the depth of the machine.Choose a deep cabinet, can install two sets of equipment back to back, install more equipment thereby. In this way, two rows of equipment can be loaded in the cabinet, one row from the front door of the cabinet and the other from the back door. The cabinet should be adjustable.

After calculating the cabinet space (in "U" or 1.75 inches) ,consider the size of the room. You don' t want to see the cabinets stuffed up and soon find that you have to put in some more equipment. Once you buy and install the cabinets, these extra devices tend to come up. Therefore, as a basic principle, the cabinet height should be 20% to 30%more for system expansion.These Spaces also improve the ventilation conditions of the equi pment.

The device with a bracket does not need to consider the width

because it is designed according to the width of the cabinet.But for the server and other peripherals that cannot be installed, the width cannot be ignored.

Since the total weight of the equipment is often not light, you should choose a cabinet that can hold about 1500 pounds. That is to say, you should select a strong and strong cabinet. In the cabinet,

The weight of the device determines whether the selection of the sliding frame is standard or heavier, and the selection of other accessories is also determined. Select the cabinet that is 100% compatible with all servers, and it should meet or exceed the third bracket standard of all OEM manufacturers. If youwant to install tower or desktop devices, sliding racks and installing attachments are required.

Due to the installation of network cables, telecommunication cables and power cables, you need to purchase the belt or belt of the belt to effectively keep the cable in the cabinet. If the cabinet is equipped with a cable management module, the cable can be fixed directly in the vertical mounting rail. In either case, the upper wall and the side wall of the cabinet should have enough fixed rings (to protect the cables) , or they canbe carried on the bottom of the cabinet so that the following line can be taken.

Cabinet type and class

Although cabinet looks almost the same, but different segmentationup according to its use and there are several types

of common is used for wiring rack and is used to put the racks of servers, used for wiring rack is usually used to place more than one terminal switches, so there will be a lot of cable need to pick up, cabinet is not convenient to get a door, so that the rack looks more like rack, also had a cabinet manufacturer called this product wiring; In addition to the server racks are certainly a door have a lock, because to protect valuable equipment inside, so the more expensive the routers, firewalls,general is on the rack.

For server cabinets, there are also grades:

Common server cabinet

This is a normal server rack, glass door, the server rack cooling fan has four, installed at the top of the rack, mainly used for ventilation cooling purposes, provide a good constant temperature environment for the inside of a cabinet, cabinet is at the bottom of the hollow out, used for ventilation and heat dissipation. The server at the top of the cabinet has very good heat dissipation, but the lower part of the server is not very good at heat dissipation.

Advanced server cabinet

Above this kind of rack is relatively high-end server rack,thickly dotted on the QianHouMen wind hole for ventilation and heat dissipation, so the roomair conditioningair conditioning can be a very good distribution within each server around to the cabinet, the cabinet of the cooling effect is good, and this kind of rack materials standards, anticorrosion, bearing

capacity is strong.

Key component

In addition to the server need to be protected, don't forget to still have some parts need to load the cabinets - network equipment (hubs, routers, distribution frame, the keyboard/mouse/display sharing, tape drives, and storage) and peripherals (monitor, keyboard, modem) .

The most critical component is the power protector. In various installations, all servers should be protected by a continuous power supply system. Even if the device takes up the space of 1U, it needs to be protected. Even devices that do not require continuous operation should be protected by an electric surge suppressor or linear regulator, which is available in the installation configuration.

Don' t forget the power parts, such as a power socket. If you don' t want a dozen power lines to reach out of the rack,You can use apower socket. Although you can use the power socket of the 1U support model, the power socket bar can be installed in any corner of the inner wall of the cabinet to make room for other devices. Remember, any component that cannot mount a bracket requires additional pallets, support accessories, and other installers.

Next, addupall theheat generated by the device to be installed.A 45U cabinet, which is well ventilated at the top and bottom,allows for an average of 3,000 to 5000BTUs total calories. If

the total number of calories exceeds the maximum number of calories in the cabinet, you will need to purchase a fan that can be installed on the wall or side wall of the cabinet. The upper wall fan is more expensive, but the effect is installed on the side wall twice. The side wall fan should be installed in the back wall of the cabinet, since the rear of the device generates most of the heat.

Installation attention

With the relevant dimensions of the cabinet, check the shape of the equipment to ensure the matching of the bracket. A sturdy cabinet can carry up to 450 pounds, so check out the tools used to take out the equipment, such as a lift door or a trolley.A good cabinet is equipped with wheels, so you can simply pack the equipment and push it to the right place.

Measure the size of the room and the height of the ceiling, door and elevator. In addition, considering the multi-class equipment in the cabinet, make sure to place the cabinet in a place close to the power supply, cable socket and communication socket.

Check the Angle of the cabinet door when opening and closing the cabinet. The standard cabinet door opens on the right, the door axis on the left, and of course not the other way around.All doors and side panels should be easily opened for maintenance.

When you want to install the device cabinet in an existing cabinet unit, you can place the cabinets in arow, safe and tidy.

However, some cabinets cannot be added for a variety of reasons,or can only add several attachments. The best cabinet group model should be fully expandable and with all the necessary hardware, remove the side panels of the cabinet, connect the cabinet with screws, and arrange them in a row.

Price factor

Prices always have to be considered, but they can't be sacrificed for important features. Need to choose the most cost-effective cabinet. Servers and peripherals change quickly,but good cabinets take a long time. Comparing the advantages and disadvantages of the cabinet, the key is to compare several recognized performance indicators. In performance metrics, pay attention to the word "attach", which indicates that it is allowed to be extended at any time. Many vendors give you only see cabinet unit price, not including cabinets shall be installed in the equipment price, and the equipment can make your spending quickly become bigger, so you have to consider cabinets plus a full set of equipment price, don't at the meeting by the manufacturer.

Finally, select the manufacturer of the production cabinet. The service life is recognized as a performance standard, and the manufacturer should have a department to help you install the cabinet, install the equipment properly, and provide you with the accessories within a few years after the sale. Also, make sure the manufacturer offers a lifetime maintenance of the cabinet.

vdsina:俄罗斯VPS(datapro),6卢布/天,1G内存/1核(AMD EPYC 7742)/5gNVMe/10T流量

今天获得消息,vdsina上了AMD EPYC系列的VDS,性价比比较高,站长弄了一个,盲猜CPU是AMD EPYC 7B12(经过咨询,详细CPU型号是“EPYC 7742”)。vdsina,俄罗斯公司,2014年开始运作至今,在售卖多类型VPS和独立服务器,可供选择的有俄罗斯莫斯科datapro和荷兰Serverius数据中心。付款比较麻烦:信用卡、webmoney、比特币,不支持PayPal...

半月湾($59.99/年),升级带宽至200M起步 三网CN2 GIA线路

在前面的文章中就有介绍到半月湾Half Moon Bay Cloud服务商有提供洛杉矶DC5数据中心云服务器,这个堪比我们可能熟悉的某服务商,如果我们有用过的话会发现这个服务商的价格比较贵,而且一直缺货。这里,于是半月湾服务商看到机会来了,于是有新增同机房的CN2 GIA优化线路。在之前的文章中介绍到Half Moon Bay Cloud DC5机房且进行过测评。这次的变化是从原来基础的年付49....

酷锐云香港(19元/月) ,美国1核2G 19元/月,日本独立物理机,

酷锐云是一家2019年开业的国人主机商家,商家为企业运营,主要销售主VPS服务器,提供挂机宝和云服务器,机房有美国CERA、中国香港安畅和电信,CERA为CN2 GIA线路,提供单机10G+天机盾防御,提供美国原生IP,支持媒体流解锁,商家的套餐价格非常美丽,CERA机房月付20元起,香港安畅机房10M带宽月付25元,有需要的朋友可以入手试试。酷锐云自开业以来一直有着良好的产品稳定性及服务态度,支...

服务器导购为你推荐
国外域名注册如何注册国外域名?域名备案域名怎么备案成都虚拟空间五星网络隶属于成都冠一科技有限公司,虚拟空间购买了不到一个月不能访问2次,质量真差啊!网站空间购买不用备案的网站空间,哪里可以有这样的网站空间购买?网站空间商网站备案为什么是空间商备案?求解虚拟主机软件谁知道这个虚拟机软件叫什么。虚拟主机服务商请问哪个服务商的虚拟主机比较好呀山东虚拟主机济宁梦网科技mysql虚拟主机如何建立支持PHP+MySQL的虚拟主机?美国虚拟主机购买美国虚拟主机如何购买
linux虚拟主机 免费网站域名申请 vps优惠码 com域名抢注 免费高速空间 华为云盘 raid10 smtp服务器地址 工信部网站备案查询 lamp架构 免费php空间 聚惠网 免费的加速器 服务器机柜 web服务器有哪些 nic linuxvi 饭桶 nano 电脑主机声音大 更多